coated membrane
Recently Published Documents


TOTAL DOCUMENTS

173
(FIVE YEARS 42)

H-INDEX

29
(FIVE YEARS 7)

Author(s):  
Shohei Hamabe ◽  
Shinji Tawara ◽  
Syouhei Nishihama ◽  
Kazuharu Yoshizuka
Keyword(s):  

Desalination ◽  
2021 ◽  
Vol 517 ◽  
pp. 115242
Author(s):  
Shima Ghorabi ◽  
Farzin Zokaee Ashtiani ◽  
Mohammad Karimi ◽  
Amir Fouladitajar ◽  
Bahareh Yousefi ◽  
...  

2021 ◽  
Vol 12 (4) ◽  
pp. 165
Author(s):  
Wenxuan Ji ◽  
Sen Wang ◽  
Yongwen Sun ◽  
Hong Lv ◽  
Xiaojun Shen ◽  
...  

The membrane electrode assembly was prepared by a catalyst coated membrane (CCM) with an effective active area of 10 × 10 cm2 in this work. Porous titanium plates with different diameters were used as anode collectors to study the polarization curve and electrochemical impedance spectroscopy (EIS) of the electrolyzer. The results show that the pore size of a porous titanium plate on the anode side has a significant effect on the performance of the electrolyzer. The best cell performance was obtained when the median diameter of the anode titanium plate was 12.3 um. When the current density is 1 A/cm2, the battery voltage is 2.253 V.


2021 ◽  
Author(s):  
Sewoon Kim ◽  
Farivash Gholamirad ◽  
Bora Shin ◽  
Nader Taheri-Qazvini ◽  
Jinwoo Cho ◽  
...  

2021 ◽  
Vol 5 (1) ◽  
pp. 69
Author(s):  
Mashuni Mashuni ◽  
Halimahtussaddiyah Ritonga ◽  
Muhammad Jahiding ◽  
La Ode Ahmad Nur Ramadhan ◽  
Desy Kurniawati ◽  
...  

The need to control pesticide residues in foodstuffs in a fast and straightforward analysis for the field scale is required. Therefore, this research develops a transducer-based biosensor with a small device potentiometer (SDP) to produce a fast and accurate pesticide detection tool. The biosensor based on Au electrodes by immobilizing the acetylcholinesterase (AChE) enzyme coated membrane cellulose acetate (CA) 15% (w/v) cross-linked glutaraldehyde (GA) 25% (v/v) and SDP as a transducer that produces a potential value. The biosensor testing results on the organophosphate pesticide class, namely diazinon and profenofos, showed the sensitivity of 21.204 and 20.035 mV decade−1, Limit of Detection (LoD) 10−7 mg L−1, selectivity coefficient −1 < Ki,j < 1 and accuracy of 99.497 and 94.765%, respectively. The results showed that the biosensor connected to an SDP transducer had an excellent performance in determining the presence of organophosphate pesticides.


2021 ◽  
Vol 85 ◽  
pp. 100924
Author(s):  
Kläre Christmann ◽  
K. Andreas Friedrich ◽  
Nada Zamel

Author(s):  
Sarah Lotfikatouli ◽  
Pejman Hadi ◽  
Mengying Yang ◽  
Harold W. Walker ◽  
Benjamin S. Hsiao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document