ISRN Radiology
Latest Publications


TOTAL DOCUMENTS

39
(FIVE YEARS 0)

H-INDEX

13
(FIVE YEARS 0)

Published By Hindawi (International Scholarly Research Network)

2314-4084

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Ruken Yuksekkaya ◽  
Levent Aggunlu ◽  
Yusuf Oner ◽  
Halil Celik ◽  
Sergin Akpek ◽  
...  

Magnetic resonance imaging is the most important diagnostic method in the investigation of the pituitary lesions. Our aim is to determine whether T2-weighted coronal images may be helpful in the evaluation of the pituitary gland with suspected pituitary adenomas. One hundred and sixty-seven patients were examined prospectively with T2-weighted coronal and T1-weighted coronal images enhanced with intravenous contrast material. The images were evaluated for the presence, the size, the location, and the ancillary signs including sellar floor erosion or ballooning, infindibulary deviation, convexity of the superior border of the gland, diffuse enlargement of the gland, and the invasion of the cavenous sinuses on both images. In forty-six (28%) patients lesions were revealed on both sequences. In twenty-one (12%) patients the lesions that were revealed on the T1-weighted images were not detected on the T2-weighted images. Positive predictive value, negative predictive value, sensitivity, specificity, and diagnostic accuracy rates of T2-weighted coronal images on the detection of the presence of lesions were 100%, 17.4%, 68.7%, 100%, and 87.4%, respectively. Both T2-weighted coronal and T1-weighted coronal images enhanced with intravenous gadolinium-based contrast material are important in the diagnosis of pituitary adenomas. T2-weighted coronal images could be used as a screening tool for the primary evaluation of the pituitary gland.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Aneel Kumar Vaswani ◽  
Waseem Mehmood Nizamani ◽  
Muhammad Ali ◽  
Geeta Aneel ◽  
Bhesham Kumar Shahani ◽  
...  

Purpose. To determine the diagnostic accuracy of contrast enhanced FLAIR sequence of MRI brain in the diagnosis of meningitis. Subjects and Methods. A prospective study of 57 patients with signs and symptoms of meningitis, referred to the radiology department for MRI examination. Out of these, there were 30 males and 27 females. They underwent MRI brain with contrast including postcontrast T1W and FLAIR sequences. Cerebrospinal fluid (CSF) analysis obtained by lumbar puncture after MRI was considered the “reference standard” against which MRI findings were compared. Results. Of 57 patients, 50 were diagnosed as having meningitis on subsequent CSF analysis. Out of these 50, 49 were positive on postcontrast FLAIR images and 34 were positive on postcontrast T1W images. One patient was labeled false positive as CSF analysis showed malignant cells (leptomeningeal carcinomatosis). In the diagnosis of meningitis, the sensitivity of postcontrast FLAIR sequence was 96% and specificity 85.71%, whereas the sensitivity of postcontrast T1W sequence was 68% and specificity 85.71%. Conclusion. Contrast-enhanced FLAIR sequence is more sensitive and specific than contrast-enhanced T1W sequence in the diagnosis of meningitis. It should be routinely used in suspected cases of meningitis.


2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Maryam Rahiminejad ◽  
Anshul Rastogi ◽  
Shirish Prabhudesai ◽  
David Mcclinton ◽  
Peter MacCallum ◽  
...  

Aims. Colour doppler ultrasonography (CDUS) is widely used in the diagnosis of deep venous thrombosis (DVT); however, the number of scans positive for above knee DVT is low. The present study evaluates the reliability of the D-dimer test combined with a clinical probability score (Wells score) in ruling out an above knee DVT and identifying patients who do not need a CDUS. Materials and Method. This study is a retrospective audit and reaudit of a total of 816 outpatients presenting with suspected lower limb DVT from March 2009 to March 2010 and from September 2011 to February 2012. Following the initial audit, a revised clinical diagnostic pathway was implemented. Results. In our initial audit, seven patients (4.9%) with a negative D-dimer and a low Wells score had a DVT. On review, all seven had a risk factor identified that was not included in the Wells score. No patient with negative D-dimer and low Wells score with no extra clinical risk factor had a DVT on CDUS (negative predictive value 100%). A reaudit confirmed adherence to our revised clinical diagnostic pathway. Conclusions. A negative D-dimer together with a low Wells score and no risk factors effectively excludes a lower limb DVT and an ultrasound is unnecessary in these patients.


2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Lukas Ebner ◽  
Harald M. Bonel ◽  
Adrian Huber ◽  
Steffen Ross ◽  
Andreas Christe

Objective. To evaluate the diagnostic benefit of real-time elastography (RTE) in clinical routine. Strain indices (SI) for benign and malignant tumors were assessed. Methods. 100 patients with 110 focal breast lesions were retrieved. Patients had mammography (MG), ultrasound (US), and, if necessary, MRI. RTE was conducted after ultrasound. Lesions were assessed with BI-RADS for mammography and ultrasound. Diagnosis was established with histology or follow-up. Results. SI for BI-RADS 2 was 1.71±0.86. Higher SI (2.21±1.96) was observed for BI-RADS 3 lesions. SI of BI-RADS 4 and 5 lesions were significantly higher 16.92±20.89 and 19.54±10.41. 31 malignant tumors exhibited an average SI of 16.13±14.67; SI of benign lesions was 5.29±11.87 (P value <0.0001). ROC analysis threshold was >3.8 for malignant disease. Sensitivity of sonography was 90.3% (specificity 78.5%). RTE showed a sensitivity of 87.1% (specificity 79.7%). Accuracy of all modalities combined was 96.8%. In BI-RADS 3 lesions RTE was able to detect all malignant lesions (sensitivity 100%, specificity 92.9%, and accuracy 93.9%). Conclusions. RTE increased sensitivity and specificity for breast cancer detection when used in combination with ultrasound.


2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
L. Margolies ◽  
A. Cohen ◽  
E. Sonnenblick ◽  
J. Mandeli ◽  
P. H. Schmidt ◽  
...  

Objectives. To study factors that predict changes in management with digital breast tomosynthesis (DBT). Methods. The Institutional Review Board approved this HIPAA compliant study. 996 patients had DBT with full field digital mammography (FFDM). Univariate analysis evaluated predictors of management change and cancer detection. Results. DBT changed management in 109 of 996 (11%); 77 (71%) required less imaging. Recalled patients after abnormal FFDM screen were most likely to have management change—25% (24 of 97 patients) compared to 8% (13/163) of symptomatic patients and 10% (72/736) of screening patients (P<0.001). Dense breasted patients had a higher likelihood of having DBT change management: 13% (68/526) compared to 9% (41/470) (P=0.03). Of the 996 patients, 19 (2%) were diagnosed with breast cancer. 15 cancers (83%) were seen on FFDM and DBT; 3 (17%) were diagnosed after DBT (0.3%, 95%CI: 0.1–0.9%). One recurrence was in the skin and was not seen on DBT nor was it seen on FFDM. The increase in cancer detection rate was 17% for asymptomatic patients, 0% for symptomatic patients, and 100% for recalled patients. Conclusions. DBT increased cancer detection rate by 20% and decreased the recall rate in 8–25%. Advances in Knowledge. DBT led to a doubling of the cancer detection rate in recalled patients.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Shayan Sirat Maheen Anwar ◽  
Zahid Anwar Khan ◽  
Rana Shoaib Hamid ◽  
Fahd Haroon ◽  
Raza Sayani ◽  
...  

Purpose. To determine association between apparent diffusion coefficient value on diffusion-weighted imaging and Gleason score in patients with prostate cancer. Methods. This retrospective case series was conducted at Radiology Department of Aga Khan University between June 2009 and June 2011. 28 patients with biopsy-proven prostate cancer were included who underwent ultrasound guided sextant prostate biopsy and MRI. MRI images were analyzed on diagnostic console and regions of interest were drawn. Data were entered and analyzed on SPSS 20.0. ADC values were compared with Gleason score using one-way ANOVA test. Results. In 28 patients, 168 quadrants were biopsied and 106 quadrants were positive for malignancy. 89 lesions with proven malignancy showed diffusion restriction. The mean ADC value for disease with a Gleason score of 6 was 935 mm2/s (SD=248.4 mm2/s); Gleason score of 7 was 837 mm2/s (SD=208.5 mm2/s); Gleason score of 8 was 614 mm2/s (SD=108 mm2/s); and Gleason score of 9 was 571 mm2/s (SD=82 mm2/s). Inverse relationship was observed between Gleason score and mean ADC values. Conclusion. DWI and specifically quantitative ADC values may help differentiate between low-risk (Gleason score, 6), intermediate-risk (Gleason score, 7), and high-risk (Gleason score 8 and 9) prostate cancers, indirectly determining the aggressiveness of the disease.


2014 ◽  
Vol 2014 ◽  
pp. 1-16 ◽  
Author(s):  
Marco Francone

Dilated cardiomyopathy (DCM) represents the final common morphofunctional pathway of various pathological conditions in which a combination of myocyte injury and necrosis associated with tissue fibrosis results in impaired mechanical function. Recognition of the underlying aetiology of disease and accurate disease monitoring may be crucial to individually optimize therapeutic strategies and stratify patient’s prognosis. In this regard, CMR has emerged as a new reference gold standard providing important information for differential diagnosis and new insight about individual risk stratification. The present review article will focus on the role of CMR in the evaluation of present condition, analysing respective strengths and limitations in the light of current literature and technological developments.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Ayse Aralasmak ◽  
Kamil Karaali ◽  
Can Cevikol ◽  
Utku Senol ◽  
Timur Sindel ◽  
...  

Purpose. The carotid-cavernous fistula (CCF) is an abnormal arteriovenous communication and its drainage pathways may affect the clinic presentation and change treatment approach. We evaluated drainage patterns of CCFs by digital subtraction angiography (DSA) and categorized drainage pathways according to their types and etiology. Materials and Methods. Venous drainage patterns of 13 CCFs from 10 subjects were studied and categorized as anterior, posterior, superior, inferior, and contralateral on DSA. Drainage patterns were correlated to types and etiology of CCFs. Diagnosis of CCFs was first made by noninvasive imaging techniques. Results. On DSA, traumatic CCFs were usually high flow, direct type while spontaneous CCFs were usually slow flow, indirect type. Bilaterality and mixed types were observed among the indirect spontaneous CCFs. In all CCFs, anterior and inferior drainages were the most common. Contrary to the literature, posterior and superior drainages were noted only in high flow and long standing direct fistulas. Contralateral drainage was not observed in all, supporting plausible compartmentalization of cavernous sinuses. Conclusion. Types, etiology, and duration of the CCFs may affect their drainage patterns. DSA is valuable for categorization of CCFs and verification of drainage patterns. Drainage pathways may affect the clinic presentation and also change treatment approach.


2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Subhash Kumar ◽  
Shailesh B. Gaikwad ◽  
Nalini Kant Mishra

Introduction. 3D Rotational Angiography (RA) is indispensable for evaluation of intracranial aneurysms, providing infinite viewing angles and defining the aneurysm morphology. Its role in follow-up of clipped aneurysms remains unclear. We aimed to compare the aneurysm residue/recurrence detection rate of 3D RA with 2D digital subtraction angiography (DSA). Methods. 47 patients harboring 54 clipped aneurysms underwent both 2D DSA and 3D RA. The residual/recurrent aneurysms were classified into five grades and the images of both modalities were compared. Results. The residual/recurrent aneurysm detection rate was 53.70% (29/54 aneurysms) with 2D DSA and 66.67% (36/54 aneurysms) with 3D RA (P=0.05). In 12 aneurysms, 3D RA upgraded the residue/recurrence among which nine had been completely not detected on 2D DSA and were found to have grade one or two residual necks on the 3D RA, and, in three cases, a small neck on 2D DSA turned out to be aneurysm sac on 3D RA. In a total of 5 aneurysms, the classification was downgraded by 3D RA. Conclusion. 3D RA picks up more aneurysm residue/recurrence; hence, both 2D DSA and 3D RA should be performed in follow-up evaluation of clipped aneurysms.


2013 ◽  
Vol 2013 ◽  
pp. 1-4 ◽  
Author(s):  
Revant H. Chole ◽  
Ranjitkumar N. Patil ◽  
Swati Balsaraf Chole ◽  
Shailesh Gondivkar ◽  
Amol R. Gadbail ◽  
...  

Introduction. Gonial angle and antegonial region are important landmarks in mandible which is influenced by gender, age, and dental status. The objective of this study was to evaluate the gonial angle, antegonial angle, and antegonial depth and to investigate their relationship to gender, age group, and dental status. Materials and Methods. A total of 1060 panoramic radiographs were evaluated: the dentulous group, 854 subjects and the edentulous group, 206 subjects. The patients were grouped into six age groups of 10-years each. Gonial angle, antegonial angle, and antegonial depth were measured from panoramic radiographs. Results and Discussion. Corelation of age with gonial angle, antegonial angle and antegonial depth was not significant. Significant difference in mandibular angle was found between males and females. Males had significantly smaller antegonial angle and greater antegonial depth than females. Significant difference was found for gonial angle, antegonial angle, and antegonial depth between right and left sides of mandible. Conclusion. Gonial angle, antegonial angle, and antegonial depth can be implicated as a forensic tool for gender determination but not suitable for age determination.


Sign in / Sign up

Export Citation Format

Share Document