Co-simulation study on airflow field and dynamic electric field of high voltage SF6 circuit breaker

Author(s):  
Hao Zhang ◽  
Zhijun Wang ◽  
Yongqi Yao ◽  
Yapei Liu ◽  
Yingqian Du ◽  
...  
2013 ◽  
Vol 448-453 ◽  
pp. 2045-2048
Author(s):  
Yan Zhong Ju ◽  
Xin Lei Wu

Choosing LW15-550Y porcelain high voltage SF6 circuit breaker as the research subject, we designed the lead laminated rubber bearing (LRB) seismic isolation device for LW15-550Y circuit breaker. We finally gets the results that the LRB isolation system increases the flexibility of the breaker structure and improves the seismic performance of the high voltage circuit breaker structure.