plasma expanders
Recently Published Documents


TOTAL DOCUMENTS

128
(FIVE YEARS 4)

H-INDEX

17
(FIVE YEARS 1)

2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Guo-Xing You ◽  
Bing-Ting Li ◽  
Zhen Wang ◽  
Quan Wang ◽  
Ying Wang ◽  
...  

Abstract Background Plasma expanders are widely used for acute normovolemic hemodilution (ANH). However, existing studies have not focused on large-volume infusion with colloidal plasma expanders, and there is a lack of studies that compare the effects of different plasma expanders. Methods The viscosity, hydrodynamic radius (Rh) and colloid osmotic pressure (COP) of plasma expanders were determined by a cone-plate viscometer, Zetasizer and cut-off membrane, respectively. Sixty male rats were randomized into five groups with Gelofusine (Gel), Hydroxyethyl Starch 200/0.5 (HES200), Hydroxyethyl Starch 130/0.4 (HES130), Hydroxyethyl Starch 40 (HES40), and Dextran40 (Dex40), with 12 rats used in each group to build the ANH model. ANH was performed by the withdrawal of blood and simultaneous infusion of plasma expanders. Acid-base, lactate, blood gas and physiological parameters were detected. Results Gel had a lower intrinsic viscosity than HES200 and HES130 (P < 0.01), but at a low shear rate in a mixture of colloids, red cells and plasma, Gel had a higher viscosity (P < 0.05 or P < 0.01, respectively). For hydroxyethyl starch plasma expanders, the COP at a certain concentration decreases from 11.1 mmHg to 6.1 mmHg with the increase of Rh from 10.7 nm to 20.2 nm. A severe ANH model, with the hematocrit of 40% of the baseline level, was established and accompanied by disturbances in acid-base, lactate and blood gas parameters. At the end of ANH and 60 min afterward, the Dex40 group showed a worse outcome in maintaining the acid-base balance and systemic oxygenation compared to the other groups. The systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) decreased significantly in all groups at the end of ANH. The DBP and MAP in the Dex40 group further decreased 60 min after the end of ANH. During the process of ANH, the Dex40 group showed a drop and recovery in SBP, DBP and MAP. The DBP and MAP in the HES200 group were significantly higher than those in the other groups at some time points (P < 0.05 or P < 0.01). Conclusion Gel had a low intrinsic viscosity but may increase the whole blood viscosity at low shear rates. Rh and COP showed a strong correlation among hydroxyethyl starch plasma expanders. Dex40 showed a worse outcome in maintaining the acid-base balance and systemic oxygenation compared to the other plasma expanders. During the process of ANH, Dex40 displayed a V-shaped recovery pattern for blood pressure, and HES200 had the advantage in sustaining the DBP and MAP at some time points.


2020 ◽  
Vol 21 (8) ◽  
pp. 427-433
Author(s):  
J. Pedro Teixeira ◽  
Lauren M. Van Sant ◽  
Nathan D. Nielsen

Author(s):  
Rosa G Simonetti ◽  
Giovanni Perricone ◽  
Dimitrinka Nikolova ◽  
Goran Bjelakovic ◽  
Christian Gluud

2019 ◽  
Vol 47 (1) ◽  
pp. 73-82
Author(s):  
Fantao Meng ◽  
Dhananjaya Kaul ◽  
Sangeetha Thangaswamy ◽  
Savita Bhutoria ◽  
Gary Gerfen ◽  
...  

2018 ◽  
pp. 357-357
Author(s):  
Mathew George ◽  
Lincy Joseph ◽  
Sujith K
Keyword(s):  

2017 ◽  
Vol 18 (8) ◽  
pp. 418-420 ◽  
Author(s):  
Robert McCahon ◽  
Jonathan Hardman
Keyword(s):  

2017 ◽  
Vol 7 (1) ◽  
Author(s):  
Elena I. Sinauridze ◽  
Alexander S. Gorbatenko ◽  
Elena A. Seregina ◽  
Elena N. Lipets ◽  
Fazoil I. Ataullakhanov

2016 ◽  
Vol 6 (6) ◽  
pp. 511-521
Author(s):  
R. Guerciolini ◽  
F. Merante ◽  
P. Gresele ◽  
S. Grasselli ◽  
L. Susani ◽  
...  

2016 ◽  
Vol 35 ◽  
pp. 75-83 ◽  
Author(s):  
Claudia Moeller ◽  
Carolin Fleischmann ◽  
Daniel Thomas-Rueddel ◽  
Vlasislav Vlasakov ◽  
Bram Rochwerg ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document