test conditions
Recently Published Documents


TOTAL DOCUMENTS

2105
(FIVE YEARS 408)

H-INDEX

53
(FIVE YEARS 5)

2021 ◽  
Vol 15 (1) ◽  
pp. 742-747
Author(s):  
John B. Bridgman ◽  
Andrew L. Newsom ◽  
David J. Chrisp ◽  
Abi E. Estelle ◽  
Mark Saunders

Aim: A pilot study was conducted with the aim of developing a system to protect the eyes, nose, and mouth from the aerosol generated from a high-speed dental handpiece during the COVID-19 pandemic. Background: The SARS-CoV-2 virus is known to be present in the saliva of an infected individual during the contagious viral shedding phase of the disease. The use of rotary dental instruments places oral health practitioners at risk of contracting COVID-19 from infected individuals. In particular, it is very difficult to protect the mucous membranes of the face against the extremely fine aerosol produced from a high-speed dental handpiece. Objectives: This study aimed to develop and test a novel PPE system for use during the COVID-19 pandemic. An air-fed spray-painting mask was used under a plastic hood to protect against the aerosol from a high-speed dental handpiece. This was found to be superior compared to hospital-issued N-95 masks and eye protection in our test model. Methods: Subjects donned various forms of PPE whilst using a high-speed dental handpiece in a confined cubicle. The efficacy of each form of PPE was evaluated by adding fluorescein to the water coolant supply line of a high-speed dental handpiece before checking for facial contamination with an ophthalmology slit lamp. Results: Under our test conditions, the N-95 mask did not prevent nasal and mouth contaminations, but the combination of an air-fed mask with a sealed hood prevented these contaminations. Although goggles worn tightly did prevent contamination, the air-fed mask system was far more comfortable and did not fog up. Discussion: Under the rigorous test conditions of our model, we found hospital-issued PPE ineffective. We also found the single strategy of using positive airflow into a face mask ineffective, even with extremely high levels of airflow. Complete protection was only achieved reliably by the combination of physically sealing off the face from the surrounding airspace and using the air-fed system to provide an external source of air to breathe. We effectively made the clinical equivalent of a dive bell helmet. The air-fed mask is supplied by a standard dental air compressor and is simple to install for someone familiar with the technical aspects of compressors. The compressor does not rely on a filter and proves effective with cheap and easily accessible disposable items. Conclusion: Under rigorous testing conditions, the developed air-fed mask system with a sealed hood on low flow performed better than hospital-issued PPE against high-speed dental aerosol protection. The developed system protects the operators from the air of the room contaminated with aerosol and brings in safe air from the outside for them to breathe.


2021 ◽  
Vol 12 (1) ◽  
pp. 284
Author(s):  
Tatiana Armijos-Moya ◽  
Pieter de Visser ◽  
Marc Ottelé ◽  
Andy van den Dobbelsteen ◽  
Philomena M. Bluyssen

Potted plants have been reported to uptake VOCs and help “cleaning” the air. This paper presents the results of a laboratory study in which two species of plants (peace lily and Boston fern) and three kinds of substrates (expanded clay, soil, and activated carbon) were tested and monitored on their capacity to deplete formaldehyde and CO2 in a glass chamber. Formaldehyde and CO2 were selected as indicators to evaluate the biofiltration efficacy of 28 different test conditions; relative humidity (RH) and temperature (T) were monitored during the experiments. To evaluate the efficacy of every test, the clean air delivery rate (CADR) was calculated. Overall, soil had the best performance in removing formaldehyde (~0.07–0.16 m3/h), while plants, in particular, were more effective in reducing CO2 concentrations (peace lily 0.01m3/h) (Boston fern 0.02–0.03 m3/h). On average, plants (~0.03 m3/h) were as effective as dry expanded clay (0.02–0.04 m3/h) in depleting formaldehyde from the chamber. Regarding air-cleaning performance, Boston ferns presented the best performance among the plant species, and the best performing substrate was the soil.


Author(s):  
Aniruddh Nayak ◽  
Stefan Gabriel ◽  
David Spenciner ◽  
Courtney Mason ◽  
Marc Jacofsky

Abstract Background: Multiple biomechanical shoulder simulators have been described in the literature, with a trend toward increasing complexity to better simulate clinical scenarios. Our objective was to develop an advanced, novel shoulder joint simulator and compare outcomes at two separate institutions, for a typical shoulder joint motion simulation. Methods: Identical shoulder simulators were developed & deployed at both institutions. Eight cadaveric upper extremities were tested by simulating actively controlled, arm elevation in the plane of the scapula for two sequential test conditions (intact and non-destructive simulated cuff-tear), each repeated for a total of five trials. Muscle forces and joint translations were recorded for both conditions. The intact condition was repeated following simulated cuff-tear to assess effect of testing order. Statistical analyses were aimed at assessing repeatability and reproducibility of results within specimens, between specimens, and between institutions. Results: The highest average forces were observed for the middle deltoid (233N or 32.5% body weight), followed by infraspinatus (99.0N), and posterior deltoid (93.7N) muscles. Differentiation between test conditions was unhindered by variability between repeated trials. Data from testing repeated over time, and between the two institutions were not significantly different. Conclusions: The novel shoulder simulator produced repeatable results with low trial-to-trial variation and outcomes were comparable between the two institutions. The results demonstrated a consistent response in muscle forces and humeral translation for the simulated rotator cuff tear condition. Such advanced shoulder simulators could thus be used for evaluating and optimizing surgical interventions and implant strategies.


Pharmaceutics ◽  
2021 ◽  
Vol 14 (1) ◽  
pp. 24
Author(s):  
Lauren Gallagher ◽  
Mary Joyce ◽  
Barry Murphy ◽  
Marc Mac Giolla Eain ◽  
Ronan MacLoughlin

There are variations in the values reported for aerosol drug delivery across in vitro experiments throughout the published literature, and often with the same devices or similar experimental setups. Factors contributing to this variability include, but are not limited to device type, equipment settings, drug type and quantification methods. This study assessed the impact of head model choice on aerosol drug delivery using six different adults and three different paediatric head models in combination with a facemask, mouthpiece, and high-flow nasal cannula. Under controlled test conditions, the quantity of drug collected varied depending on the choice of head model. Head models vary depending on a combination of structural design differences, facial features (size and structure), internal volume measurements and airway geometries and these variations result in the differences in aerosol delivery. Of the widely available head models used in this study, only three were seen to closely predict in vivo aerosol delivery performance in adults compared with published scintigraphy data. Further, this testing identified the limited utility of some head models under certain test conditions, for example, the range reported across head models was aerosol drug delivery of 2.62 ± 2.86% to 37.79 ± 1.55% when used with a facemask. For the first time, this study highlights the impact of head model choice on reported aerosol drug delivery within a laboratory setting and contributes to explaining the differences in values reported within the literature.


Author(s):  
Shingo Shimazaki ◽  
Qinzhong Shi

AbstractGround acoustic tests using stationary sound pressure level spectrum have been conducted to verify the spacecraft survivability against acoustic environment acting on a spacecraft during launch, which is a non-stationary and random dynamic load. In general, a stationary spectrum used in ground acoustic test is traditionally determined by a method called maximax spectrum, which is the enveloped spectrum of time varying non-stationary short-time Fourier transform. However, the maximax spectrum is more or less an excessively conservative test condition because this spectrum focuses on processing of a time-varying acoustic signal itself to extract maximum value, rather than on how the vibro-acoustic response of an excited structure is. In this paper, a new method is proposed to specify a stationary spectrum equivalent to a structural vibro-acoustic response under a non-stationary and random acoustic environment based on extreme response spectrum and fatigue damage spectrum. This proposed method was applied to flight telemetry of both liquid- and solid-propellant launch vehicles developed by JAXA, to show its effect to mitigate the acoustic test conditions compared to the maximax spectrum while maintaining the equivalence of the structural vibro-acoustic response. Furthermore, the maximum predicted environment, which is the statistical upper percentiles of the flight telemetry of eight liquid-propellant launch vehicles, by the proposed method achieved a mitigation of about 2.5 and 6.8 dB in the extreme stress and cumulative fatigue, respectively, compared to the that which is calculated by the conventional maximax spectrum.


2021 ◽  
Vol 15 ◽  
Author(s):  
Johanna Wind ◽  
Fabian Horst ◽  
Nikolas Rizzi ◽  
Alexander John ◽  
Tamara Kurti ◽  
...  

To date, most neurophysiological dance research has been conducted exclusively with female participants in observational studies (i.e., participants observe or imagine a dance choreography). In this regard, the sex-specific acute neurophysiological effect of physically executed dance can be considered a widely unexplored field of research. This study examines the acute impact of a modern jazz dance choreography on brain activity and functional connectivity using electroencephalography (EEG). In a within-subject design, 11 female and 11 male participants were examined under four test conditions: physically dancing the choreography with and without music and imagining the choreography with and without music. Prior to the EEG measurements, the participants acquired the choreography over 3 weeks with one session per week. Subsequently, the participants conducted all four test conditions in a randomized order on a single day, with the EEG measurements taken before and after each condition. Differences between the male and female participants were established in brain activity and functional connectivity analyses under the condition of imagined dance without music. No statistical differences between sexes were found in the other three conditions (physically executed dance with and without music as well as imagined dance with music). Physically dancing and music seem to have sex-independent effects on the human brain. However, thinking of dance without music seems to be rather sex-specific. The results point to a promising approach to decipher sex-specific differences in the use of dance or music. This approach could further be used to achieve a more group-specific or even more individualized and situationally adapted use of dance interventions, e.g., in the context of sports, physical education, or therapy. The extent to which the identified differences are due to culturally specific attitudes in the sex-specific contact with dance and music needs to be clarified in future research.


Polymers ◽  
2021 ◽  
Vol 13 (24) ◽  
pp. 4295
Author(s):  
Hai Wang ◽  
Annan Sun ◽  
Xiaowen Qi ◽  
Yu Dong ◽  
Bingli Fan

The tribological properties of polytetrafluoroethylene (PTFE)/AP (poly(para-phenyleneterephthalamide) (PPTA) pulp) composites under different test conditions (load: 2N, 10N; frequency: 1 Hz, 4 Hz; amplitude: 2 mm, 8 mm) were holistically evaluated. PTFE/AP composites with different AP mass ratios of 3%, 6%, and 12% as a skeleton support material were prepared. The coefficient of friction (COF) and wear rate were determined on a ball-on-disk tribometer. Furthermore, the morphology, element composition, and chemical structure of the transfer membrane were analyzed accordingly. The relationships between load, frequency, amplitude, and tribological properties were further investigated. According to the wear mechanism, AP enables effective improvement in the stiffness and wear resistance, which is also conducive to the formation of transfer films.


Author(s):  
Dong shan Li ◽  
Ning Kong ◽  
Ruishan Li ◽  
Boyang Zhang ◽  
Yongshun Zhang ◽  
...  

Abstract Judicious selection of additives having chemical and physical compatibility with the DLC films may help improving the triboligical properties and durability life of DLC-oil composite lubrication systems. In this study, Cu nanoparticles were added to PAO6 base oil to compose a solid-liquid composite lubrication system with W-DLC film. The effects of nanoparticle concentration, test temperature and applied load on tribological performance were systematically studied by a ball-on-disk friction test system. The tribological results illustrated that Cu nanoparticles could lower the coefficient of friction (COF) and dramatically reduce the wear rates of W-DLC films. The optimal tribological behavior was achieved for the 0.1 wt.% concentration under 30 ℃ and the applied load of 100 N. The test temperature and applied load were vital influencing factors of the solid–liquid lubrication system. The bearing effect and soft colloidal abrasive film of spherical Cu nanoparticle contributed to the excellent tribological performance of the composite lubrication system under mild test conditions, meanwhile, the local delamination of W-DLC film and oxidation were the main causes of the friction failure under harsh test conditions. With test temperature and applied loads increase the degree of graphitization of the W-DLC film increased. In conclusion, there are several pivotal factors affecting the tribological performance of solid–liquid lubrication systems, including the number of nanoparticles between rubbing contact area, graphitization of the worn W-DLC films, tribofilms on the worn ball specimens and oxidation formed in friction test, and the dominant factor is determined by the testing condition.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Xin Wang ◽  
Qian Zhang ◽  
Fangjie Liu ◽  
Yifan Jin ◽  
Xin Li

AbstractReactivity controlled compression ignition (RCCI) engines have a high thermal efficiency as well as low emissions of soot and nitrogen oxides (NOx). However, there is a conflict between combustion stability and harmful emissions at high engine load. Therefore, this work presented a novel approach for regulating n-butanol/methyl oleate dual fuel RCCI at high engine load in attaining lower pollutant emissions while maintaining stable combustion and avoiding excessive in-cylinder pressure. The tests were conducted on a single cylinder engine under rated speed and 90% full load. In this study, n-butanol was selected as a low-reactivity fuel for port injection, and n-butanol/methyl oleate blended fuel was used for in-cylinder direct injection. Combustion and emission characteristics of the engine were first investigated with varied ratios of n-butanol port injection (PFI) and direct injection (DI). Results showed that as the ratio of n-butanol PFI and DI rose, the peak cylinder pressure and heat release rate increased, while NOx and soot emissions reduced, and carbon monoxide (CO) and hydrocarbon (HC) emissions increased under most test conditions. When RNBPI = 40% and RNBDI = 20%, the soot and NOx emissions of the engine were near the lowest values of all test conditions, yet the peak in-cylinder pressure and fuel consumption could not increase significantly. Therefore, the possibility of optimizing the combustion process and lowering emissions by adjusting the pilot injection strategy was investigated utilizing these fuel injection ratios. The results revealed that with an appropriate pilot injection ratio and interval, the peak in-cylinder pressure and NOx emission were definitely reduced, while soot, CO, and HC emissions did not significantly increase.


Nanomaterials ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 3261
Author(s):  
Wenhao Wang ◽  
Lu Zhang ◽  
Yanli Kang ◽  
Feng Yu

(1) Background: Toluene gas is widely used in indoor decoration and industrial production, and it not only pollutes the environment but also poses serious health risks. (2) Methods: In this work, TiO2−CoFe2O4−Ag quaternary composite gas-sensing material was prepared using a hydrothermal method to detect toluene. (3) Results: The recombination of electron–hole pairs was suppressed, and the light absorption range was expanded after constructing a heterojunction and doping with Ag, according to ultraviolet–visible (UV–vis) diffuse reflectance spectra and photoluminescence spectroscopy. Moreover, in the detection range of toluene gas (3 ppm–50 ppm), the response value of TiO2−CoFe2O4−Ag increased from 2 to 15, which was much higher than that of TiO2−Ag (1.7) and CoFe2O4−Ag (1.7). In addition, the working temperature was reduced from 360 °C to 263 °C. Furthermore, its response/recovery time was 40 s/51 s, its limit of detection was as low as 10 ppb, and its response value to toluene gas was 3–7 times greater than that of other interfering gases under the same test conditions. In addition, the response value to 5 ppm toluene was increased from 3 to 5.5 with the UV wavelength of 395 nm–405 nm. (4) Conclusions: This is primarily due to charge flow caused by heterojunction construction, as well as metal sensitization and chemical sensitization of novel metal doping. This work is a good starting point for improving gas-sensing capabilities for the detection of toluene gas.


Sign in / Sign up

Export Citation Format

Share Document