scholarly journals Comparison of N<sub>2</sub>O<sub>5</sub> mixing ratios during NO3Comp 2007 in SAPHIR

2012 ◽  
Vol 5 (11) ◽  
pp. 2763-2777 ◽  
Author(s):  
H. Fuchs ◽  
W. R. Simpson ◽  
R. L. Apodaca ◽  
T. Brauers ◽  
R. C. Cohen ◽  
...  

Abstract. N2O5 detection in the atmosphere has been accomplished using techniques which have been developed during the last decade. Most techniques use a heated inlet to thermally decompose N2O5 to NO3, which can be detected by either cavity based absorption at 662 nm or by laser-induced fluorescence. In summer 2007, a large set of instruments, which were capable of measuring NO3 mixing ratios, were simultaneously deployed in the atmosphere simulation chamber SAPHIR in Jülich, Germany. Some of these instruments measured N2O5 mixing ratios either simultaneously or alternatively. Experiments focused on the investigation of potential interferences from, e.g., water vapour or aerosol and on the investigation of the oxidation of biogenic volatile organic compounds by NO3. The comparison of N2O5 mixing ratios shows an excellent agreement between measurements of instruments applying different techniques (3 cavity ring-down (CRDS) instruments, 2 laser-induced fluorescence (LIF) instruments). Datasets are highly correlated as indicated by the square of the linear correlation coefficients, R2, which values were larger than 0.96 for the entire datasets. N2O5 mixing ratios well agree within the combined accuracy of measurements. Slopes of the linear regression range between 0.87 and 1.26 and intercepts are negligible. The most critical aspect of N2O5 measurements by cavity ring-down instruments is the determination of the inlet and filter transmission efficiency. Measurements here show that the N2O5 inlet transmission efficiency can decrease in the presence of high aerosol loads, and that frequent filter/inlet changing is necessary to quantitatively sample N2O5 in some environments. The analysis of data also demonstrates that a general correction for degrading filter transmission is not applicable for all conditions encountered during this campaign. Besides the effect of a gradual degradation of the inlet transmission efficiency aerosol exposure, no other interference for N2O5 measurements is found.

2012 ◽  
Vol 5 (4) ◽  
pp. 4927-4967 ◽  
Author(s):  
H. Fuchs ◽  
W. R. Simpson ◽  
R. L. Apodaca ◽  
T. Brauers ◽  
R. C. Cohen ◽  
...  

Abstract. N2O5 detection in the atmosphere has been accomplished using techniques which have been developed during the last decade. Most techniques use a heated inlet to thermally decompose N2O5 to NO3, which can be detected by either cavity based absorption at 662 nm or by laser-induced fluorescence. In summer 2007, a large set of instruments, which were capable of measuring NO3 mixing ratios, were simultaneously deployed in the atmosphere simulation chamber SAPHIR in Jülich, Germany. Some of these instruments measured N2O5 mixing ratios either simultaneously or alternatively. Experiments focussed on the investigation of potential interferences from e.g. water vapor or aerosol and on the investigation of the oxidation of biogenic volatile organic compounds by NO3. The comparison of N2O5 mixing ratios shows an excellent agreement between measurements of instruments applying different techniques (3 cavity ring-down (CRDS) instruments, 2 laser-induced fluorescence (LIF) instruments). Data sets are highly correlated as indicated by the square of the linear correlation coefficients, R2, which values are larger than 0.96 for the entire data sets. N2O5 mixing ratios well agree within the combined accuracy of measurements. Slopes of the linear regression range between 0.87 and 1.26 and intercepts are negligible. The most critical aspect of N2O5 measurements by cavity ring-down instruments is the determination of the inlet and filter transmission efficiency. Measurements here show that the N2O5 inlet transmission efficiency can decrease in the presence of high aerosol loads, and that frequent filter/inlet changing is necessary to quantitatively sample N2O5 in some environments. The analysis of data also demonstrates that a general correction for degrading filter transmission is not applicable for all conditions encountered during this campaign. Besides the effect of a gradual degradation of the inlet transmission efficiency aerosol exposure, no other interference for N2O5 measurements is found.


1999 ◽  
Vol 276 (1) ◽  
pp. F172-F177 ◽  
Author(s):  
John N. Lorenz ◽  
Eric Gruenstein

The determination of inulin concentration in nanoliter fluid samples is fundamental to micropuncture investigations of renal function, and this is generally accomplished through the use of radioisotopes. We report here a simple and reliable alternative to the use of radioisotopes that employs FITC-labeled inulin. Samples containing FITC-inulin are stored between oil columns in constant-bore microcapillary tubes, which are then used as cuvettes to determine fluorescence on a microscope fluorometer. Standard curves were generated and found to be linear, with correlation coefficients ( R) exceeding 0.99 in every case. Although the fluorescence of FITC-inulin was found to be pH dependent, the pH and fluorescence of each 20- to 40-nl sample could be normalized by the addition of 1 nl of 0.5 M HEPES at pH 7.5. In mice prepared for standard micropuncture, simultaneous measurements of tubular fluid-to-plasma ratios (TF/P) using FITC-inulin and [125I]iothalamate were highly correlated (slope = 0.95, y-intercept = 0.01, R = 0.942), as were whole kidney measurements of glomerular filtration rate (GFR) (slope = 1.25, y-intercept = −53.5 μl/min, R = 0.99). Micropuncture determinations of late-proximal samples from mice before and after treatment with acetazolamide showed expected changes: TF/P of FITC-inulin decreased from 1.89 ± 0.07 to 1.48 ± 0.10; single-nephron GFR (SNGFR) decreased from 9.64 ± 1.1 to 6.65 ± 1.0 nl/min; and fractional fluid reabsorption decreased from 45.3 ± 1.9 to 26.8 ± 5.2%. Measurements of TF/P of FITC-inulin, volume, and SNGFR using this technique were stable for at least 2 wk when samples were stored in the dark at 4°C. These data demonstrate that this simple method for determining inulin clearance represents a viable and accurate alternative to radioactive methods. This approach has the added benefits of being relatively inexpensive and leaving the micropuncture sample intact.


2000 ◽  
Vol 179 ◽  
pp. 205-208
Author(s):  
Pavel Ambrož ◽  
Alfred Schroll

AbstractPrecise measurements of heliographic position of solar filaments were used for determination of the proper motion of solar filaments on the time-scale of days. The filaments have a tendency to make a shaking or waving of the external structure and to make a general movement of whole filament body, coinciding with the transport of the magnetic flux in the photosphere. The velocity scatter of individual measured points is about one order higher than the accuracy of measurements.


1996 ◽  
Vol 75 (05) ◽  
pp. 772-777 ◽  
Author(s):  
Sybille Albrecht ◽  
Matthias Kotzsch ◽  
Gabriele Siegert ◽  
Thomas Luther ◽  
Heinz Großmann ◽  
...  

SummaryThe plasma tissue factor (TF) concentration was correlated to factor VII concentration (FVIIag) and factor VII activity (FVIIc) in 498 healthy volunteers ranging in age from 17 to 64 years. Immunoassays using monoclonal antibodies (mAbs) were developed for the determination of TF and FVIIag in plasma. The mAbs and the test systems were characterized. The mean value of the TF concentration was 172 ± 135 pg/ml. TF showed no age- and gender-related differences. For the total population, FVIIc, determined by a clotting test, was 110 ± 15% and the factor VIlag was 0.77 ± 0.19 μg/ml. FVII activity was significantly increased with age, whereas the concentration demonstrated no correlation to age in this population. FVII concentration is highly correlated with the activity as measured by clotting assay using rabbit thromboplastin. The ratio between FVIIc and FVIIag was not age-dependent, but demonstrated a significant difference between men and women. Between TF and FVII we could not detect a correlation.


The present study explored the relationship between spot and futures coffee prices. The Correlation and Regression analysis were carried out based on monthly observations of International Coffee Organization (ICO) indicator prices of the four groups (Colombian Milds, Other Milds, Brazilian Naturals, and Robustas) representing Spot markets and the averages of 2nd and 3rd positions of the Intercontinental Exchange (ICE) New York for Arabica and ICE Europe for Robusta representing the Futures market for the period 1990 to 2019. The study also used the monthly average prices paid to coffee growers in India from 1990 to 2019. The estimated correlation coefficients indicated both the Futures prices and Spot prices of coffee are highly correlated. Further, estimated regression coefficients revealed a very strong relationship between Futures prices and Spot prices for all four ICO group indicator prices. Hence, the ICE New York (Arabica) and ICE Europe (Robusta) coffee futures prices are very closely related to Spot prices. The estimated regression coefficients between Futures prices and the price paid to coffee growers in India confirmed the positive relationship, but the dispersion of more prices over the trend line indicates a lesser degree of correlation between the price paid to growers at India and Futures market prices during the study period.


2021 ◽  
Vol 13 (5) ◽  
pp. 892
Author(s):  
Xiaomei Li ◽  
Pinhua Xie ◽  
Ang Li ◽  
Jin Xu ◽  
Zhaokun Hu ◽  
...  

This paper studied the method for converting the aerosol extinction to the mass concentration of particulate matter (PM) and obtained the spatio-temporal distribution and transportation of aerosol, nitrogen dioxide (NO2), sulfur dioxide (SO2), and formaldehyde (HCHO) based on multi-axis differential optical absorption spectroscopy (MAX-DOAS) observations in Dalian (38.85°N, 121.36°E), Qingdao (36.35°N, 120.69°E), and Shanghai (31.60°N, 121.80°E) from 2019 to 2020. The PM2.5 measured by the in situ instrument and the PM2.5 simulated by the conversion formula showed a good correlation. The correlation coefficients R were 0.93 (Dalian), 0.90 (Qingdao), and 0.88 (Shanghai). A regular seasonality of the three trace gases is found, but not for aerosols. Considerable amplitudes in the weekly cycles were determined for NO2 and aerosols, but not for SO2 and HCHO. The aerosol profiles were nearly Gaussian, and the shapes of the trace gas profiles were nearly exponential, except for SO2 in Shanghai and HCHO in Qingdao. PM2.5 presented the largest transport flux, followed by NO2 and SO2. The main transport flux was the output flux from inland to sea in spring and winter. The MAX-DOAS and the Copernicus Atmosphere Monitoring Service (CAMS) models’ results were compared. The overestimation of NO2 and SO2 by CAMS is due to its overestimation of near-surface gas volume mixing ratios.


1997 ◽  
Vol 16 (11) ◽  
pp. 667-672 ◽  
Author(s):  
S. Halbach ◽  
L. Kremers ◽  
H. Willruth ◽  
A. Mehl ◽  
G. Welzl ◽  
...  

The number of amalgam-covered surfaces and the occlusal area of the fillings, the concentrations of total mercury in plasma, erythrocytes and urine, the urinary excretion rate, and the absorbed daily doses estimated by two separate methods from intra-oral Hg emission were determined in 29 volunteers with a low amalgam load. The transfer ofHg from the fillings via the oral cavity and blood to urinary excretion was evaluated by multiple correla tions between these variables. In addition, the combina tion of variables most representative of the entire compartmental transfer of amalgam Hg was determined. Urinary excretion (1), Hg concentration in plasma (2) and absorbed dose (3) were most closely correlated to each other, followed by correlations with the variables of the fillings (4). Correlation coefficients were 0.75 for variables 1 vs 2 and 2 vs 3, and 0.49 for variables 3 vs 4. It was concluded that variables 1-3 best reflected the transfer of mercury from amalgam fillings throughout the organism and that they were relatively insensitive to dietary mercury. The determination of total mercury in plasma and of its urinary excretion rate appears, under practical aspects, most suitable for the investigation of Hg uptake from amalgam.


Sign in / Sign up

Export Citation Format

Share Document