scholarly journals Error estimation on extracorporeal trajectory determination from body scans

Author(s):  
F. Riva ◽  
U. Buck ◽  
K. Buße ◽  
R. Hermsen ◽  
E. J. A. T. Mattijssen ◽  
...  

AbstractThis study explores the magnitude of two sources of error that are introduced when extracorporeal bullet trajectories are based on post-mortem computed tomography (PMCT) and/or surface scanning of a body. The first source of error is caused by an altered gravitational pull on soft tissue, which is introduced when a body is scanned in another position than it had when hit. The second source of error is introduced when scanned images are translated into a virtual representation of the victim’s body. To study the combined magnitude of these errors, virtual shooting trajectories with known vertical angles through five “victims” (live test persons) were simulated. The positions of the simulated wounds on the bodies were marked, with the victims in upright positions. Next, the victims were scanned in supine position, using 3D surface scanning, similar to a body’s position when scanned during a PMCT. Seven experts, used to working with 3D data, were asked to determine the bullet trajectories based on the virtual representations of the bodies. The errors between the known and determined trajectories were analysed and discussed. The results of this study give a feel for the magnitude of the introduced errors and can be used to reconstruct actual shooting incidents using PMCT data.

2020 ◽  
Vol 23 ◽  
pp. 200423
Author(s):  
Chihiro Tanaka ◽  
Hajime Utsuno ◽  
Yohsuke Makino ◽  
Saki Minegishi ◽  
Jun Ota ◽  
...  

2020 ◽  
Vol 6 (2) ◽  
pp. 20190076
Author(s):  
Paul Lockwood ◽  
James Elliott ◽  
Andrew Nelson ◽  
Samantha Harris

CT scanning techniques used in head and facial bones examination in the clinical environment can also be transferable to the imaging of post-mortem cases as a novel non-destructive and non-invasive investigation in forensic cases. We describe a study of the head and facial bones of a 2700-year-old Egyptian mummy. Cross-sectional investigation can lead to discovering unknown information of skeletal and soft tissue structures and anatomy to contribute to the knowledge of preserved mummified remains and the practice of palaeoradiology.


2020 ◽  
Vol 21 ◽  
pp. 200370
Author(s):  
Nicole Loper ◽  
Kate O'Connor ◽  
David Milne ◽  
Kilak Kesha ◽  
Simon Stables ◽  
...  

2013 ◽  
Vol 61 (S 01) ◽  
Author(s):  
B Vogel ◽  
H Gulbins ◽  
H Reichenspurner ◽  
A Heinemann ◽  
H Vogel

2013 ◽  
Vol 61 (S 01) ◽  
Author(s):  
B Vogel ◽  
H Gulbins ◽  
H Reichenspurner ◽  
A Heinemann ◽  
H Vogel

Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.


Author(s):  
Sabina Strano-Rossi ◽  
Serena Mestria ◽  
Giorgio Bolino ◽  
Matteo Polacco ◽  
Simone Grassi ◽  
...  

AbstractScopolamine is an alkaloid which acts as competitive antagonists to acetylcholine at central and peripheral muscarinic receptors. We report the case of a 41-year-old male convict with a 27-year history of cannabis abuse who suddenly died in the bed of his cell after having smoked buscopan® tablets. Since both abuse of substances and recent physical assaults had been reported, we opted for a comprehensive approach (post-mortem computed tomography CT (PMCT), full forensic autopsy, and toxicology testing) to determine which was the cause of the death. Virtopsy found significant cerebral edema and lungs edema that were confirmed at the autopsy and at the histopathological examination. Scopolamine was detected in peripheral blood at the toxic concentration of 14 ng/mL in blood and at 263 ng/mL in urine, and scopolamine butyl bromide at 17 ng/mL in blood and 90 ng/mL in urine. Quetiapine, mirtazapine, lorazepam, diazepam, and metabolites and valproate were also detected (at therapeutic concentrations). Inmates, especially when they have a history of drug abuse, are at risk to use any substance they can find for recreational purposes. In prisons, active surveillance on the management and assumption of prescribed drugs could avoid fatal acute intoxication.


Sign in / Sign up

Export Citation Format

Share Document