scholarly journals Energy Response of Silicon Drift Detectors for Kaonic Atom Precision Measurements

2019 ◽  
Vol 4 (1) ◽  
pp. 31 ◽  
Author(s):  
Marco Miliucci ◽  
Mihail Iliescu ◽  
Aidin Amirkhani ◽  
Massimiliano Bazzi ◽  
Catalina Curceanu ◽  
...  

Novel, large-area silicon drift detectors (SDDs) have been developed to perform precision measurements of kaonic atom X-ray spectroscopy, for the study the K ¯ N strong interaction in the low-energy regime. These devices have special geometries, field configurations and read-out electronics, resulting in excellent performances in terms of linearity, stability and energy resolution. In this work the SDDs energy response in the energy region between 4000 eV and 12,000 eV is reported, revealing a stable linear response within 1 eV and good energy resolution.

2021 ◽  
Vol 6 (4) ◽  
pp. 47
Author(s):  
Marco Miliucci ◽  
Massimiliano Bazzi ◽  
Damir Bosnar ◽  
Mario Bragadireanu ◽  
Marco Carminati ◽  
...  

A large-area silicon drift detectors (SDDs) system has been developed by the SIDDHARTA-2 collaboration for high precision light kaonic atom X-ray spectroscopy at the DAΦNE collider of Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Frascati. The SDDs’ geometry and electric field configuration, combined with their read-out electronics, make these devices suitable for performing high precision light kaonic atom spectroscopy measurements in the background of the DAΦNE collider. This work presents the spectroscopic response of the SDDs system during the first exotic atoms run of SIDDHARTA-2 with kaonic helium, a preliminary to the kaonic deuterium data taking campaign. The SIDDHARTA-2 spectroscopic system has good energy resolution and a 2 μs timing window which rejects the asynchronous events, scaling the background by a factor of 10−5. The results obtained for the first exotic atoms run of SIDDHARTA-2 prove this system to be ready to perform the challenging kaonic deuterium measurement.


1980 ◽  
Vol 172 (3) ◽  
pp. 471-477 ◽  
Author(s):  
Lo I Yin ◽  
Jacob I. Trombka ◽  
Stephen M. Seltzer

2005 ◽  
Vol 20 (2) ◽  
pp. 185-185
Author(s):  
A. Niculae ◽  
H. Soltau ◽  
P. Lechner ◽  
R. Eckhard ◽  
G. Lutz ◽  
...  

1998 ◽  
Vol 188 ◽  
pp. 335-336
Author(s):  
N. Y. Yamasaki ◽  
T. Ohashi ◽  
K. Kikuchi ◽  
H. Miyazaki ◽  
E. Rokutanda ◽  
...  

STJs are promising X-ray detectors as high energy resolution spectrometers due to the small excitation energy to break the Cooper pairs to product detectable electrons. The expected energy resolution is about 5 eV for a 6 keV incident X-rays (see review by Kraus et al. and Esposito et al.). We have developed a large area (178 × 178μm2) Nb/Al/AlOX/Al/Nb STJs (Kurakado et al. 1993) and series-connected STJs with a position resolution of 35μm for α particles (Kurakado 1997) at Nippon Steel Corporation. As a focal plane detector in future X-ray missions, we are developing STJs whose targert characteristics are; an energy resolution of 20 eV at 6keV, an effective area of 1 cm2, and position resolution of 100μm.


2011 ◽  
Vol 17 (S2) ◽  
pp. 892-893 ◽  
Author(s):  
R Terborg ◽  
J Berlin ◽  
T Salge

Extended abstract of a paper presented at Microscopy and Microanalysis 2011 in Nashville, Tennessee, USA, August 7–August 11, 2011.


2016 ◽  
Vol 872 ◽  
pp. 266-270
Author(s):  
Pruittipol Limkitjaroenporn ◽  
Narong Sangwaranatee ◽  
Wuttichai Chaiphaksa ◽  
Jakrapong Kaewkhao

This article, for comparison, the non-proportionality of light yield and energy resolution of BGO, LYSO and CsI(Tl) scintillators couple to the R1306 PMT readouts were investigated. At 662 keV from 137Cs source, the good energy resolution of 7.13% for CsI(Tl) superior than LYSO and BGO scintillators. The energy resolution on gamma-ray energy was also evaluated to expose the scintillator intrinsic resolution parameters. For non-proportionality of light yield, the study showed a light yield non-proportionality 0.35% of LYSO, the value is better than 4.82 % for CsI(Tl) and 1.53 % of BGO scintillators.


1993 ◽  
Vol 37 ◽  
pp. 405-411
Author(s):  
C. S. Rossington ◽  
N. W. Madden ◽  
K. Chapman

AbstractA new x-ray spectrometer has been constructed which incorporates a novel large area, low capacitance Si(Li) detector and a low noise JFET (junction field effect transistor) preamplifier. The spectrometer operates at high count Tates without the conventional compromise in energy resolution. For example, at an amplifier peaking time of 1 p.sec and a throughput count rate of 145,000 counts sec-1, the energy resolution at 5.9 keV is 220 eV FWHM. Commercially available spectrometers utilizing conventional geometry Si(Li) detectors with areas equivalent to the new detector have resolutions on the order of 540 eV under the same conditions. Conventional x-ray spectrometers offering high energy resolution must employ detectors with areas one-tenth the size of the new LBL detector (20 mm2 compared with 200 mm2). However, even with the use of the smaller area detectors, the energy resolution of a commercial system is typically limited to approximately 300 eV (again, at 1 μsec and 5.9 keV) due to the noise of the commercially available JFET's. The new large area detector is useful in high count rate applications, but is also useful in the detection of weak photon signals, in which it is desirable to subtend as large an angle of the available photon flux as possible, while still maintaining excellent energy resolution. X-ray fluorescence data from die new spectrometer is shown in comparison to a commercially available system in the analysis of a dilute muhi-element material, and also in conjunction with high count rate synchrotron EXAFS applications.


1959 ◽  
Vol 12 (3) ◽  
pp. 231 ◽  
Author(s):  
KH Purser

The cross section of the reaction 6Li(n,3H)'He has been measured, with good energy resolution, over the neutron range 2�0--2�65 MeV. This corresponds to an excitation of 7Li from 9� 0 to 9� 55 MeV, a region in which photodisintegration experiments indicate the presence of one or more levels. No resonance structure was observed in this experiment and possible reasons for this are discussed.