Protocols for Mechanical Cleaning of the Post Space on the Bond Strength Between Root Dentin and Cementation System

2021 ◽  
Author(s):  
CM Alencar ◽  
JRE Verbicário dos Santos ◽  
FFA Jassé ◽  
GO dos Santos ◽  
WG Escalante-Otárola ◽  
...  

SUMMARY Objective: To evaluate the effects of mechanical versus chemical cleaning protocols for cleaning the root dentin surface before cementation of fiberglass posts for their effect on the bond strength, failure mode, and dentinal penetration of the cementing agent using an etch-and-rinse adhesive system on dentin prepared to receive a fiberglass post. Methods: Forty roots of bovine teeth were endodontically treated and prepared for fiber post cementation. The specimens were randomized into 4 groups of 10: Control group (CO) - irrigation with 2.5% NaOCl; DW group- irrigation with distilled water; RB group - rotating brush for cleaning root canals, and CUI group - continuous ultrasonic irrigation. The fiberglass posts were cemented, and the specimens were immersed in distilled water for 6 months. A push-out test was performed on the cervical, middle, and apical thirds of the samples. Dentinal penetration of the cementing agent and the fracture pattern were evaluated by laser confocal microscopy. Statistical analysis was performed using analysis of variance (ANOVA) and post hoc Tukey tests (α=0.05). Results: The RB and CUI groups showed significantly higher bond strength values when compared to the Control and DW groups (p<0.05). In addition, in the control and DW groups, the apical third presented lower bond strength values when compared to middle and cervical thirds. Conclusion: While DW showed the highest incidence of adhesive type failure, CUI resulted in the highest dentinal penetration of the cementing agent (p<0.05). RB and CUI resulted in the highest bond strength between cementation system and root dentin. In addition, CUI favored greater dentinal penetration of fiberglass post cementing agent.

2015 ◽  
Vol 16 (7) ◽  
pp. 547-553 ◽  
Author(s):  
Roberta Tarkany Basting ◽  
Cecília Pedroso Turssi ◽  
Flavia Lucisano Botelho do Amaral ◽  
Fabiana Mantovani Gomes França ◽  
Rafaela Crystyan Vaneli ◽  
...  

ABSTRACT Aim The aim of this study was to evaluate the effect of chlorhexidine and ethanol application on the push-out bond strength and bond durability of fiber posts cemented with an etch-and-rinse adhesive system/resin cement to intraradicular dentin. Materials and methods Fifty-four bovine roots were shaped for the cementation of a fiberglass post and received the application of 37% phosphoric acid. They were then randomly divided into three groups, according to the type of dentin treatment (n = 18) performed: no treatment (control group), 100% ethanol, or 2% chlorhexidine. Next, the adhesive system (Adper Scotch Bond Multipurpose Plus, 3M ESPE) was applied to the dentin, according to the manufacturer's instructions. Glass fiber posts were cemented with dual resin cement (Rely X ARC, 3M ESPE). After 48 hours, the specimens were serially sectioned for push-out test analysis, providing two slices from each root third (cervical, medium and apical), one of which was tested immediately and the other stored in distilled water for 180 days. The data were analyzed with three-way analysis of variance (ANOVA) for repeated measures and Tukey's test at a 5% significance level. Results Intraradicular treatment with chlorhexidine yielded the highest bond strength means, followed by ethanol treatment. The control group presented the lowest bond strength means. Water storage exerted no effect on bond strength values. Conclusion Both chlorhexidine and ethanol improved push-out bond strength to intraradicular dentin, with the former providing the best results, regardless of the storage time. Clinical significance The application of 2% chlorhexidine or 100% ethanol may be an important step that can be taken to enhance bond strength of fiber posts to intraradicular dentin, when dual resin cements are used. How to cite this article França FMG, Vaneli RC, de Melo Conti C, Basting RT, do Amaral FLB, Turssi CP. Effect of Chlorhexidine and Ethanol Application on Long-term Pushout Bond Strength of Fiber Posts to Dentin. J Contemp Dent Pract 2015;16(7):547-553.


2017 ◽  
Vol 20 (4) ◽  
pp. 55
Author(s):  
Rafael Avellar de Carvalho Nunes ◽  
Flávia Lucisano Botelho do Amaral ◽  
Fabiana Mantovani Gomes França ◽  
Cecilia Pedroso Turssi ◽  
Roberta Tarkany Basting

<p class="Corpo"><strong>Objective</strong>: the aim of the present study was to evaluate the influence of adding different concentrations of chitosan to an experimental two-step etch-and-rinse adhesive system on the bond strength and failure mode to dentin. <strong>Material</strong> <strong>and</strong> <strong>Methods</strong>: thirty-two flat dentin surfaces were obtained from extracted human third molars and divided into four groups  (n=8) for application of the adhesive systems: AD - conventional two-step adhesive system (Adper Single Bond 2); EXP – experimental two-step etch-and-rinse adhesive system; Chi0.2% - EXP with addition of 0.2% Chitosan; Chi0.5% - EXP with addition of 0.5% Chitosan. Resin composite build-ups were made and the composite/dentin specimens were sectioned to obtain rectangular beams with a bond area of approximately 1mm<sup>2</sup>. After 24 hours, the sticks were submitted to microtensile bond strength tests in a universal test machine. The fracture pattern was evaluated under a stereoscopic loupe at 40X magnification. <strong>Results</strong>: one-way analysis of variance showed that the type of adhesive system had no significant effect on the bond strength values (p = 0.142), showing the mean bond strength values (standard deviation), in MPa, for the groups as follows: AD=20.1 (5.4); EXP=16.6 (2.3); Chi0.2%=16.1 (2.8); Chi0.5%=16.9 (2.3). In all the groups there was predominance of cohesive fractures in dentin, representing 68 to 82% of the failure modes. <strong>Conclusion</strong>: the addition of 0.2 or 0.5% of chitosan had no influence on the bond strength and failure mode of an experimental two-step etch-and-rinse adhesive system to dentin.</p><p class="Corpo"><strong>Keywords</strong></p><p class="Corpo">Chitosan; Dental Adhesives; Failure Mode; Microtensile Bond Strength.</p>


2021 ◽  
Vol 15 (2) ◽  
pp. 82-86
Author(s):  
Mahmoud Bahari ◽  
Siavash Savadi Oskoee ◽  
Mohammad Esmaeel Ebrahimi Chaharom ◽  
Nasim Molayi

Background. Contamination of dentin surface is one of the common problems in restorative dentistry. The aim was to investigate the effects of different surface contaminators on the dentin shear bond strength (SBS) of universal adhesive system (UAS) applied in etch-and-rinse (ER) and self-etch (SE) strategies. Methods. One hundred forty-four maxillary anterior sound human teeth were divided into six groups based on the types of surface contaminators: no surface contaminator (control) and experimental groups contaminated with blood, saliva, aluminium chloride (ALC), ferric sulphate (FS), and caries disclosing agent (CDA). Then, each group was further subdivided into two, based on the application strategy of UAS (ER and SE). After applying the adhesive according to the manufacturer’s instructions, and bonding cylindrical composite samples, the SBS was measured. The data were analysed using two-way ANOVA, Tukey’s HSD test and t test (P<0.05). Results. The SBS in all contaminated groups, except for CDA, was significantly lower in both ER and SE strategies compared to control group (P<0.05). A comparison between the application strategies revealed that ER and SE were only significantly different in the FS contaminated group (P<0.05). Conclusion. All tested contaminators, except CDA, significantly decreased SBS of UAS in both ER and SE strategies.


2012 ◽  
Vol 06 (01) ◽  
pp. 056-062 ◽  
Author(s):  
Adriano Fonseca Lima ◽  
Vinícius Brito da Silva ◽  
Giulliana Panfiglio Soares ◽  
Giselle Maria Marchi ◽  
Flávio Henrique Baggio Aguiar ◽  
...  

ABSTRACTObjectives: The aim of this study was to evaluate the (1) bond strength of a etch-and-rinse and self-etching adhesive systems to cavosurface enamel, (2) influence of the previous acid etching with phosphoric acid 35% to the self-etching adhesive application on bond strength values, and (3) analysis of the cavosurface enamel morphology submitted to different types of conditioning, with the use of a scanning electronic microscope (SEM).Methods: Twenty four human third molars were sectioned on mesio-distal direction, resulting in two slices. The specimens were ground flat with 600-grit aluminum oxide papers, and were randomly divided into three groups: Group 1 (etch-and-rinse adhesive system (control group)), Group 2 (selfetching adhesive), and Group 3 (self-etching adhesive with previous 35% phosphoric acid-etching for 15 s). Four cylinders (0.75 mm of diameter, 1 mm height) were confectioned prior to the microshear test. Four samples for each group were prepared according the cavosurface enamel treatment and were analyzed in an SEM.Results: Group 3 had the highest values on bond strength to cavosurface enamel compared to the other two groups, which presented statistically similar values. The performance of acid etching before the application of the self-etching adhesive results in an etching pattern that is different than the other groups, favoring the adhesion to the cavosurface enamel.Conclusions: Acid etching increases the bond strength values of the self-etching adhesive to cavosurface enamel, promoting a conditioning pattern that favors the adhesion to this substrate. (Eur J Dent 2012;6:56-62)


2016 ◽  
Vol 27 (4) ◽  
pp. 442-445 ◽  
Author(s):  
Beatriz Carlos Correa ◽  
Rodrigo Galo ◽  
Camila Scatena ◽  
Maria Cristina Borsatto ◽  
Aloísio Oro Spazzin ◽  
...  

Abstract This study evaluated the effect of matrix metalloproteinase (MMP) inhibitors - 2% (CHX) and sodium fluoride (NaF) (5000 ppm) - on microtensile bond strength (μTBS) of composite resin to Er:YAG laser-irradiated dentin after chemical degradation of the bond interface. The occlusal surface of forty sound human molars was removed exposing the dentin surface (n=10), which was polished, irradiated with Er:YAG laser, acid etched and dried. Twenty specimens were rewetted with 2% CHX (control group) and 20 were rewetted with NaF (5000 ppm). The adhesive system was applied and a 4-mm-high plateau of light-cured composite resin was built up. Resin-dentin sticks were obtained with a rectangular cross-sectional area (0.8-1 mm2) and were either stored in water at 37 ?#61616;C for 24 h or submitted to chemical degradation. For chemical degradation, they were immersed in 10% NaOCl aqueous solution for 5 h and rinsed in water for 1 h. The sticks were submitted to microtensile test in a mechanical testing machine at 0.5 mm/min until failure. Fracture pattern was analyzed using SEM. μTBS values were calculated in MPa and submitted to analysis of variance ANOVA (α=0.05). The variance analysis showed that the 'MMP inhibitor' and 'degradation' factors (p=0.214 and p=0.093, respectively) and interaction between the factors were not statistically significant (p=0.143). Mixed failure predominated in all groups. In conclusion, the 2% CHX and NaF 5000 ppm presented similar μTBS of composite resin to laser-irradiated dentin before and after chemical degradation


2019 ◽  
Vol 13 (02) ◽  
pp. 199-205
Author(s):  
Gabriela Oliveira Borgo ◽  
Waldemir Francisco Vieira-Junior ◽  
Jéssica Dias Theobaldo ◽  
Flávio Henrique Baggio Aguiar ◽  
Débora Alves Nunes Leite Lima

Abstract Objective The main purpose of this study was to evaluate the effect of dentin pretreatment with 8% arginine on the immediate and 6-month bond strength (BS) of adhesive systems and surface morphology of dentin. Materials and Methods Dentin bovine specimens (5 × 5 mm) were allocated into following pretreatments: without pretreatment (conventional technique, C) or exposure to arginine solution (A) for 5 minutes prior to tooth restoration. The adhesive procedure was performed using (n = 12): 3-step etch-and-rinse adhesive (Scotchbond Multipurpose—SBMP [C+SBMP and A+SBMP]); 2-step etch-and-rinse adhesive (Single Bond 2 - SB [C+SB and A+SB]); or 2-step self-etch adhesive (Clearfil SE Bond - CSEB [C+CSEB and A+CSEB]). After 24 hours, the composite resin restorations were evaluated immediately and after 6 months of water storage using a microshear test and fracture pattern. The dentin surface exposed to A was assessed by scanning electron microscopy (SEM). The immediate BS data were submitted to a two-way analysis of variance and Tukey's test, and the long-term BS results were analyzed using Kruskal–Wallis and Dunn tests (α = 0.05). Results There was a significant decrease in immediate and 6-month BS for the A+SB and A+CSEB groups, which differed statistically from the C group. The fracture pattern was predominantly adhesive for SB and CSEB adhesive for C and A. The SEM images presented a different conditioning pattern of the dentin exposed to A. Conclusion The dentin pretreatment with arginine interfered negatively in the immediate and long-term BS of the simplified adhesive system. However, the SBMP adhesive was not affected by arginine pretreatment presenting the most satisfactory results.


2013 ◽  
Vol 24 (6) ◽  
pp. 605-609 ◽  
Author(s):  
Tamara Kerber Tedesco ◽  
Eugenio Jose Garcia ◽  
Fabio Zovico Maxnuck Soares ◽  
Rachel de Oliveira Rocha ◽  
Rosa Helena Miranda Grande

This in vitro study evaluated the influence of two devices for application of shear load in microshear tests on bond strength and fracture pattern of primary enamel and dentin. Eighty primary molars were selected and flat enamel (40 teeth sectioned mesio-distally) and dentin (40 teeth sectioned transversally) surfaces were obtained. Both surfaces were polished to standardize the smear layer. Two-step etch-and-rinse adhesive systems (Adper Single Bond and XP Bond) were used. Polyethylene tubes was placed over the bonded surfaces and filled with composite resin. The microshear testing was performed after storage in water (24 h/37 °C) using two devices for application of microshear loads: a notched rod (Bisco Shear Bond Tester) or a knife edge (Kratos Industrial Equipment). Failure modes were evaluated using a stereomicroscope. Bond strength data were subjected to ANOVA and chi-square test to compare the failure mode distributions (α=0.05). No significant differences were observed between the groups for dentin and enamel bond strength or fracture patterns (p>0.05). The predominant failure mode was adhesive/mixed. In conclusion, the devices for application of shear loads did not influence the bond strength values, regardless of adhesive system and substrate.


2012 ◽  
Vol 13 (4) ◽  
pp. 464-471 ◽  
Author(s):  
Sergio Brossi Botta ◽  
Adriana Bona Matos ◽  
Bruna Uglik Garbui ◽  
Andre Figueiredo Reis

ABSTRACT Aim The aim of this study was to analyze and compare the influence of short-term NaOCl-storage and long-term water storage on the microtensile bond strength (μTBS) of etch-andrinse adhesive system to human dentin. Materials and methods Thirty-six third human molars were randomly divided into 6 groups (n = 6) according to the aging protocol: G1 (water, 24 hours); G2 (water, 6 months); G3 (water, 12 months); G4 (10% sodium hypochlorite – NaOCl, 1 hour); G5 (10% NaOCl, 3 hours) and G6 (10% NaOCl, 5 hours). A two-step etch-and-rinse adhesive (Adper Single Bond 2) was applied according to the manufacturers¡¦ instructions. A composite (Filtek Z250) was applied in four horizontal increments and was individually cured. Specimens were cut following the microtensile test technique, submitted to the different aging protocols, and tested in tension. The fracture pattern was observed in a stereomicroscope (40× magnification) and in a scanning electron microscope. The μTBS data were analyzed by ANOVA and Tukey's test (α = 0.05). Results The effect of storage in 10% NaOCl for 1 or 3 hours was not significantly different from that of aging in distilled water (DW) for 6 or 12 months (p > 0.05). Beams immersed in DW for 24 hours and in 10% NaOCl for 5 hours showed the highest and lowest ìTBS values respectively. Conclusion The aging protocols negatively influenced dentin bond strength. Aging specimens in 10% NaOCl for 1 or 3 hours can be an alternative method for long-term water storage (6 or 12 months) bond strength studies. Clinical significance This aging protocol allows a quick achievement of longitudinal bond strength data, so that results are available to the professionals in this area while the materials are yet present at the dental market. How to cite this article Garbui BU, Botta SB, Reis AF, Matos AB. Comparison of Chemical Aging and Water Immersion Time on Durability of Resin-Dentin Interface produced by an Etchand- Rinse Adhesive. J Contemp Dent Pract 2012;13(4):464-471.


2008 ◽  
Vol 19 (4) ◽  
pp. 341-347 ◽  
Author(s):  
Jaciara Miranda Gomes-Silva ◽  
Carolina Paes Torres ◽  
Marta Maria Martins Giamatei Contente ◽  
Maria Angélica Hueb de Menezes Oliveira ◽  
Regina Guenka Palma-Dibb ◽  
...  

This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fisher's test (α=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (±4.29); II-8.57 (±3.19); III-7.97 (±2.16); IV-12.56 (±3.11); V-11.45 (±3.77); and VI-7.47 (±1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.


2018 ◽  
Vol 66 (4) ◽  
pp. 339-344
Author(s):  
Mayara Farah Dallin SERAFIM ◽  
Adriana Mara Araújo LEAL ◽  
José BAUER ◽  
Isabella Azevedo GOMES ◽  
Karina Gama Kato CARNEIRO

ABSTRACT Objective: evaluate bond strength of a universal adhesive, associated to an extra hydrophobic sealing layer, and compare after three and six months immersed in distilled water. Methods: After ethical approval of the CEP / HUUFMA, 12 human third molars (n = 6) were extracted, which were divided into two groups: SB - control group - selfetching; and SBHidrof - selfetching group associated to the hydrophobic layer (Adhesive layer, 3m ESPE). After incremental restoration with composite resin (Opalis, FGM), the teeth were sliced to obtain specimens (1mm2) and then submitted to the universal test machine (INSTRON 1mm / min.), immediate and after three and six months. The data were submitted to normality (Shapiro Wilk), and comparative Analysis of variance (two ways: technique and time) and Tukey (p <0.05). Results Immediate values showed no statistically significant difference (p> 0.05), but after three and six months of immersion of the specimens, in distilled water, bond strength values were maintained in the group that received the hydrophobic layer (p<0.05). Conclusion: It was observed that, by incorporating a hydrophobic layer on a universal adhesive system, it was possible to preserve dentin adhesion.