solid contact
Recently Published Documents


TOTAL DOCUMENTS

572
(FIVE YEARS 141)

H-INDEX

43
(FIVE YEARS 9)

Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 579
Author(s):  
Paweł Kościelniak ◽  
Marek Dębosz ◽  
Marcin Wieczorek ◽  
Jan Migdalski ◽  
Monika Szufla ◽  
...  

A solid-contact ion-selective electrode was developed for detecting potassium in environmental water. Two versions of a stable cadmium acylhydrazone-based metal organic framework, i.e., JUK-13 and JUK-13_H2O, were used for the construction of the mediation layer. The potentiometric and electrochemical characterizations of the proposed electrodes were carried out. The implementation of the JUK-13_H2O interlayer is shown to improve the potentiometric response and stability of measured potential. The electrode exhibits a good Nernstian slope (56.30 mV/decade) in the concentration range from 10−5 to 10−1 mol L−1 with a detection limit of 2.1 µmol L−1. The long-term potential stability shows a small drift of 0.32 mV h−1 over 67 h. The electrode displays a good selectivity comparable to ion-selective electrodes with the same membrane. The K-JUK-13_H2O-ISE was successfully applied for the determination of potassium in three certified reference materials of environmental water with great precision (RSD < 3.00%) and accuracy (RE < 3.00%).


2022 ◽  
Vol 934 ◽  
Author(s):  
Hatef Rahmani ◽  
Boris Stoeber ◽  
Neil J. Balmforth ◽  
Sheldon I. Green

Experiments are conducted to explore the rolling of a cylinder over a pool of viscous fluid. The speed, width and loading of the cylinder are varied along with the initial depth and length of the viscous pool. Depending on the conditions, the cylinder will either ride on a lubrication film or remain in solid contact with the underlying substrate. For the former situation, a lubrication theory is presented that describes the pressure underneath the cylinder and the thickness of the film. The theory approximates the flow by the one-dimensional Reynolds equation with the addition of one term, with an adjustable parameter, to account for the flux of fluid to the cylinder sides. Once this parameter is calibrated against experiment, the theory predicts peak lubrication pressures, gap sizes and film thicknesses to within approximately ten per cent. For lubricated rolling, the film splits evenly between the cylinder and substrate downstream of the nip. The printer's instability arises during the splitting process, patterning the residual fluid films on the substrate and cylinder. If the pool length is less than the cylinder circumference, the fluid adhering to the cylinder is rotated back into contact with the substrate, and when there is sufficient adhered fluid a lubrication film forms that can again be modelled by the theory. Conversely, if there is insufficient adhered fluid, no contiguous lubrication film is formed; instead, the pattern from the printer's instability ‘prints’ from the cylinder to the substrate.


2022 ◽  
pp. 131416
Author(s):  
Tingting Han ◽  
Andrey V. Kalinichev ◽  
Zekra Mousavi ◽  
Konstantin N. Mikhelson ◽  
Johan Bobacka

Author(s):  
Elena Zdrachek ◽  
Tara Forrest ◽  
Eric Bakker
Keyword(s):  

Membranes ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 959
Author(s):  
Chunxian Liao ◽  
Lijie Zhong ◽  
Yitian Tang ◽  
Zhonghui Sun ◽  
Kanglong Lin ◽  
...  

Current solid potentiometric ion sensors mostly rely on polymeric-membrane-based, solid-contact, ion-selective electrodes (SC-ISEs). However, anion sensing has been a challenge with respect to cations due to the rareness of anion ionophores. Classic metal/metal insoluble salt electrodes (such as Ag/AgCl) without an ion-selective membrane (ISM) offer an alternative. In this work, we first compared the two types of SC-ISEs of Cl− with/without the ISM. It is found that the ISM-free Ag/AgCl electrode discloses a comparable selectivity regarding organic chloride ionophores. Additionally, the electrode exhibits better comprehensive performances (stability, reproducibility, and anti-interference ability) than the ISM-based SC-ISE. In addition to Cl−, other Ag/AgX electrodes also work toward single and multi-valent anions sensing. Finally, a flexible Cl− sensor was fabricated for on-body monitoring the concentration of sweat Cl− to illustrate a proof-of-concept application in wearable anion sensors. This work re-emphasizes the ISM-free SC-ISEs for solid anion sensing.


2021 ◽  
Vol 2119 (1) ◽  
pp. 012079
Author(s):  
I P Starodubtseva ◽  
A N Pavlenko

Abstract The results of computational experiments simulating the triggering of the quench front propagation on the superheated vertically oriented metal plates are presented. The plates are quenched by a gravitationally flowing down liquid nitrogen film. The temperature of the test samples at the beginning of the process was higher than the critical temperature and the Leidenfrost temperature, which means that direct long-term liquid-solid contact is impossible. For this reason, the front is initially motionless. As a result of numerical simulation, a dynamic pattern of the quench front propagation on a high-temperature surface was obtained. Analysis of the results allowed to find the realistic values of heat sink into the cooling medium, as well as the parameters of the local temperature disturbance, its spatial extent and amplitude, at which the conditions are created for triggering the process of quench front propagation on the high-temperature surface. Direct comparison of the numerical simulations results with experimental data on the velocity, geometry of the quench front and on the dynamical pattern of the process confirmed the reliability of the results obtained.


Author(s):  
Karolina Pietrzak ◽  
Cecylia Wardak ◽  
Szymon Malinowski

AbstractThe application of polyaniline nanofibers doped with chloride and nitrate ions (PANINFs-Cl and PANINFs-NO3) in potentiometry was described. Both kinds of nanofibers were used as an ion-to-electron transducer in ion-selective electrodes with solid contact (SCISEs). Extensive research on the properties of the nanofibers themselves (SEM, UV–Vis spectroscopy, FTIR) and the constructed electrodes (potentiometric methods, electrochemical impedance spectroscopy) has been carried out. Basic analytical parameters of electrodes containing various nanofibers contents in the ion-selective membrane and with nanofibers as an intermediate layer were determined. It was found that application of PANI nanofibers resulted in improvement of electrode performance (among others, better stability and reversibility of the electrode potential). The obtained sensors were characterized by a high slope of the calibration curve, a wide measuring range and a fast response time. Moreover, they were insensitive to change of redox potential, as well as light and the presence of oxygen in the solution, what is important from a practical point of view. They were also successfully used for nitrate determination in real environmental samples.


Talanta ◽  
2021 ◽  
pp. 123114
Author(s):  
Xiaotong Sun ◽  
Tanji Yin ◽  
Ziping Zhang ◽  
Wei Qin

Sign in / Sign up

Export Citation Format

Share Document