Scanning electron microscope calibration with simultaneous electron probe diameter determination

1994 ◽  
Vol 37 (6) ◽  
pp. 710-713
Author(s):  
Yu. A. Novikov ◽  
A. V. Rakov ◽  
I. Yu. Stekolin ◽  
I. B. Strizhkov
Author(s):  
S. Takashima ◽  
H. Hashimoto ◽  
S. Kimoto

The resolution of a conventional transmission electron microscope (TEM) deteriorates as the specimen thickness increases, because chromatic aberration of the objective lens is caused by the energy loss of electrons). In the case of a scanning electron microscope (SEM), chromatic aberration does not exist as the restrictive factor for the resolution of the transmitted electron image, for the SEM has no imageforming lens. It is not sure, however, that the equal resolution to the probe diameter can be obtained in the case of a thick specimen. To study the relation between the specimen thickness and the resolution of the trans-mitted electron image obtained by the SEM, the following experiment was carried out.


Author(s):  
David Joy ◽  
James Pawley

The scanning electron microscope (SEM) builds up an image by sampling contiguous sub-volumes near the surface of the specimen. A fine electron beam selectively excites each sub-volume and then the intensity of some resulting signal is measured. The spatial resolution of images made using such a process is limited by at least three factors. Two of these determine the size of the interaction volume: the size of the electron probe and the extent to which detectable signal is excited from locations remote from the beam impact point. A third limitation emerges from the fact that the probing beam is composed of a finite number of discrete particles and therefore that the accuracy with which any detectable signal can be measured is limited by Poisson statistics applied to this number (or to the number of events actually detected if this is smaller).


1997 ◽  
Vol 3 (S2) ◽  
pp. 1243-1244 ◽  
Author(s):  
Raynald Gauvin ◽  
Steve Yue

The observation of microstructural features smaller than 300 nm is generally performed using Transmission Electron Microscopy (TEM) because conventional Scanning Electron Microscopes (SEM) do not have the resolution to image such small phases. Since the early 1990’s, a new generation of microscopes is now available on the market. These are the Field Emission Gun Scanning Electron Microscope with a virtual secondary electron detector. The field emission gun gives a higher brightness than those obtained using conventional electron filaments allowing enough electrons to be collected to operate the microscope with incident electron energy, E0, below 5 keV with probe diameter smaller than 5 nm. At 1 keV, the electron range is 60 nm in aluminum and 10 nm in iron (computed using the CASINO program). Since the electron beam diameter is smaller than 5 nm at 1 keV, the resolution of these microscopes becomes closer to that of TEM.


2013 ◽  
Vol 20 (1) ◽  
pp. 78-89 ◽  
Author(s):  
Eric Lifshin ◽  
Yudhishthir P. Kandel ◽  
Richard L. Moore

AbstractA method is presented for determining the point spread function (PSF) of an electron beam in a scanning electron microscope for the examination of near planar samples. Once measured, PSFs can be used with two or more low-resolution images of a selected area to create a high-resolution reconstructed image of that area. As an example, a 4× improvement in resolution for images is demonstrated for a fine gold particle sample. Since thermionic source instruments have high beam currents associated with large probe sizes, use of this approach implies that high-resolution images can be produced rapidly if the probe diameter is less of a limiting factor. Additionally, very accurate determination of the PSFs can lead to a better understanding of instrument performance as exemplified by very accurate measurement of the beam shape and therefore the degree of astigmatism.


1993 ◽  
Vol 36 (12) ◽  
pp. 1348-1350
Author(s):  
Yu. A. Novikov ◽  
A. V. Rakov ◽  
I. Yu. Stekolin ◽  
I. B. Strizhkov