Meta-Heuristic BPSO Based Voltage Profile Enhancement in Radial Distribution System Through Network Reconfiguration

Author(s):  
Mounika Kannan ◽  
Kirithikaa Sampath ◽  
Srividhya Pattabiraman ◽  
K Narayanan ◽  
Tomonobu Senjyu

Abstract Abnormal Voltages in electrical distribution system is a threat to power system security and may cause equipment damages. Reconfiguration aids in the proper distribution of load and thus improving the voltage profile. The multi objective framework including node voltage deviation as primary objective and power loss and reliability as secondary objectives is formulated. The novel meta heuristic method based on binary particle swarm optimization (BPSO) is employed to find the optimal radial distribution network configuration for an assortment of objective function. The effect of inertia weight, position and population of swarm is deeply investigated. The proposed method has been verified on IEEE 33 and 69 bus radial distribution systems and found to be effective in minimizing node voltage deviation. The impact of the reconfigured system on voltage deviation, power loss and reliability has been studied extensively. BPSO calculations are found to be simple and has good Convergence characteristics in comparison with other meta heuristic techniques.

Energies ◽  
2019 ◽  
Vol 12 (8) ◽  
pp. 1500 ◽  
Author(s):  
Hadi Suyono ◽  
Mir Toufikur Rahman ◽  
Hazlie Mokhlis ◽  
Mohamadariff Othman ◽  
Hazlee Azil Illias ◽  
...  

Technological advancement, environmental concerns, and social factors have made plug-in electric vehicles (PEVs) popular and attractive vehicles. Such a trend has caused major impacts to electrical distribution systems in terms of efficiency, stability, and reliability. Moreover, excessive power loss, severe voltage deviation, transformer overload, and system blackouts will happen if PEV charging activities are not coordinated well. This paper presents an optimal charging coordination method for a random arrival of PEVs in a residential distribution network with minimum power loss and voltage deviation. The method also incorporates capacitor switching and on-load tap changer adjustment for further improvement of the voltage profile. The meta-heuristic methods, binary particle swarm optimization (BPSO) and binary grey wolf optimization (BGWO), are employed in this paper. The proposed method considers a time-of-use (ToU) electricity tariff such that PEV users will get more benefits. The random PEV arrival is considered based on the driving pattern of four different regions. To demonstrate the effectiveness of the proposed method, comprehensive analysis is conducted using a modified of IEEE 31 bus system with three different PEV penetrations. The results indicate a promising outcome in terms of cost and the distribution system stress minimization.


Author(s):  
S. Bhongade ◽  
Sachin Arya

The work presented in this paper is carried out with the objective of identifying the optimal location and size (Kvar ratings) of shunt capacitors to be placed in radial distribution system, to have overall economy considering the saving due to energy loss minimization. To achieve this objective, a two stage methodology is adopted in this paper. In the first stage, the base case load flow of uncompensated distribution system is carried out. On the basis of base case load flow solution, Nominal voltage magnitudes and Loss Sensitivity Factors are calculated and the weak buses are selected for capacitor placement.In the second stage, Particle Swarm Optimization (PSO) algorithm is used to identify the size of the capacitors to be placed at the selected buses for minimizing the power loss. The developed algorithm is tested for 10-bus, 34-bus and 85-bus Radial Distribution Systems. The results show that there has been an enhancement in voltage profile and reduction in power loss thus resulting in much annual saving.


2013 ◽  
Vol 768 ◽  
pp. 371-377 ◽  
Author(s):  
E. Rekha ◽  
D. Sattianadan ◽  
M. Sudhakaran

Distributed generators (DG) are much beneficial in reducing the losses effectively compared to other methods of loss reduction. It is expected to become more important in future generation. This paper deals with the multi DGs placement in radial distribution system to reduce the system power loss and improve the voltage profile by using the optimization technique of particle swarm optimization (PSO). The PSO provides a population-based search procedure in which individuals called particles change their positions with time. Initially, the algorithm randomly generates the particle positions representing the size and location of DG. The proposed PSO algorithm is used to determine optimal sizes and locations of multi-DGs. The objective function is the combination of real, reactive power loss and voltage profile with consideration of weights and impact indices with and without DG. Test results indicate that PSO method can obtain better results on loss reduction and voltage profile improvement than the simple heuristic search method on the IEEE33-bus and IEEE 90-bus radial distribution systems.


Author(s):  
Charles R. Sarimuthu ◽  
Vigna K. Ramachandaramurthy ◽  
H. Mokhlis ◽  
K.R. Agileswari

The use of distributed generation (DG) within distribution systems has increased for the last two decades due to worldwide increase in demand for electricity and governmental policy change from “conventional” energy to “green” energy. High levels of penetration of DG have many significant benefits but also come with many drawbacks such as voltage drop and power losses. This study presents the impact of DG at different locations in a distribution feeder in terms of the feeder voltage profile. A radial distribution system is simulated using PSCAD/EMTDC simulation software while changing the size and location of DG in the system. The obtained results are used for better understanding on the impact of DG on voltage profile in radial distribution feeder.


2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Varaprasad Janamala

AbstractA new meta-heuristic Pathfinder Algorithm (PFA) is adopted in this paper for optimal allocation and simultaneous integration of a solar photovoltaic system among multi-laterals, called interline-photovoltaic (I-PV) system. At first, the performance of PFA is evaluated by solving the optimal allocation of distribution generation problem in IEEE 33- and 69-bus systems for loss minimization. The obtained results show that the performance of proposed PFA is superior to PSO, TLBO, CSA, and GOA and other approaches cited in literature. The comparison of different performance measures of 50 independent trail runs predominantly shows the effectiveness of PFA and its efficiency for global optima. Subsequently, PFA is implemented for determining the optimal I-PV configuration considering the resilience without compromising the various operational and radiality constraints. Different case studies are simulated and the impact of the I-PV system is analyzed in terms of voltage profile and voltage stability. The proposed optimal I-PV configuration resulted in loss reduction of 77.87% and 98.33% in IEEE 33- and 69-bus systems, respectively. Further, the reduced average voltage deviation index and increased voltage stability index result in an improved voltage profile and enhanced voltage stability margin in radial distribution systems and its suitability for practical applications.


2021 ◽  
Vol 11 (2) ◽  
pp. 774 ◽  
Author(s):  
Ahmed S. Abbas ◽  
Ragab A. El-Sehiemy ◽  
Adel Abou El-Ela ◽  
Eman Salah Ali ◽  
Karar Mahmoud ◽  
...  

In recent years, with the widespread use of non-linear loads power electronic devices associated with the penetration of various renewable energy sources, the distribution system is highly affected by harmonic distortion caused by these sources. Moreover, the inverter-based distributed generation units (DGs) (e.g., photovoltaic (PV) and wind turbine) that are integrated into the distribution systems, are considered as significant harmonic sources of severe harmful effects on the system power quality. To solve these issues, this paper proposes a harmonic mitigation method for improving the power quality problems in distribution systems. Specifically, the proposed optimal planning of the single tuned harmonic filters (STFs) in the presence of inverter-based DGs is developed by the recent Water Cycle Algorithm (WCA). The objectives of this planning problem aim to minimize the total harmonic distortion (THD), power loss, filter investment cost, and improvement of voltage profile considering different constraints to meet the IEEE 519 standard. Further, the impact of the inverter-based DGs on the system harmonics is studied. Two cases are considered to find the effect of the DGs harmonic spectrum on the system distortion and filter planning. The proposed method is tested on the IEEE 69-bus distribution system. The effectiveness of the proposed planning model is demonstrated where significant reductions in the harmonic distortion are accomplished.


Author(s):  
Diego Issicaba ◽  
Jorge Coelho

This paper introduces a modified edition of classical Cespedes' load flow method to radial distribution system analysis. In the developed approach, a distribution network is modeled in different complex reference systems and reduced to a set of connected equivalent subnetworks, each without resistance, while graph topology and node voltage solution are preserved. Active power losses are then not dissipated in the modeled subnetworks and active power flows can be obtained as a consequence of radiality. Thus, the proposed method preprocesses a series of variable transformations concomitant to an iterative algorithm using a forward-backward sweep to arrive at the load flow solution. The proposed approach has been tested using literature and actual distribution networks, and efficiency improvements are verified in comparison to Cespedes' load flow method.


Author(s):  
Su Mon Myint ◽  
Soe Win Naing

Nowadays, the electricity demand is increasing day by day and hence it is very important not only to extract electrical energy from all possible new power resources but also to reduce power losses to an acceptable minimum level in the existing distribution networks where a large amount of power dissipation occurred. In Myanmar, a lot of power is remarkably dissipated in distribution system.  Among methods in reducing power losses, network reconfiguration method is employed for loss minimization and exhaustive technique is also applied to achieve the minimal loss switching scheme. Network reconfiguration in distribution systems is performed by opening sectionalizing switches and closing tie switches of the network for loss reduction and voltage profile improvement. The distribution network for existing and reconfiguration conditions are modelled and simulated by Electrical Transient Analyzer Program (ETAP) 7.5 version software. The inputs are given based on the real time data collected from 33/11kV substations under Yangon Electricity Supply Board (YESB). The proposed method is tested on 110-Bus, overhead AC radial distribution network of Dagon Seikkan Township since it is long-length, overloaded lines and high level of power dissipation is occurred in this system. According to simulation results of load flow analysis, voltage profile enhancement and power loss reduction for proposed system are revealed in this paper.