femoral shaft fractures
Recently Published Documents


TOTAL DOCUMENTS

1044
(FIVE YEARS 175)

H-INDEX

51
(FIVE YEARS 3)

2022 ◽  
Vol 27 (1) ◽  
Author(s):  
Henrik C. Bäcker ◽  
Mark Heyland ◽  
Chia H. Wu ◽  
Carsten Perka ◽  
Ulrich Stöckle ◽  
...  

Abstract Introduction Intramedullary (IM) fixation is the dominant treatment for pertrochanteric and femoral shaft fractures. In comparison to plate osteosynthesis (PO), IM fixation offers greater biomechanical stability and reduced non-union rates. Due to the minimally invasive nature, IM fixations are less prone to approach-associated complications, such as soft-tissue damage, bleeding or postoperative infection, but they are more prone to fat embolism. A rare but serious complication, however, is implant failure. Thus, the aim of this study was to identify possible risk factors for intramedullary fixation (IMF) and plate osteosynthesis (PO) failure. Materials and methods We searched our trauma surgery database for implant failure, intramedullary and plate osteosynthesis, after proximal—pertrochanteric, subtrochanteric—or femoral shaft fractures between 2011 and 2019. Implant failures in both the IMF and PO groups were included. Demographic data, fracture type, quality of reduction, duration between initial implantation and nail or plate failure, the use of cerclages, intraoperative microbiological samples, sonication, and, if available, histology were collected. Results A total of 24 femoral implant failures were identified: 11 IMFs and 13 POs. The average age of patients in the IM group was 68.2 ± 13.5 years and in the PO group was 65.6 ± 15.0 years, with men being affected in 63.6% and 39.5% of cases, respectively. A proximal femoral nail (PFN) anti-rotation was used in 7 patients, a PFN in one and a gamma nail in two patients. A total of 6 patients required cerclage wires for additional stability. A combined plate and intramedullary fixation was chosen in one patient. Initially, all intramedullary nails were statically locked. Failures were observed 34.1 weeks after the initial surgery on average. Risk factors for implant failure included the application of cerclage wires at the level of the fracture (n = 5, 21%), infection (n = 2, 8%), and the use of an additional sliding screw alongside the femoral neck screw (n = 3, 13%). In all patients, non-union was diagnosed radiographically and clinically after 6 months (n = 24, 100%). In the event of PO failure, the placement of screws within all screw holes, and interprosthetic fixation were recognised as the major causes of failure. Conclusion Intramedullary or plate osteosynthesis remain safe and reliable procedures in the treatment of proximal femoral fractures (pertrochanteric, subtrochanteric and femoral shaft fractures). Nevertheless, the surgeon needs to be aware of several implant-related limitations causing implant breakage. These may include the application of tension band wiring which can lead to a too rigid fixation, or placement of cerclage wires at the fracture site.


2021 ◽  
Author(s):  
Yuchang Liu ◽  
Jia-Yu Yuan ◽  
Chunfang Li ◽  
Xinjian Pei ◽  
Yazhou Li

Abstract Background: Closed reduction of pediatric femoral shaft fractures is one of the most difficult types of partial fracture reductions. Open reduction increases the harm to children. Although smaller invasive open reduction is mostly used at present, it has an impact on the microenvironment around the fracture and results in increased intraoperative bleeding, an increased risk of postoperative infection and surgical scarring, which has a great psychological impact on children. Methods: Given the above challenges, we propose another intraoperative reduction method. The technique described involves closed reduction and internal fixation for pediatric femoral shaft fractures using a new type of intraoperative fixator. Result: This technique brings hope that the success rate of closed reduction for pediatric femoral shaft fractures can reach 100%. Conclution: The method is demonstrated in a patient.


2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Christopher T. Cosgrove ◽  
Philip R. Wolinsky ◽  
Marschall B. Berkes ◽  
Christopher M. McAndrew ◽  
Dustin L. Stwalley ◽  
...  

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
David A Patch ◽  
Eli B Levitt ◽  
Nicholas A Andrews ◽  
Alex R Heatherly ◽  
Henry V Bonner ◽  
...  

Author(s):  
Alvin K. Shieh ◽  
Augustine M. Saiz Jr ◽  
Kelsey S. Hideshima ◽  
Brian M. Haus ◽  
Holly B. Leshikar

Introduction Optimal paediatric femoral shaft fracture patterns or lengths amenable to titanium elastic nail stabilization have not been well defined. The purpose of this study is to identify radiographic parameters predictive of treatment failure with flexible intramedullary nails based upon fracture morphology. Methods A retrospective review was performed of all femoral shaft fractures treated with flexible intramedullary nails over a five-year period. All patients with at least six weeks of postoperative radiographic imaging were included. Fracture characteristics included location, pattern, length, obliquity, angulation, translation and shortening. Postoperative radiographs were reviewed to determine shortening and angulation. Results There were 58 patients with 60 femoral shaft fractures stabilized with titanium nails, with 46 healing within acceptable parameters and 14 considered malunions. Six of the 14 malunions developed complications requiring early unplanned intervention. No patients in the treatment success group had a complication. Between the treatment success and failure groups, fracture pattern, location, length, obliquity, angulation, translation or shortening were not statistically different. Mean nail canal fill was significantly lower in the failure group (0.72 versus 0.81; p = 0.0146), with a receiver operating characteristic curve identifying canal fill 76% as the optimal threshold. Conclusion This is the first study to measure the length and obliquity of paediatric femoral shaft fractures and to determine their relationship to radiographic alignment after healing. None of the preoperative fracture characteristics were predictive of malalignment or shortening. We recommend the use of larger nail sizes in the treatment of paediatric femoral shaft fractures, especially if there is concern for residual instability. Level of evidence IV


Sign in / Sign up

Export Citation Format

Share Document