Optimization of a CZT photon counting detector for contaminant detection

2021 ◽  
Vol 16 (11) ◽  
pp. P11015
Author(s):  
J. Nguyen ◽  
P.-A. Rodesch ◽  
D. Richtsmeier ◽  
K. Iniewski ◽  
M. Bazalova-Carter

Abstract In the food industry, X-ray inspection systems are utilized to ensure packaged food is free from physical contaminants to maintain a high level of food safety for consumers. However, one of the challenges in the food industry is detecting small, low-density contaminants from packaged food. Cadmium zinc telluride (CZT) photon counting detectors (PCDs) can potentially alleviate this problem given its multi-energy bin capabilities, high spatial resolution and ability to eliminate electronic noise, which is superior to the conventional energy integrating detector (EID). However, the image quality from a CZT PCD can be further improved by applying an optimized energy bin weighting scheme that maximizes energy bin images that provide the largest image contrast and lowest image noise. Therefore, in this work, five contaminant materials embedded in an acrylic phantom were imaged using a CZT PCD while the phantom was in constant motion to mimic food products moving on a conveyor belt. Energy bin optimization was performed by applying an image-based weighting scheme and these results showed contrast-to-noise ratio (CNR) improvements ranging between 1.02–1.91 relative to an equivalent EID acquisition.

Sensors ◽  
2020 ◽  
Vol 20 (2) ◽  
pp. 383 ◽  
Author(s):  
Yingrui Li ◽  
Gangqiang Zha ◽  
Yu Guo ◽  
Shouzhi Xi ◽  
Lingyan Xu ◽  
...  

Counting rate is an important factor for CdZnTe photon counting detectors as high-flux devices. Until recently, there has been a lack of knowledge on the relationship between X-ray photocurrent response and the photon counting performance of CdZnTe detectors. In this paper, the performance of linear array 1 × 16-pixel CdZnTe photon counting detectors operated under different applied biases is investigated. The relation between experimental critical flux and applied bias show an approximate quadratic dependence, which agrees well the theoretical prediction. The underlying relationship among X-ray photocurrents, carrier transport properties, and photon counting performance was obtained by analyzing X-ray current–voltage and time current curves. The typical X-ray photocurrent curve can be divided into three regions, which may be explained by the photoconductive gain mechanism and electric field distortion characteristics. To keep CdZnTe photon counting detectors working in a “non-polarized state”, the applied bias should be set on the left side of the “valley region” (high bias direction) in the X-ray I-V curves. This provides an effective measurement for determining the proper working bias of CdZnTe detectors and screening photon counting detector crystals.


2006 ◽  
Author(s):  
Anton S. Tremsin ◽  
Oswald H. W. Siegmund ◽  
John V. Vallerga ◽  
Jeff S. Hull

2021 ◽  
pp. 1-13
Author(s):  
Muhammad U. Ghani ◽  
Farid H. Omoumi ◽  
Xizeng Wu ◽  
Laurie L. Fajardo ◽  
Bin Zheng ◽  
...  

PURPOSE: To compare imaging performance of a cadmium telluride (CdTe) based photon counting detector (PCD) with a CMOS based energy integrating detector (EID) for potential phase sensitive imaging of breast cancer. METHODS: A high energy inline phase sensitive imaging prototype consisting of a microfocus X-ray source with geometric magnification of 2 was employed. The pixel pitch of the PCD was 55μm, while 50μm for EID. The spatial resolution was quantitatively and qualitatively assessed through modulation transfer function (MTF) and bar pattern images. The edge enhancement visibility was assessed by measuring edge enhancement index (EEI) using the acrylic edge acquired images. A contrast detail (CD) phantom was utilized to compare detectability of simulated tumors, while an American College of Radiology (ACR) accredited phantom for mammography was used to compare detection of simulated calcification clusters. A custom-built phantom was employed to compare detection of fibrous structures. The PCD images were acquired at equal, and 30% less mean glandular dose (MGD) levels as of EID images. Observer studies along with contrast to noise ratio (CNR) and signal to noise ratio (SNR) analyses were performed for comparison of two detection systems. RESULTS: MTF curves and bar pattern images revealed an improvement of about 40% in the cutoff resolution with the PCD. The excellent spatial resolution offered by PCD system complemented superior detection of the diffraction fringes at boundaries of the acrylic edge and resulted in an EEI value of 3.64 as compared to 1.44 produced with EID image. At MGD levels (standard dose), observer studies along with CNR and SNR analyses revealed a substantial improvement of PCD acquired images in detection of simulated tumors, calcification clusters, and fibrous structures. At 30% less MGD, PCD images preserved image quality to yield equivalent (slightly better) detection as compared to the standard dose EID images. CONCLUSION: CdTe-based PCDs are technically feasible to image breast abnormalities (low/high contrast structures) at low radiation dose levels using the high energy inline phase sensitive imaging technique.


2011 ◽  
Vol 59 (5) ◽  
pp. 3114-3119 ◽  
Author(s):  
Yu-Na Choi ◽  
Seung-Wan Lee ◽  
Hyo-Min Cho ◽  
Hyun-Ju Ryu ◽  
Young-Jin Lee ◽  
...  

2016 ◽  
Author(s):  
Liang Li ◽  
Ruizhe Li ◽  
Siyuan Zhang ◽  
Zhiqiang Chen

Sign in / Sign up

Export Citation Format

Share Document