scintillation crystal
Recently Published Documents


TOTAL DOCUMENTS

149
(FIVE YEARS 20)

H-INDEX

17
(FIVE YEARS 3)

2021 ◽  
pp. 110053
Author(s):  
A. El Hamli ◽  
A. Bazza ◽  
A. Moussa ◽  
M. Hamal ◽  
M. Zerfaoui ◽  
...  

Universe ◽  
2021 ◽  
Vol 7 (11) ◽  
pp. 396
Author(s):  
Minbin Kim ◽  
Jakub Ripa ◽  
Il H. Park ◽  
Vitaly Bogomolov ◽  
Søren Brandt ◽  
...  

We developed an X-ray detector using 36 arrays, each consisting of a 64-pixellated yttrium oxyorthosilicate (YSO) scintillation crystal and a 64-channel multi-anode photomultiplier tube. The X-ray detector was designed to detect X-rays with energies lower than 10 keV, primarily with the aim of localizing gamma-ray bursts (GRBs). YSO crystals have no intrinsic background, which is advantageous for increasing low-energy sensitivity. The fabricated detector was integrated into UBAT, the payload of the Ultra-Fast Flash Observatory (UFFO)/Lomonosov for GRB observation. The UFFO was successfully operated in space in a low-Earth orbit. In this paper, we present the responses of the X-ray detector of the UBAT engineering model identical to the flight model, using 241Am and 55Fe radioactive sources and an Amptek X-ray tube. We found that the X-ray detector can measure energies lower than 5 keV. As such, we expect YSO crystals to be good candidates for the X-ray detector materials for future GRB missions.


Author(s):  
T. Jomkaew ◽  
W. Chaiphaksa ◽  
K. Siengsanoh ◽  
P. Limkitjaroenporn ◽  
C. Kedkaew ◽  
...  

2021 ◽  
Vol 183 ◽  
pp. 109396
Author(s):  
Chanho Kim ◽  
Dongyoung Kim ◽  
Yeeeun Lee ◽  
Chansun Park ◽  
Muhammad Nasir Ullah ◽  
...  

2021 ◽  
Vol 253 ◽  
pp. 09004
Author(s):  
A. Ros ◽  
L. Barrientos ◽  
M. Borja-Lloret ◽  
J.V. Casaña ◽  
E. Muñoz ◽  
...  

In recent decades, PET scanners have been widely used for diagnosis and treatment monitoring in nuclear medicine. The continuous effort of the scientific community has led to improvements in scanner performance. Total-body PET is one of the latest upgrades in PET scanners. These kinds of scanners are able to scan the whole body of the patient with a single bed position, since the scanner tube is long enough for the patient to fit inside. While these scanners show unprecedented efficiency and extended field-of-view, a drawback is their low spatial resolution compared to dedicated scanners. In order to improve the spatial resolution of specific areas when measuring with a total-body PET scanner, the IRIS group at IFIC-Valencia is developing a probe. The proposed setup of the probe contains a monolithic scintillation crystal and a SiPM. The signal of the probe is read out by a TOFPET2 ASIC from PETsys, which has shown good performance for PET in terms of spatial and time resolutions. Furthermore, the PETsys technology generates a trigger signal that will be used to time synchronise the probe and the scanner. The proof-of-concept of the probe will be tested in a Preclinical Super Argus PET/CT scanner for small animals located at IFIC. Preliminary simulations of the scanner and the probe under ideal conditions show a slight improvement in the position reconstruction compared to the data obtained with the scanner, therefore we expect a considerable improvement when using the probe in a total-body PET scanner. Characterisation tests of the probe have been performed with a 22Na point-like source, obtaining an energy resolution of 9.09% for the 511 keV energy peak and a temporal resolution of 619 ps after time walk correction. The next step of the project is to test the probe measuring in temporal coincidence with the scanner.


Author(s):  
Richard S. Woolf ◽  
Bernard F. Phlips ◽  
Anthony L. Hutcheson ◽  
Lee J. Mitchell ◽  
Eric A. Wulf

2020 ◽  
Vol 56 (8) ◽  
pp. 867-874
Author(s):  
I. I. Novoselov ◽  
O. V. Gileva ◽  
J. S. Choe ◽  
K. A. Shin ◽  
V. N. Shlegel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document