symmetry index
Recently Published Documents


TOTAL DOCUMENTS

105
(FIVE YEARS 55)

H-INDEX

12
(FIVE YEARS 3)

2021 ◽  
pp. 112067212110601
Author(s):  
Abdelrahman Salman ◽  
Taym Darwish ◽  
Ali Ali ◽  
Marwan Ghabra ◽  
Rafea Shaaban

Aim To estimate the sensitivity and specificity of topographic and tomographic corneal parameters as determined by Sirius (CSO, Florence, Italy) in discriminating keratoconus (KC) and suspect keratoconus from normal cornea. Method In this retrospective case-series study, keratoconus screening indices were measured using Sirius tomographer. Receiver operating characteristics (ROC) curves were used to determine the test's overall predictive accuracy (area under the curve) and to identify optimal cut-off points to maximize sensitivity and specificity in differentiating keratoconus and suspect keratoconus from normal corneas. Results Receiver operating characteristics (ROC) curve analyses showed high predictive accuracy for Symmetry Index back (SIb), Keratoconus Vertex front (KVf), Symmetry Index front (SIf), Keratoconus Vertex back (KVb), Apex Keratometry (Curve-Apex) and Minimum corneal Thickness (ThkMin) to distinguish keratoconus from normal (area under the curve > 0.9, all). Symmetry Index back was identified as the best diagnostic parameter for detecting suspect keratoconus with AUC of 0.86. Highest specificity to detect keratoconus and suspect keratoconus was seen for SIb, 99.87% and 84.66%, respectively. These values were associated with optimal cut-off points of 0.46 D for keratoconus and 0.12 D for suspect keratoconus. Conclusion Sirius parameters evaluated in the study were effective to differentiate keratoconus from normal corneas. However, Symmetry Index back was the index with the highest ability to detect suspect keratoconus.


SLEEP ◽  
2021 ◽  
Author(s):  
Soraia Ventura ◽  
Sean R Mathieson ◽  
John M O’Toole ◽  
Vicki Livingstone ◽  
Mary-Anne Ryan ◽  
...  

Abstract Study Objectives Sleep features in infancy are potential biomarkers for brain maturation but poorly characterised. We describe normative values for sleep macrostructure and sleep spindles at 4-5 months of age. Methods Healthy term infants were recruited at birth and had daytime sleep EEGs at 4-5 months. Sleep staging was performed and 5 features were analysed. Sleep spindles were annotated and 7 quantitative features were extracted. Features were analysed across sex, recording time (am/pm), infant age and from first to second sleep cycles. Results We analysed sleep recordings from 91 infants, 41% girls. Median (IQR) macrostructure results: sleep duration 49.0 (37.8-72.0) minutes (n=77); first sleep cycle duration 42.8 (37.0 – 51.4) minutes; REM percentage 17.4 (9.5 - 27.7)% (n=68); latency to REM 36.0 (30.5-41.1) minutes (n=66). First cycle median (IQR) values for spindle features: number 241.0 (193.0-286.5), density 6.6 (5.7-8.0) spindles.min -1(n=77); mean frequency 13.0 (12.8-13.3) Hz, mean duration 2.9 (2.6-3.6)s, spectral power 7.8 (4.7-11.4)µV 2, brain symmetry index 0.20 (0.16-0.29), synchrony 59.5 (53.2-63.8)% (n=91). In males, spindle spectral power (µV 2) is 24.5% lower (p=0.032) and brain symmetry index 24.2% higher than females (p=0.011) when controlling for gestational and postnatal age and timing of the nap. We found no other significant associations between studied sleep features and sex, recording time (am/pm), or age. Spectral power decreased (p<0.001) on the second cycle. Conclusion This normative data may be useful for comparison with future studies of sleep dysfunction and atypical neurodevelopment in infancy.


Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7476
Author(s):  
Enrique Panera-Rico ◽  
José Manuel Castillo-López ◽  
Inmaculada Concepción Palomo-Toucedo ◽  
Fernando Chacón-Giráldez ◽  
Javier Ramos-Ortega ◽  
...  

Techniques of taking casts mainly rely not on the objectivity of the procedure, but on the experience and skill of the technician. The aim of this study was to demonstrate the efficiency of a technique of taking standing foot casts controlled via pressure sensors. In this way, we mean to objectivize the degree of correction. The study was carried out through 150 procedures on 50 feet of 29 patients. The value of the “Heel Symmetry Index” was calculated on three casts in three different situations of the same foot: A first cast in which the subject did not control the position of his/her foot; a second cast where manipulations corrected the foot’s pronator position; and a third cast with pressure sensors placed in the subject’s heel. This enabled the control and quantification of the pressure during the manipulation when taking the cast. The comparison of the “Heel Symmetry Index” in the different groups showed significant p-values of 0.05. Conclusion: The technique of taking casts controlled by pressure sensors achieved more equilibrated casts with a better symmetry index of the heel’s outline.


2021 ◽  
Author(s):  
Ningning Wang ◽  
Jun Liang ◽  
Hengyu Zhang ◽  
Chunxiao Wan ◽  
Shizhong Liu ◽  
...  

Author(s):  
Hannah Lena Siebers ◽  
Waleed Alrawashdeh ◽  
Marcel Betsch ◽  
Filippo Migliorini ◽  
Frank Hildebrand ◽  
...  

Abstract Background Symmetry is a sign of physiological and healthy movements, as pathologies are often described by increased asymmetries. Nevertheless, based on precisely measured data, even healthy individuals will show small asymmetries in their movements. However, so far there do not exist commonly accepted methods and reference values for gait symmetry in a healthy collective. Therefore, a comparison and presentation of reference values calculated by 3 different methods of symmetry indices for lower limb joint angles during walking, ascending, and descending stairs were shown. Methods Thirty-five healthy participants were analyzed during walking, ascending, and descending stairs with the help of the inertial measurement system MyoMotion. Using the normalized symmetry index (SInorm), the symmetry index (SI) as the integral of the symmetry function, and another normalized symmetry index (NSI), the symmetry of joint angles was evaluated. For statistical evaluation of differences, repeated measurement models and Bland–Altman-Plots were used. Results Apart from a bias between the symmetry indices, they were comparable in the predefined limits of 5%. For all parameters, significantly higher asymmetry was found for ankle dorsi/-plantarflexion, compared with the hip and knee flexion. Moreover, the interaction effect of the joint and movement factors was significant, with an increased asymmetry of the hip and knee during descending stairs greater than while ascending stairs or walking, but a reduced symmetry of the ankle during walking when compared to descending. The movement only showed significant effects when analyzing the SInorm. Conclusion Even for healthy individuals, small asymmetries of movements were found and presented as reference values using 3 different symmetry indices for dynamic lower limb joint angles during 3 different movements. For the quantification of symmetrical movements differences between the joints, movements, and especially their interaction, are necessary to be taken into account. Moreover, a bias between the methods should be noted. The potential for each presented symmetry index to identify pathological movements or track a rehabilitation process was shown but has to be proven in further research. Trial registration: DRKS00025878.


Sensors ◽  
2021 ◽  
Vol 21 (19) ◽  
pp. 6423
Author(s):  
Ewa Gieysztor ◽  
Mateusz Kowal ◽  
Małgorzata Paprocka-Borowicz

Background: The objective gait assessment in children has become more popular. Basis parameters for comparison during the examination are advisable. Objectives: The study aim was to investigate the typical gait parameters of healthy preschool and school children, using a wireless inertial sensor as the reference for atypical gait. The additional aim was to compare the specific gait parameters in the younger and older group of children. Methods: One hundred and sixty-one children’s gait parameters were evaluated by a G-Walk BTS G-SENSOR smart analyzer. The children were walking barefoot, at a self-selected speed, on a five-meter walkway, and they turned around and go back twice. Results: Age significantly influences most of the spatiotemporal parameters. The support phase becomes shorter with age. Accordingly, the swing phase becomes longer with age. The results also show that older children need shorter double support and have longer single support. Moreover, the pelvic tilt symmetry index is higher with increasing age. In each age division, the smallest variation in all gait parameters within the oldest group of examined children was observed. A comparison between the left and right side gait parameters shows the higher difference in boys than in girls. A significant difference was calculated in the pelvic obliquity symmetry index. Girls had significantly more symmetrical obliquity than boys. Conclusions: the research indicates the basic parameters of typical children’s gait, which may be a reference to atypical gait in the case of trauma or disability.


2021 ◽  
Vol 2021 ◽  
pp. 1-16
Author(s):  
Ju-Yul Yoon ◽  
Da-Sol Kim ◽  
Gi-Wook Kim ◽  
Myoung-Hwan Ko ◽  
Jeong-Hwan Seo ◽  
...  

Objective. Schizencephaly is a rare congenital malformation that causes motor impairment. To determine the treatment strategy, each domain of the motor functions should be appropriately evaluated. We correlated a color map of diffusion tensor imaging (DTI) and transcranial magnetic stimulation (TMS) with the hand function test (HFT) to identify the type of hand function that each test (DTI and TMS) reflects. Further, we attempted to demonstrate the motor neuron organization in schizencephaly. Method. This retrospective study was conducted on 12 patients with schizencephaly. TMS was conducted in the first dorsal interosseous (FDI), biceps (BB), and deltoid muscles of the upper extremity, and contralateral MEP (cMEP) and ipsilateral MEP (iMEP) were recorded. The HFT included the grip strength, box and block (B&B), and 9-hole peg test. The schizencephalic cleft was confirmed using magnetic resonance imaging, and the corticospinal tract (CST) was identified using the color map of DTI. The symmetry indices for the peduncle and CST at pons level were calculated as the ratios of the cross-sectional area of the less-affected side and that of the more-affected side. Result. In the more-affected hemisphere TMS, no iMEP was obtained. In the less-affected hemisphere TMS, the iMEP response was detected in 9 patients and cMEP in all patients, which was similar to the pattern observed in unilateral lesion. Paretic hand grip strength was strongly correlated with the presence of iMEP ( p = 0.044 ). The symmetry index of the color map of DTI was significantly correlated with the B&B ( p = 0.008 , R 2 = 0.416 ), whereas the symmetry index of the peduncle was not correlated with all HFTs. Conclusion. In patients with schizencephaly, the iMEP response rate is correlated with the hand function related to strength, while the symmetricity of the CST by the color map of DTI is correlated with the hand function associated with dexterity. Additionally, we suggest the possible motor organization pattern of schizencephaly following interhemispheric competition.


2021 ◽  
Vol 1 (5) ◽  
pp. 263502542110405
Author(s):  
Simon J. Padanilam ◽  
Steven R. Dayton ◽  
Ryan Jarema ◽  
Michael J. Boctor ◽  
Vehniah K. Tjong

Background: Functionality testing following anterior cruciate ligament (ACL) reconstruction can benefit clinicians and patients in determining readiness for return to sport. While a component of a multifactorial decision, inability to perform well on these tests predicts increased risk of reinjury. As of 2013, only 41% of orthopaedic surgeons report using strength or functionality testing in evaluating patients for return to sport (RTS). Indications: In the intermediate to late stages of their rehabilitation program, patients may undergo these tests to determine readiness and safety to return to sport. Technique Description: The tests described in this video include the single and triple hop for distance, triple crossover hop, single and double vertical leg jump tasks, drop jump landing task, and isokinetic and isometric strength testing. Results: Clinicians who incorporate these tests into patient rehabilitation programs may reduce patient risk of ACL reinjury by 75% to 84%. The limb symmetry index (LSI) is a reliable calculated measure for these tests, with a strong reliability for the hop tests. The limb symmetry index can be calculated for each test and represents the ratio of measured performance of the involved, or post-ACL reconstruction, leg when compared against the uninvolved leg. The commonly used limb symmetry index threshold for passing each hop test is 90%. Patients who score 90% or greater on each of these tests are less likely to experience knee reinjury. Discussion/Conclusion: The ability of knee strength and functionality tests in determining RTS following ACL reconstruction has been highlighted as a tool in potentially reducing risk of knee reinjury. Other isometric and isokinetic testing can be used in addition to the described functionality tests but may not be possible in certain practices due to equipment and funding limitations. Usage of these strength and functionality tests, in conjunction with clinician evaluation, may lead to more optimal outcomes for patients and lower rates of reinjury. Psychological assessment may aid in evaluating patient readiness for return to sport. Importantly, further sport-specific testing is still recommended and will optimize patient outcomes.


Sign in / Sign up

Export Citation Format

Share Document