X-ray diffraction and continuous small-angle scattering of turkey tendons with the improved area detector at Frascati

Author(s):  
Jitendra Shantilal Shah ◽  
Andrea La Monaca ◽  
Adriana Bigi ◽  
Norberto Roveri
1967 ◽  
Vol 11 ◽  
pp. 332-338 ◽  
Author(s):  
Donald M. Koffman

AbstractAn X-ray small-angle scattering instrument is described which is used for recording X-ray diffraction patterns or small-angle X-ray scattering curves in an angular region very close to the direct beam. The measurement of X-ray intensity is accomplished with standard geiger or scintillation counter techniques. The instrument is designed for use with a spot-focus or vertical-line X-ray source, In essence, it is a multiple-reflection double-crystal diffractometer, based on a concept developed by Bonse and Hart, employing two grooved perfect germanium crystals arranged in the parallel position. Multiple diffraction from these crystals produces a monochromated X-ray beam which can be several millimeters wide while still exhibiting extremely high angular resolution. As a result, effective sample volumes can be employed with maximum volume-to-thickness ratios. The principal features of the instrument are discussed with emphasis on the advantages of this device over those employing complex slit systems and film-re cording techniques, Data are presented to illustrate the operation, intensity, and resolution of the unit.


2015 ◽  
Vol 48 (6) ◽  
pp. 1660-1664 ◽  
Author(s):  
Yuya Shinohara ◽  
Yoshiyuki Amemiya

This study shows that forward scattering at the origin of reciprocal space contributes to the scattering intensity profiles of ultra-small-angle scattering. The forward scattering corresponds to a Fourier transform of the X-ray coherent volume on a sample. This contribution is usually ignored in the study of small-angle scattering, while it is fully considered in the fields of X-ray imaging, such as coherent X-ray diffraction imaging and X-ray ptychography. This effect is explicitly illustrated in the context of small-angle scattering, and the effect of a finite spatial coherence length on small-angle scattering is discussed.


1988 ◽  
Vol 97 ◽  
pp. 227-230 ◽  
Author(s):  
P. Lamparter ◽  
S. Steeb ◽  
D.M. Kroeger ◽  
S. Spooner

1977 ◽  
Vol 10 (1) ◽  
pp. 37-44 ◽  
Author(s):  
C. Cabos ◽  
P. Delord ◽  
J. Rouviere

The structure of micellar solutions is determined from X-ray small-angle scattering measurements on an absolute scale. The most probable structure is chosen by comparison with spherical cylindrical and lamellar models. This method is applied to two-component micelles and it is possible to follow the variation of micellar dimensions when the concentration of each component is varying.


Sign in / Sign up

Export Citation Format