International Journal of Arrhythmia
Latest Publications


TOTAL DOCUMENTS

133
(FIVE YEARS 49)

H-INDEX

2
(FIVE YEARS 1)

Published By Korea Heart Rhythm Society

2466-1171, 2466-0981

2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Minki Hwang ◽  
Jae-Sun Uhm ◽  
Min Cheol Park ◽  
Eun Bo Shim ◽  
Chan Joo Lee ◽  
...  

Abstract Background Cardiac resynchronization therapy (CRT) is an effective treatment option for patients with heart failure (HF) and left ventricular (LV) dyssynchrony. However, the problem of some patients not responding to CRT remains unresolved. This study aimed to propose a novel in silico method for CRT simulation. Methods Three-dimensional heart geometry was constructed from computed tomography images. The finite element method was used to elucidate the electric wave propagation in the heart. The electric excitation and mechanical contraction were coupled with vascular hemodynamics by the lumped parameter model. The model parameters for three-dimensional (3D) heart and vascular mechanics were estimated by matching computed variables with measured physiological parameters. CRT effects were simulated in a patient with HF and left bundle branch block (LBBB). LV end-diastolic (LVEDV) and end-systolic volumes (LVESV), LV ejection fraction (LVEF), and CRT responsiveness measured from the in silico simulation model were compared with those from clinical observation. A CRT responder was defined as absolute increase in LVEF ≥ 5% or relative increase in LVEF ≥ 15%. Results A 68-year-old female with nonischemic HF and LBBB was retrospectively included. The in silico CRT simulation modeling revealed that changes in LVEDV, LVESV, and LVEF by CRT were from 174 to 173 mL, 116 to 104 mL, and 33 to 40%, respectively. Absolute and relative ΔLVEF were 7% and 18%, respectively, signifying a CRT responder. In clinical observation, echocardiography showed that changes in LVEDV, LVESV, and LVEF by CRT were from 162 to 119 mL, 114 to 69 mL, and 29 to 42%, respectively. Absolute and relative ΔLVESV were 13% and 31%, respectively, also signifying a CRT responder. CRT responsiveness from the in silico CRT simulation model was concordant with that in the clinical observation. Conclusion This in silico CRT simulation method is a feasible technique to screen for CRT non-responders in patients with HF and LBBB.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Raluca Sirbu Prisecaru ◽  
Cristina Leatu ◽  
Leila Riahi ◽  
Victor Costache

Abstract Purpose To compare the predictive accuracy of five different algorithms as verified by successful ablation site using 3D electroanatomical non-contact mapping in patients with symptomatic and asymptomatic but high ventricular burden RVOT tachycardias. Methods 28 Consecutive patients admitted for radiofrequency catheter ablation for symptomatic and asymptomatic, but high ventricular burden idiopathic VPC were recruited for this study. All patients had previous failed or intolerant to beta-blocker and/or at least one class IC anti-arrhythmic agents, and they had normal left ventricular ejection fraction. All patients had documented monomorphic VPC with left bundle branch block morphology and an inferior axis. Concordance of the arrhythmia origin based on ECG algorithm and 3D mapping system site were further evaluated. Of the five algorithms, two algorithms with easy‐applicability and having a memorable design (Dixit and Joshi) and three algorithms with more complex and detailed design (Ito, Zhang, Pytkowski) were selected for comparisons. Results Assessment of the diagnostic accuracy showed that each of the five algorithms had only moderate accuracy, and the greatest accuracy was observed in the algorithm proposed by Pytkowski algorithm when assessed by a general cardiologist and Dixit algorithm when evaluated by the electrophysiologist. However, when the algorithms were compared for their accuracy, specificity, sensitivity, no significant differences were found (p = 0.99). Conclusions The ECG based algorithms for precise localising RVOTA origin simplify the mapping process, reduce the procedural and fluoroscopic time, and improve clinical outcomes, resulting in greater clinical utility. All the five published 12-lead ECG algorithms for ROTVA differentiation were similar in terms of the diagnostic accuracy, specificity, sensitivity and LRs.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Oh-Seok Kwon ◽  
Inseok Hwang ◽  
Hui-Nam Pak

AbstractWith the aging society, the prevalence of atrial fibrillation (AF) continues to increase. Nevertheless, there are still limitations in antiarrhythmic drugs (AAD) or catheter interventions for AF. If it is possible to predict the outcome of AF management according to various AADs or ablation lesion sets through computational modeling, it will be of great clinical help. AF computational modeling has been utilized for in-silico arrhythmia research and enabled high-density entire chamber mapping, reproducible condition control, virtual intervention, not possible clinically or experimentally, in-depth mechanistic research. With the recent development of computer science and technology, more sophisticated and faster computational modeling has become available for clinical application. In particular, it can be applied to determine the extra-PV target of persistent AF catheter ablation or to select the AAD with the best effect. AF computational modeling combined with artificial intelligence is expected to contribute to precision medicine for more diverse uses in the future. Therefore, in this review, we will deal with the history, development, and various applications of computation modeling.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Jane Taleski ◽  
Svetlana Stankovik ◽  
Dejan Risteski ◽  
Filip Janusevski ◽  
Bekim Pocesta ◽  
...  

Abstract Background Minimally invasive and safe central venous access is imperative for lead insertion of cardiac implantable electronic devices (CIEDs). The purpose of this trial was to explore and compare the usability of the cephalic vein (CV) between both sexes. Methods and results This single-center prospective study included 102 consecutive patients in a period of six months. Pre-procedural contrast-enhanced venographic images of the upper arm were performed in all included patients. Our attention was focused on comparing several morpho-anatomical CV characteristics such as venous diameter, presence of valves and angle of entrance of the CV into the subclavian vein (SV). Study results concerning the CV morpho-anatomical differences were more favorable regarding the female patient group, with significant differences in CV diameter (p-0.030). There was also a difference in favor of the female group regarding the favorable CV angle of entrance into the SV, found in the 61.7% versus 54.4% in the male patient group. The comparison of usability of the CV and CVC technique was explored by comparing the number of leads inserted through the CV in both sexes. Two leads were implanted in 11.7% in the female group versus 5.8% in the male group, and 0 leads through the CV in 38.2% of the female patients versus 50% of male group. Conclusion Female patients have more favorable cephalic vein morpho-anatomical futures and better usability for lead placement than male patients.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Saira Rafaqat ◽  
Sana Rafaqat ◽  
Simon Rafaqat

Abstract Background The adipokines, secreted from adipose tissue or body fats, are also called adipocytokines which are cytokines, cell signaling proteins or cell–cell communication. However, AF is a common cardiac arrhythmia in which the heart beats so fast by abnormal beating and is a serious public health disease associated with increased heart failure, systemic thromboembolism, and death. Adipokines are cardiovascular disease (CVD) mediators or biomarkers that affect the heart as well as blood vessels, by increasing the cardiac contractility and action potential duration, which result in the extent of left ventricular and atrial remodeling. Main body Google Scholar, PubMed, and science direct were used to review the literature. Many keywords were used for searching the literature such as Adipokines, Leptin, Apelin, Adiponectin, Omentin-1, Chemerin, CTRP3, TNF-α, IL-6, IL-10, and AF. According to the literature, much more data are available for numerous adipokines, but this review article only has taken few major adipokines which played their major role in Atrial Fibrillation. The review article did not limit the time frame. Conclusion In conclusion, adipokines play a significant role in the development and progress of atrial fibrillation. Also, there are major adipokines such as adiponectin, apelin, C1q/TNF-Related Protein 3 (CTRP3), Chemerin, Omentin-1, interleukin-6, Leptin, TNF-α, resistin, and interleukin-10, which played their pathophysiological role in atrial fibrillation by causing cardiac hypertrophy, increasing the cardiac contractility and action potential duration, atrial fibrosis, electrical and structural remodeling of atrial tissue.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Euijae Lee ◽  
Hyoung-Seob Park ◽  
Seongwook Han ◽  
Gi-Byung Nam ◽  
Jong-Il Choi ◽  
...  

Abstract Background This study aims to investigate the current status of AF (atrial fibrillation) catheter ablation in Korea. Methods The patients who underwent AF catheter ablation from September 2017 to December 2019 were prospectively enrolled from 37 arrhythmia centers. Demographic data, procedural characteristics, the extent of catheter ablation, acute success of the ablation lesion set, rate and independent risk factor for recurrence of AF were analyzed. Results A total of 2402 AF patients [paroxysmal AF (PAF) 45.7%, persistent AF (PeAF) 43.1% and redo AF 11.2%] were included. Pulmonary vein isolation (PVI) was performed in 2378 patients (99%) and acute success rate was 97.9%. Additional non-PV ablation (NPVA) were performed in 1648 patients (68.6%). Post-procedural complication rate was 2.2%. One-year AF-free survival rate was 78.6% and the PeAF patients showed poorer survival rate than the ones with other types (PeAF 72.4%, PAF 84.2%, redo AF 80.0%). Additional NPVA did not influence the recurrence of AF in the PAF patients (PVI 17.0% vs. NPVA 14.6%, P value 0.302). However, it showed lower AF recurrence rate in the PeAF patients (PVI 34.9% vs. NPVA 24.4%, P value 0.001). Valvular heart disease, left atrial diameter, PeAF, PVI alone, need of NPVA for terminating AF, and failed ablation were independent predictors of AF recurrence. Conclusions Additional NPVA was associated better rhythm outcome in the patients with PeAF, not in the ones with PAF. The independent risk factors for AF recurrence in Korean population were similar to previous studies. Further research is needed to discover optimal AF ablation strategy.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Seil Oh ◽  
Yoon Ha Joo ◽  
Euijae Lee ◽  
So-Ryoung Lee ◽  
Myung-Jin Cha ◽  
...  

Abstract Background The major cause of recurrence after pulmonary vein (PV) isolation for atrial fibrillation (AF) is PV reconnection, and thicker wall could be associated with reconnection. Objectives This study aimed to evaluate the wall thickness of the PV antrum in reconnection sites using a three-dimensional (3D) wall thickness map. Methods A total of 91 patients who underwent a second ablation procedure due to AF recurrence were evaluated. The locations of the PV reconnection sites were confirmed in electroanatomical maps. A 3D atrial wall thickness (AWT) map was created using computed tomography scan data. The AWT values of the ablation lines of the index procedure were graded in each segment of the PV antrum: grade 1, 0.5 < AWT ≤ 1.0 mm; grade 2, 1.0 < AWT ≤ 1.5 mm; grade 3, 1.5 < AWT ≤ 2.0 mm; grade 4, 2.0 < AWT ≤ 2.5 mm; grade 5, AWT > 2.5 mm. Results A total of 281 PV reconnection sites among 1256 segments of the PV antrum in 79 patients were detected. The average AWT grades were 2.7 ± 1.0 and 2.2 ± 1.0 in the reconnected and non-reconnected segments, respectively (P < 0.01). Higher AWT grades were observed in the reconnected superior segments of the left superior PV, carina and inferior segments of the left inferior PV, superior and posterior segments of the right superior PV, and posterior and inferior segments of the right inferior PV. Conclusion The reconnected segments of the PV antrum showed thicker myocardium than the non-reconnected ones in patients with recurrent AF after catheter ablation. A wall thickness map for PV isolation could be considered for customized ablation in order to reduce PV reconnection.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Daehoon Kim ◽  
Pil-Sung Yang ◽  
Boyoung Joung

AbstractAtrial fibrillation (AF), the most common cardiac arrhythmia in the elderly population, has been associated with an impairment of cognitive function and an increased risk of dementia. Even though there does not appear to be solid evidence that any specific treatment prevents or delays AF-associated cognitive decline, evidence is accumulating regarding the possible treatment strategies for preventing dementia. Oral anticoagulation, especially non-vitamin K antagonist oral anticoagulants rather than warfarin use, has been suggested to be associated with reduced risk of dementia. Successfully maintaining sinus rhythm using catheter ablation might be also helpful in preventing subsequent dementia in patients with AF. In this review, we critically appraise the proposed treatment strategies for preventing AF-associated cognitive decline.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Pichmanil Khmao ◽  
Chun Hwang ◽  
Hui-Nam Pak

Abstract Background Ablation of idiopathic ventricular arrhythmias (VAs) in the cardiac crux region is one of the challenging procedures due to the complex anatomical structure where the four chambers of the heart are offset. Although this region is complex, the contiguous cardiac structures allow for the ablation of arrhythmias from adjacent sites. Case presentation We present different anatomical approaches in radiofrequency ablation and the ECG characteristics from a case series of VAs originated from the basal inferior ventricular septum, the corresponding endocardial aspect of the basal cardiac crux region. Conclusions Ablation of VAs originated from the basal cardiac crux region requires detailed mapping in the proximal coronary venous system and the adjacent structures including the RV, RA, and LV. In addition to the characteristic ECG of basal crux VAs, our three cases present an abrupt precordial transition in V2 with R wave amplitude greater than in V1 and V3.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Mohammad Paymard ◽  
Santabhanu Chakrabarti

Abstract Background The Advisor™ HD Grid Mapping Catheter (Abbott Technologies, Minneapolis, MN) has been recently introduced. Although the clinical use of HD Grid mapping catheter is well described in adults with no congenital heart disease, there is limited data on the feasibility of using the HD Grid multipolar catheter to create voltage and activation mapping in adults with congenital heart disease. The purpose of this study was to evaluate the safety and technical feasibility of using the Advisor™ HD Grid mapping catheter during the catheter ablation of atrial arrhythmias in adults with congenital heart disease. We included 6 consecutive adults with congenital heart disease suffering from atrial arrhythmias in our study. The HD Grid mapping catheter was used to perform voltage and activation mapping. Results Six patients with congenital heart diseases (d-TGA n = 1, Tricuspid atresia n = 1, atrioventricular defect repair n = 1, secundum atrial septal defect n = 1, double-inlet single-ventricle n = 1, Tetralogy of Fallot = 1); majority (84%) male, with the mean age was 35 ± 10 years included in our series. The mean ablation duration and the fluoroscopy time were 789 ± 433 and 502 ± 355 s, respectively. The mean radiation dose was 7.52 ± 9 milliGy/cm2. The HD Grid mapping catheter was used successfully for entire arrhythmia mapping in 5 out of 6 cases. During one procedure, HD Grid mapping catheter could not be used for the entire mapping due to suboptimal reach through baffle puncture. The acute success rate of ablation was 100% with no immediate complications. Conclusions The use of HD Grid mapping catheter is a safe and valuable adjunct to accurately create voltage and activation mapping in ACHD patients undergoing radiofrequency catheter ablation. However, a contact force-sensing ablation catheter should be considered in conjunction to supplement data acquisition in challenging anatomy and substrates.


Sign in / Sign up

Export Citation Format

Share Document