It analyses the composition and principle of high-sensitive wide-band magnetic-feedback inductive magnetic sensor to fulfil the demand of high-sensitive wide-band magnetic sensor in geological exploration. It studies main factors to the performance of wide-band magnetic sensor, such as turns of coils, core material features, and amplifier noise, specifies section-wise coil winding, the type and dimension of core material, and designs low-noise high-impedance LF chopping amplifier channel and composite amplifier with HF amplifier channel. The noise of magnetic sensor at 1 Hz is better than 10-4nT/Hz1/2, at 100Hz-1kHz band the noise floor is close to SQUID which can reach 10-6nT/Hz1/2. The magnetic sensor works at wide frequency band (0.0001Hz-10kHz) and ultra-low noise, which can meet the requirements of both AMT and CSAMT.