Ductile Crack Initiation Criterion with Mismatched Weld Joints Under Dynamic Loading Conditions

2018 ◽  
Vol 18 (3) ◽  
pp. 2252-2257 ◽  
Author(s):  
Gyubaek An ◽  
Se-Min Jeong ◽  
Jeongung Park
2021 ◽  
Author(s):  
Chengyun Miao ◽  
Haishun Du ◽  
Xinyu Zhang ◽  
Hareesh Tippur

Abstract Cellulose nanopaper (CNP) made of cellulose nanofibrils (CNF) has gained extensive attention in recent years for its lightweight and superior mechanical properties alongside sustainable and green attributes. The mechanical characterization studies on CNP at the moment have generally been limited to tension tests. In fact, thus far there has not been any report on crack initiation and growth behavior, especially under dynamic loading conditions. In this work, crack initiation and growth in self-assembled CNP, made from filtration of CNF suspension, are studied using a full-field optical method. Dynamic crack initiation and growth behaviors and time-resolved fracture parameters are quantified using Digital Image Correlation (DIC) technique. The challenge associated with dynamic loading of a thin strip of CNP has been overcome by an acrylic holder with a wide pre-cut slot bridged by edge-cracked CNP. The ultrahigh-speed digital photography is implemented to map in-plane deformations during pre- and post-crack initiation regimes including dynamic crack growth. Under stress wave loading conditions, macroscale crack growth occurs at surprisingly high-speed (600-700 m/s) in this microscopically fibrous material. The measured displacement fields from dynamic loading conditions are analyzed to extract stress intensity factors (SIF) and energy release rate (G) histories. The results show that the SIF at crack initiation is in the range of 6-7 MPa(m)1/2, far superior to many engineering plastics. Furthermore, the measured values increase during crack propagation under both low- and high-strain rates, demonstrating superior fracture resistance of CNP valuable for many structural applications.


Author(s):  
Jason P. Halloran ◽  
Anthony J. Petrella ◽  
Paul J. Rullkoetter

The success of current total knee replacement (TKR) devices is contingent on the kinematics and contact mechanics during in vivo activity. Indicators of potential clinical performance of total joint replacement devices include contact stress and area due to articulations, and tibio-femoral and patello-femoral kinematics. An effective way of evaluating these parameters during the design phase or before clinical use is via computationally efficient computer models. Previous finite element (FE) knee models have generally been used to determine contact stresses and/or areas during static or quasi-static loading conditions. The majority of knee models intended to predict relative kinematics have not been able to determine contact mechanics simultaneously. Recently, however, explicit dynamic finite element methods have been used to develop dynamic models of TKR able to efficiently determine joint and contact mechanics during dynamic loading conditions [1,2]. The objective of this research was to develop and validate an explicit FE model of a TKR which includes tibio-femoral and patello-femoral articulations and surrounding soft tissues. The six degree-of-freedom kinematics, kinetics and polyethylene contact mechanics during dynamic loading conditions were then predicted during gait simulation.


Sign in / Sign up

Export Citation Format

Share Document