scholarly journals Controlled, prospective, randomized, clinical split-mouth evaluation of partial ceramic crowns luted with a new, universal adhesive system/resin cement: results after 18 months

2016 ◽  
Vol 20 (9) ◽  
pp. 2481-2492 ◽  
Author(s):  
Vanessa Vogl ◽  
Karl-Anton Hiller ◽  
Wolfgang Buchalla ◽  
Marianne Federlin ◽  
Gottfried Schmalz
2017 ◽  
Vol 11 (02) ◽  
pp. 253-257 ◽  
Author(s):  
Sthelen Nayara Cenci ◽  
Igor Alessandro Gontarsky ◽  
Marcella Goetz Moro ◽  
Lidia Olga Bach Pinheiro ◽  
Adriana Postiglione Bührer Samra

ABSTRACTThe loss of upper front dental elements causes functional and psychosocial problems to the affected individuals. In this case report, the treatment planning considered hard and soft tissue loss for a complex fixed partial denture (FPD) rehabilitation. The six-element, all-ceramic FPD was manufactured using a computer-aided design/computer-aided manufacturing system with zirconia framework, veneered with leucite-reinforced ceramic. Ceramic artificial gum was also produced to guarantee tooth-facial proportions as well as lip support, promoting both esthetics and phonetics. The material's mechanical properties allowed for the coupling of the esthetic and mechanical requirements, proving an alternative to the well-established metal-ceramic technology, optimizing biomimetic. One of the endodontic-treated abutment teeth required a radicular retainer with cast metal post, but because of the opacity of zirconia, the esthetics of the prosthesis was not compromised. The low silica content of high resistance ceramics such as zirconia hampers the adhesive cementation, with numerous studies advocating for different cementation protocols, with no clear scientific consensus so far. In the present case, the internal surface of the FPD was initially blasted with aluminum oxide, followed by the application of a universal adhesive system containing 10-methacryloyloxydecyl dihydrogen phosphate. Finally, cementation to the dental structure was conducted with dual-cure self-adhesive resin cement.


2008 ◽  
Vol 33 (5) ◽  
pp. 516-525 ◽  
Author(s):  
F. Schenke ◽  
K-A. Hiller ◽  
G. Schmalz ◽  
M. Federlin

Clinical Relevance Resin coating improves the marginal seal of partial ceramic crowns to dentin compared to conventional luting, especially at the dentin/composite interface. However, the self-adhesive material RelyX Unicem shows significantly better marginal integrity than the other materials tested.


2019 ◽  
Vol 44 (2) ◽  
pp. 200-209 ◽  
Author(s):  
F Murillo-Gómez ◽  
RB Wanderley ◽  
MF De Goes

SUMMARY The aim of this study was to determine whether using a silane-containing universal adhesive as a silane primer in glass-ceramic/resin cement systems affects biaxial flexural strength (BFS) and bonded interface integrity after loading. Glass-ceramic (IPS e.max CAD, Ivoclar/Vivadent, Schaan, Liechtenstein) disc-shaped specimens (6.5±0.1mm in diameter, 0.5±0.1mm thick) were etched with 5% hydrofluoric acid (HF) for 20 seconds and divided into four groups of 30 specimens, to be treated as follows: 1) One bottle silane primer (RCP); 2) Separate application of silane and adhesive (RCP+SB); 3) Silane-containing universal adhesive (SBU); 4) No treatment (C). After silanization, all specimens were resin cement– coated and polymerized for 40 seconds. Each specimen layer was measured, as well as each assembly's thickness, using a digital caliper and scanning electron microscope (SEM). Specimens were stored for 24 hours and submitted to a BFS test (1.27 mm/min). BFS values were calculated using the bilayer disc-specimen solution. Bonded interfaces were analyzed on fractured fragments using SEM. One-way ANOVA and Tukey tests (α=0.05) were applied, as well as the Weibull analysis. Factor “silane treatment” was statistically significant (p<0.0001). RCP+SB (372.2±29.4 MPa) and RCP (364.2±29.5 MPa) produced significantly higher BFS than did the C (320.7±36.3 MPa) or SBU (338.0±27.1 MPa) groups. No differences were found in the Weibull modulus (m: RCP: 10.1-17.3; RCP+SB: 10.1-17.0; SBU: 12.3-22.4; C: 7.4-12.9). Bonded interface analysis exhibited ceramic-cement separation (SBU, C) and voids within the resin cement layer (all groups). Neither the ceramic/cement system's BFS nor its bonded interface stability were improved by SBU after loading.


2014 ◽  
Vol 22 (4) ◽  
pp. 287-293 ◽  
Author(s):  
Luana Menezes de MENDONÇA ◽  
Luiz Fernando PEGORARO ◽  
Marcos Daniel Septímio LANZA ◽  
Thiago Amadei PEGORARO ◽  
Ricardo Marins de CARVALHO

2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Zohreh Moradi ◽  
Farnoosh Akbari ◽  
Sara Valizadeh

Aim. This study aimed to assess shear bond strength (SBS) of resin cement to zirconia ceramic with different surface treatments by using Single Bond Universal. Methods. In this in vitro study, 50 zirconia discs (2 × 6 mm) were divided into 5 groups of (I) sandblasting with silica-coated alumina (CoJet)  + silane + Single Bond 2, (II) sandblasting with CoJet + Single Bond Universal, (III) sandblasting with alumina + Single Bond Universal, (IV) sandblasting with alumina + Z-Prime Plus, and (V) Single Bond Universal with no surface treatment. Resin cement was applied in plastic tubes (3 × 5 mm2), and after 10,000 thermal cycles, the SBS was measured by a universal testing machine. The mode of failure was determined under a stereomicroscope at × 40 magnification. Data were analyzed using one-way ANOVA. Results. The maximum (6.56 ± 4.29 MPa) and minimum (1.94 ± 1.96 MPa) SBS values were noted in groups III and I, respectively. Group III had the highest frequency of mixed failure (60%). Group V had the maximum frequency of adhesive failure (100%). Conclusion. Single Bond Universal + sandblasting with alumina or silica-coated alumina particles is an acceptable method to provide a strong SBS between resin cement and zirconia.


2015 ◽  
Vol 16 (7) ◽  
pp. 547-553 ◽  
Author(s):  
Roberta Tarkany Basting ◽  
Cecília Pedroso Turssi ◽  
Flavia Lucisano Botelho do Amaral ◽  
Fabiana Mantovani Gomes França ◽  
Rafaela Crystyan Vaneli ◽  
...  

ABSTRACT Aim The aim of this study was to evaluate the effect of chlorhexidine and ethanol application on the push-out bond strength and bond durability of fiber posts cemented with an etch-and-rinse adhesive system/resin cement to intraradicular dentin. Materials and methods Fifty-four bovine roots were shaped for the cementation of a fiberglass post and received the application of 37% phosphoric acid. They were then randomly divided into three groups, according to the type of dentin treatment (n = 18) performed: no treatment (control group), 100% ethanol, or 2% chlorhexidine. Next, the adhesive system (Adper Scotch Bond Multipurpose Plus, 3M ESPE) was applied to the dentin, according to the manufacturer's instructions. Glass fiber posts were cemented with dual resin cement (Rely X ARC, 3M ESPE). After 48 hours, the specimens were serially sectioned for push-out test analysis, providing two slices from each root third (cervical, medium and apical), one of which was tested immediately and the other stored in distilled water for 180 days. The data were analyzed with three-way analysis of variance (ANOVA) for repeated measures and Tukey's test at a 5% significance level. Results Intraradicular treatment with chlorhexidine yielded the highest bond strength means, followed by ethanol treatment. The control group presented the lowest bond strength means. Water storage exerted no effect on bond strength values. Conclusion Both chlorhexidine and ethanol improved push-out bond strength to intraradicular dentin, with the former providing the best results, regardless of the storage time. Clinical significance The application of 2% chlorhexidine or 100% ethanol may be an important step that can be taken to enhance bond strength of fiber posts to intraradicular dentin, when dual resin cements are used. How to cite this article França FMG, Vaneli RC, de Melo Conti C, Basting RT, do Amaral FLB, Turssi CP. Effect of Chlorhexidine and Ethanol Application on Long-term Pushout Bond Strength of Fiber Posts to Dentin. J Contemp Dent Pract 2015;16(7):547-553.


Polymers ◽  
2020 ◽  
Vol 12 (2) ◽  
pp. 461 ◽  
Author(s):  
Joana Vasconcelos e Cruz ◽  
Mário Polido ◽  
José Brito ◽  
Luisa L. Gonçalves

Due to their polymerization characteristics, hyper-branched dendrimers have lately shown to be promising candidates for use in dental materials. In this study, a new dental adhesive system was prepared, using a dendrimer derived from 2-isocyanatoethyl methacrylate (G-IEMA), and its adhesive properties were investigated. The exposed dentin was treated with four universal adhesives (UAs): SBU (Scotchbond Universal™), FUT (Futurabond M+™), AE1 (experimental adhesive with Bis-GMA) and AE2 (experimental adhesive with G-IEMA), using Etch & Rinse (ER) or Self Etch (SE) protocols. Composite build-ups were prepared and stored for 24 h at 37 °C in distilled water. Composite/dentin beams were prepared with cross-sectional areas of 1 ± 0.3 mm2 and µTBS (Micro-tensile bond strength) test was performed at 0.5 mm/min. Failures modes were evaluated by stereomicroscopy, and bonding interfaces were observed by scanning electron microscopy (SEM). Statistical analysis of µTBS data was performed using General Linear (GLM) and Linear Mixed Models (LMM). The effect of adhesive type on µTBS was significant (p = 0.010), with AE1 presenting significantly higher µTBS than SBU (p = 0.019). No other differences between adhesives were observed. ER showed significantly better results than SE (p = 0.019), and no significant interactions between the adhesives and protocols were determined. Results obtained so far pinpoint the emergence of a new paradigm in the dental materials field, as G-IEMA can be used successfully as an alternative to Bis-GMA.


Sign in / Sign up

Export Citation Format

Share Document