nernstian slope
Recently Published Documents


TOTAL DOCUMENTS

43
(FIVE YEARS 14)

H-INDEX

6
(FIVE YEARS 3)

Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 579
Author(s):  
Paweł Kościelniak ◽  
Marek Dębosz ◽  
Marcin Wieczorek ◽  
Jan Migdalski ◽  
Monika Szufla ◽  
...  

A solid-contact ion-selective electrode was developed for detecting potassium in environmental water. Two versions of a stable cadmium acylhydrazone-based metal organic framework, i.e., JUK-13 and JUK-13_H2O, were used for the construction of the mediation layer. The potentiometric and electrochemical characterizations of the proposed electrodes were carried out. The implementation of the JUK-13_H2O interlayer is shown to improve the potentiometric response and stability of measured potential. The electrode exhibits a good Nernstian slope (56.30 mV/decade) in the concentration range from 10−5 to 10−1 mol L−1 with a detection limit of 2.1 µmol L−1. The long-term potential stability shows a small drift of 0.32 mV h−1 over 67 h. The electrode displays a good selectivity comparable to ion-selective electrodes with the same membrane. The K-JUK-13_H2O-ISE was successfully applied for the determination of potassium in three certified reference materials of environmental water with great precision (RSD < 3.00%) and accuracy (RE < 3.00%).


2021 ◽  
Vol 21 (6) ◽  
pp. 1491
Author(s):  
Gamal Abdel-Hafiz Mostafa ◽  
Hazem Mohamed Abu Shawish ◽  
Salman Mustafa Saadeh ◽  
Essam Ezzeldin

Utilizing the well-known ability of Schiff base ligands to bind metal ions, two newly fabricated ligands, namely: 2-((2-hydroxybenzylidene)amino)benzoic acid (L1) and 2-(furan-2-ylmethyleneamino)phenol (L2) were employed to coordinate copper(II) (Cu(II)) producing the characteristically stable complexes that performed as the ionophores in the presently fabricated electrodes A and B. Thus it was possible to build these electrodes that have attractive properties and expected behavior, namely, low detection limits: 2.32 × 10–7 and 1.14 × 10–6 M Cu(II), Nernstian slope of 29.13 and 30.85 mV/decade Cu(II), broad concentration ranges from 3.98 × 10–7–1.00 × 10–2 and 1.52 × 10–6–1.00 × 10–2 M for sensors A and B, respectively, as well as short response time (ca. 3–5 s) with distinct selectivity toward Cu(II) over the other cations and applicability over the pH range 1.5–5.5 for miscellaneous samples: aqueous solutions, urine, and blood serum. Thus, these sensors surpass many others towards fulfilling the intended function of Cu(II) determination in various applications.


Molecules ◽  
2021 ◽  
Vol 26 (16) ◽  
pp. 5093
Author(s):  
Sherif A. Abdel-Gawad ◽  
Obaid Afzal ◽  
Hany H. Arab ◽  
Alhumaidi B. Alabbas ◽  
Abdulmalik M. Alqarni

Accurate and precise application of ion-selective electrodes (ISEs) in the quantification of environmental pollutants is a strenuous task. In this work, the electrochemical response of alendronate sodium trihydrate (ALN) was evaluated by the fabrication of two sensitive and delicate membrane electrodes, viz. polyvinyl chloride (PVC) and glassy carbon (GC) electrodes. A linear response was obtained at concentrations from 1 × 10−5 to 1 × 10−2 M for both electrodes. A Nernstian slope of 29 mV/decade over a pH range of 8–11 for the PVC and GC membrane electrodes was obtained. All assay settings were carefully adjusted to obtain the best electrochemical response. The proposed technique was effectively applied for the quantification of ALN in pure form and wastewater samples, acquired from manufacturing industries. The proposed electrodes were effectively used for the determination of ALN in real wastewater samples without any prior treatment. The current findings guarantee the applicability of the fabricated ISEs for the environmental monitoring of ALN.


Molecules ◽  
2021 ◽  
Vol 26 (12) ◽  
pp. 3627
Author(s):  
Nikola Sakač ◽  
Dubravka Madunić-Čačić ◽  
Dean Marković ◽  
Lucija Hok ◽  
Robert Vianello ◽  
...  

A 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DHBI-TPB) ion-pair implemented in DHBI-TPB surfactant sensor was used for the potentiometric quantification of anionic surfactants in detergents and commercial household care products. The DHBI-TPB ion-pair was characterized by FTIR spectroscopy and computational analysis which revealed a crucial contribution of the C–H∙∙∙π contacts for the optimal complex formation. The DHBI-TPB sensor potentiometric response showed excellent analytical properties and Nernstian slope for SDS (60.1 mV/decade) with LOD 3.2 × 10−7 M; and DBS (58.4 mV/decade) with LOD 6.1 × 10−7 M was obtained. The sensor possesses exceptional resistance to different organic and inorganic interferences in broad pH (2–10) range. DMIC used as a titrant demonstrated superior analytical performances for potentiometric titrations of SDS, compared to other tested cationic surfactants (DMIC > CTAB > CPC > Hyamine 1622). The combination of DHBI-TPB sensor and DMIC was successfully employed to perform titrations of the highly soluble alkane sulfonate homologues. Nonionic surfactants (increased concentration and number of EO groups) had a negative impact on anionic surfactant titration curves and a signal change. The DHBI-TPB sensor was effectively employed for the determination of technical grade anionic surfactants presenting the recoveries from 99.5 to 101.3%. The sensor was applied on twelve powered samples as well as liquid-gel and handwashing home care detergents containing anionic surfactants. The obtained results showed good agreement compared to the outcomes measured by ISE surfactant sensor and a two-phase titration method. The developed DHBI-TPB surfactant sensor could be used for quality control in industry and has great potential in environmental monitoring.


Author(s):  
Fatehy M. Abdel-Haleem ◽  
Eman Gamal ◽  
Mahmoud S. Rizk ◽  
Adel Madbouly ◽  
Rasha M. El Nashar ◽  
...  

Ivabradine hydrochloride (IVR) is a medically important drug because of its ability to lower the heart rate. Techniques reported for IVR determination were expensive, laborious, besides being of poor selectivity. In this study, iron oxide @ carbon nanotube (Fe2O3@MWCNTs) nanocomposite and molecularly imprinted polymer (MIP) were synthesized and used in the fabrication of carbon paste electrodes (CPEs) for the potentiometric detection of IVR in biological and pharmaceutical samples. CPEs of the best sensor were formulated from graphite (41 wt%) as a carbon source, MIP (3 wt.%) as an ionophore, Fe2O3@MWCNTs (5 wt%) as a modifier, and nitrophenyl octyl ether (NPOE, 51 wt.%) as a conductive oil so-called plasticizer. The best sensor exhibits a Nernstian slope (response) of 56 mV decade–1 within the IVR concentration range from 1.0 × 10–3 M to 9.8 × 10–8 M with high selectivity against interfering species (ascorbic, maltose, glucose, lactose, dopamine, glycine) over those reported earlier. The use of Fe2O3@MWCNTs together with MIP in the electrode formulation was found to improve the limit of detection (LOD) from 630 to 98 nM along with high reversibility, a short response time of 30 s, and a good lifetime of more than 2 weeks. The sandwich membrane (SMM) method was used to quantify the H-bonding complexing strength of the MIP binding sites for IVR with Log βILn = 11.33. The constructed sensors were successfully applied for the IVR determination in blood serum, urine, and commercial formulations (Savapran®) with high sensitivity.


Chemosensors ◽  
2021 ◽  
Vol 9 (3) ◽  
pp. 52
Author(s):  
Nermine V. Fares ◽  
Passant M. Medhat ◽  
Christine M. El Maraghy ◽  
Sherif Okeil ◽  
Miriam F. Ayad

Two inexpensive and simple methods for synthesis of carbon nanodots were applied and compared to each other, namely a hydrothermal and microwave-assisted method. The synthesized carbon nanodots were characterized using transmission electron microscopy (TEM), ultraviolet-visible (UV-Vis), photoluminescence (PL), Fourier transform-infrared spectroscopy (FTIR), and X-ray diffraction (XRD). The synthesized microwave carbon nanodots had smaller particle size and were thus chosen for better electrochemical performance. Therefore, they were used for our modification process. The proposed electrodes performance characteristics were evaluated according to the IUPAC guidelines, showing linear response in the concentration range 10−6–10−2, 10−7–10−2, and 10−8–10−2 M of tobramycin with a Nernstian slope of 52.60, 58.34, and 57.32 mV/decade for the bare, silver nanoparticle and carbon nanodots modified carbon paste electrodes, respectively. This developed potentiometric method was used for quantification of tobramycin in its co-formulated dosage form and spiked human plasma with good recovery percentages and without interference of the co-formulated drug loteprednol etabonate and excipients.


Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6375
Author(s):  
Junghwan Kim ◽  
Dae Hee Kim ◽  
Jin Cheol Yang ◽  
Jae Sang Kim ◽  
Ji Ha Lee ◽  
...  

A beryllium(II)-ion-selective poly(ethylenedioxythiophene) (PEDOT) solid contact electrode comprising 9,10-dinitrobenzo-9-crown-3-ether was successfully developed. The all-solid-state contact electrode, with an oxygen-containing cation-sensing membrane combined with an electropolymerized PEDOT layer, exhibited the best response characteristics. The performance of the constructed electrode was evaluated and optimized using potentiometry, conductance measurements, constant-current chronopotentiometry, and electrochemical impedance spectroscopy (EIS). Under optimized conditions, which were found for an ion-selective membrane (ISM) composition of 3% ionophore, 30% polyvinylchloride (PVC), 64% o-nitro phenyl octyl ether (o-NPOE), and 3% sodium tetraphenylborate (NaTPB), the fabricated electrode exhibited a good performance over a wide concentration range (10−2.5–10−7.0 M) and a wide pH range of 2.0–9.0, with a Nernstian slope of 29.5 mV/D for the beryllium (II) ion and a detection limit as low as 10−7.0 M. The developed electrode shows good selectivity for the beryllium(II) ion over alkali, alkaline earth, transition, and heavy metal ions.


2020 ◽  
Vol 11 (1) ◽  
pp. 21-29 ◽  
Author(s):  
Iyad Darweesh Al-Kashef ◽  
Salman Mostafa Saadeh ◽  
Khalid Ibrahim Abed Almonem ◽  
Nasser Mohammed Abu Ghalwa ◽  
Hazem Mohammed Abu Shawish

Accurate, rapid and inexpensive determination of gemcitabine, an anticancer drug, is of high interest. This manuscript describes the use of potentiometric sensors as a basis for this work given their known attractive characteristics that meet our needs. Potentiometric sensors were comprised of carbon paste S1, coated wire S2 and PVC membrane S3, of gemcitabine (an anticancer drug) were fabricated, studied and evaluated. The calibration plots for these electrodes showed a Nernstian slope of 58.4±0.3, 59.5±0.3 and 58.3±0.3 mV per decade with the limit of detection: 6.50×10-5, 7.20×10-5 and 4.60×10-5 for sensors S1, S2 and S3, respectively. The electrodes have a short and stable response time of ~5 seconds and good reproducibility in a pH range of 2.5-9.5. The present sensors show distinct selectivity toward the drug ion in comparison to several inorganic ions, sugars, amino acids and some common drug excipients. Gemcitabine was determined successfully in ampoules and urine using these sensors by the calibration curve method.


Nanomaterials ◽  
2020 ◽  
Vol 10 (3) ◽  
pp. 572 ◽  
Author(s):  
Saad S.M. Hassan ◽  
Ayman H. Kamel ◽  
Abd El-Galil E. Amr ◽  
Heba M. Hashem ◽  
E.M. Abdel Bary

Herein, we present a new validated potentiometric method for fluoxetine (FLX) drug monitoring. The method is based on the integration of molecular imprinting polymer (MIP) beads as sensory elements with modified screen-printed solid contact ion-selective electrodes (ISEs). A multi-walled carbon nanotube (MWCNT) was used as a nanomaterial for the ion-to-electron transduction process. The prepared MIP beads depend on the use of acrylamide (AAm) and ethylene glycol dimethacrylic acid (EGDMA) as a functional monomer and cross-linker, respectively. The sensor revealed a stable response with a Nernstian slope of 58.9 ± 0.2 mV/decade and a detection limit of 2.1 × 10−6 mol/L in 10 mmol/L acetate buffer of pH 4.5. The presented miniaturized sensors revealed good selectivity towards FLX over many organic and inorganic cations, as well as some additives encountered in the pharmaceutical preparations. Repeatability, reproducibility and stability have been studied to evaluate the analytical features of the presented sensors. These sensors were successfully applied for FLX assessment in different pharmaceutical formulations collected from the Egyptian local market. The obtained results agreed well with the acceptable recovery percentage and were better than those obtained by other previously reported routine methods.


2020 ◽  
Vol 92 (4) ◽  
pp. 2926-2930 ◽  
Author(s):  
Elena Zdrachek ◽  
Eric Bakker

Sign in / Sign up

Export Citation Format