Voltage Distribution Analysis of 500-kV DC Transmission-Line Voltage Divider Under Impulse Voltages: Results and Discussions

2006 ◽  
Vol 21 (2) ◽  
pp. 584-590 ◽  
Author(s):  
S. Gu ◽  
S. Han ◽  
J. He ◽  
S. Chen ◽  
G. Xu
2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
S. Hemalatha ◽  
P. Valsalal

Power system network can undergo outages during which there may be a partial or total blackout in the system. In that condition, transmission of power through the optimal path is an important problem in the process of reconfiguration of power system components. For a given set of generation, load pair, there could be many possible paths to transmit the power. The optimal path needs to consider the shortest path (minimum losses), capacity of the transmission line, voltage stability, priority of loads, and power balance between the generation and demand. In this paper, the Bellman Ford Algorithm (BFA) is applied to find out the optimal path and also the several alternative paths by considering all the constraints. In order to demonstrate the capability of BFA, it has been applied to a practical 230 kV network. This restorative path search guidance tool is quite efficient in finding the optimal and also the alternate paths for transmitting the power from a generating station to demand.


With rapid industrial and commercial growth and flourishing population, power demand is increasing rapidly. Modern methods of UHV transmission lines are important to transmit bulk amount of power more efficiently in comparison to earlier methods of transmission. 1200 KV UHV transmission line is India future and therefore forthcoming project to tackle this situation. However as line to line voltage level increases, complexity of the transmission line increases. But, with higher level of line to line voltage, complexity of transmission line increases. ROW is one of the major concerns with transmission lines. Many parameters need to take care in designing; one of them is a magnetic field distribution at surroundings of transmission line. India has initiated to expand its UHV range to 1200kv. Paper suggest magnetic field of three configurations of the 1200KV line. Horizontal and vertical configuration test lines have been installed. Analysis has been done by two methods finite element method and (Method of images) analytical method. FEM is used to solve partial differential equations. Results from both methods have been compared. 3D electric field analysis of configuration also performed. Plotted results are compared with ICNIRP standards and safety limits defined. Adverse effects of excess magnetic field is also discussed. Biological effects of electromagnetic field on people, animals and plants are also discussed. Thus paper aimed at magnetic field calculation and verification with respect to standard. It also helps to utilize less right of way. The subject is under broad development due to its advantages over lower voltage levels and holds significance in future as well.


IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 185804-185815
Author(s):  
Kaijian Wu ◽  
Zhao Yuan ◽  
Jingjing Ye ◽  
Junxiang Liu ◽  
Wenxiong Mo ◽  
...  

Energies ◽  
2018 ◽  
Vol 11 (3) ◽  
pp. 593 ◽  
Author(s):  
Pulin Cao ◽  
Hongchun Shu ◽  
Bo Yang ◽  
Na An ◽  
Dalin Qiu ◽  
...  

1998 ◽  
Vol 47 (5) ◽  
pp. 1265-1270 ◽  
Author(s):  
D.W.P. Thomas ◽  
R.E. Batty ◽  
C. Christopoulos ◽  
A. Wang