cadmium detection
Recently Published Documents


TOTAL DOCUMENTS

44
(FIVE YEARS 20)

H-INDEX

12
(FIVE YEARS 3)

Sensors ◽  
2021 ◽  
Vol 22 (1) ◽  
pp. 105
Author(s):  
Selma Rabai ◽  
Ahlem Teniou ◽  
Gaëlle Catanante ◽  
Messaoud Benounis ◽  
Jean-Louis Marty ◽  
...  

Cadmium (Cd2+) is one of the most toxic heavy metals causing serious health problems; thus, designing accurate analytical methods for monitoring such pollutants is highly urgent. Herein, we report a label-free electrochemical aptasensor for cadmium detection in water. For this, a nanocomposite combining the advantages of gold nanoparticles (AuNPs), carbon nanotubes (CNTs) and chitosan (Cs) was constructed and used as immobilization support for the cadmium aptamer. First, the surface of a glassy carbon electrode (GCE) was modified with CNTs-CS. Then, AuNPs were deposited on CNTs-CS/GCE using chrono-amperometry. Finally, the immobilization of the amino-modified Cd-aptamer was achieved via glutaraldehyde cross-linking. The different synthesis steps of the AuNPs/CNTs/CS nano assembly were characterized by cyclic voltammetry (CV). Electrochemical impedance spectroscopy (EIS) was employed for cadmium determination. The proposed biosensor exhibited excellent performances for cadmium detection at a low applied potential (−0.5 V) with a high sensitivity (1.2 KΩ·M−1), a detection limit of 0.02 pM and a wide linear range (10−13–10−4 M). Moreover, the aptasensor showed a good selectivity against the interfering ions: Pb2+; Hg2+ and Zn2+. Our electrochemical biosensor provides a simple and sensitive approach for Cd2+ detection in aqueous solutions, with promising applications in the monitoring of trace amounts of heavy metals in real samples.


2021 ◽  
Author(s):  
Shulin Hu ◽  
Jun Yang ◽  
Anqi Liao ◽  
Ying Lin ◽  
Shuli Liang

Abstract Cadmium contamination is a severe threat to the environment and food safety. Thus, there is an urgent need to develop highly sensitive and selective cadmium detection tools. The engineered fluorescent indicator is a powerful tool for the rapid detection of inorganic cadmium in the environment. In this study, the development of yellow fluorescent indicators of cadmium chloride by inserting a fluorescent protein at different positions of the high cadmium-specific repressor and optimizing the flexible linker between the connection points is reported. These indicators provide a fast, sensitive, specific, high dynamic range, and real-time readout of cadmium ion dynamics in solution. Under optimal conditions, the fluorescent indicators N0C0/N1C1 showed a linear response to cadmium concentration within the range from 10/30 to 50/100 nM and with a detection limit of 10/33 nM. Escherichia coli cells containing the indicator were used to further study the response of cadmium ion concentration in living cells. E. coli N1C1 could respond to different concentrations of cadmium ions. This study provides a rapid and straightforward method for cadmium ion detection in vitro and the potential for biological imaging.


Author(s):  
Guangbao Zhang ◽  
Shuting Hu ◽  
Xiaoqiang Jia

Although many whole-cell biosensors (WCBs) for the detection of Cd2+ have been developed over the years, most lack sensitivity and specificity. In this paper, we developed a Cd2+ WCB with a negative feedback amplifier in P. putida KT2440. Based on the slope of the linear detection curve as a measure of sensitivity, WCB with negative feedback amplifier greatly increased the output signal of the reporter mCherry, resulting in 33% greater sensitivity than in an equivalent WCB without the negative feedback circuit. Moreover, WCB with negative feedback amplifier exhibited increased Cd2+ tolerance and a lower detection limit of 0.1 nM, a remarkable 400-fold improvement compared to the WCB without the negative feedback circuit, which is significantly below the World Health Organization standard of 27 nM (0.003 mg/L) for cadmium in drinking water. Due to the superior amplification of the output signal, WCB with negative feedback amplifier can provide a detectable signal in a much shorter time, and a fast response is highly preferable for real field applications. In addition, the WCB with negative feedback amplifier showed an unusually high specificity for Cd2+ compared to other metal ions, giving signals with other metals that were between 17.6 and 41.4 times weaker than with Cd2+. In summary, the negative feedback amplifier WCB designed in this work meets the requirements of Cd2+ detection with very high sensitivity and specificity, which also demonstrates that genetic negative feedback amplifiers are excellent tools for improving the performance of WCBs.


2021 ◽  
Vol 9 (2) ◽  
pp. 111-117
Author(s):  
Budi Riza Putra ◽  
Manggar Arum Aristri ◽  
Eti Rohaeti ◽  
Wulan Tri Wahyuni

Cadmium is a toxic pollutant that is harmful to the environment and humans. The purpose of this research was to develop a method for cadmium(II) detection using differential pulse anodic stripping voltammetry (DPASV) using a glassy carbon electrode. The developed method was then applied for cadmium detection in the vegetable samples which is water spinach. The developed method was optimized in several parameters such as potential window, deposition potential, deposition time, and scan rate. The developed method for cadmium(II) detection was also investigated in its analytical performance includes linearity, precision, detection limit, and quantitation limit. The optimum conditions for cadmium(II) detection in 0.1 M KCl using DPASV technique obtained such as potential window from -1200 to -100 mV, deposition potential of -1100 mV (vs Ag/AgCl), and deposition time of 360 s. It was obtained good linearity for cadmium(II) detection using the DPASV technique with an R2 of 0.996. The precision was expressed as %SBR with 0.66%. The detection and quantitation limits for cadmium(II) detection were 0.4206 µM~0.0771 ppm and 0.5525 µM~0.1013 ppm, respectively. The developed method was then applied for cadmium(II) measurement in the water spinach sample and the obtained cadmium(II) concentration in water spinach was 0.2399 mg/Kg.


Talanta ◽  
2021 ◽  
Vol 232 ◽  
pp. 122409
Author(s):  
Bin Lai ◽  
Haitao Wang ◽  
Wentao Su ◽  
Zhouping Wang ◽  
Bei-Wei Zhu ◽  
...  

2021 ◽  
Vol 19 (7) ◽  
pp. 187-195
Author(s):  
Mohammed S. Sada ◽  
Bushra R. Mahdi ◽  
Hashim Ali ◽  
Nahla A. Aljbar ◽  
Mahdi A. Mohammed

In this work, fabrication of Localized Surface Plasmon Resonance based fiber optic sensing probe for cadmium detection in an aqueous solution is reported. Multimode fiber-photonic crystal fiber-multimode fiber structure coated with gold nanoparticles make up this probe. The proposed sensor's sensitivity is 1.564 nm/ppm. Furthermore, the sensor is small in size, immune to electromagnetic interference, making it ideal for a wide range of harsh environments and real-time measurement.


2021 ◽  
Vol 21 (8) ◽  
pp. 9626-9633
Author(s):  
Sandra Cristina Ballen ◽  
Greice M. Ostrowski ◽  
Juliana Steffens ◽  
Clarice Steffens

2021 ◽  
Vol 33 (1) ◽  
Author(s):  
Wei Wang ◽  
Wenwen Kong ◽  
Tingting Shen ◽  
Zun Man ◽  
Wenjing Zhu ◽  
...  

Abstract Background Excessive cadmium can damage cell structure, inhibit enzyme activity, and affect metabolic process, thus, leading to decline of rice yield and quality. Root is an important organ of crops, the detection of cadmium in root is essential for limitation of cadmium in rice grains. Results In this study, laser-induced breakdown spectroscopy (LIBS) was applied for cadmium quantitative analysis. Pretreatment methods, including median absolute deviation, wavelet transform, area normalization, were used to improve spectral stability. Scanning electron microscope and energy-dispersive X-ray spectrometer (SEM/EDS) was first used to analyze ablation pit surface characteristics and the results showed significant positive correlation with spectral lines of Cd II 214.44, Cd II 226.50 and Cd I 228.80 nm. Univariable models of spectral lines showed that three Cd spectral lines have good prediction for cadmium. Fitting methods including linear, logarithmic, and polynomial were used to propose characteristic input variables, and univariable models based on variable of polynomial fitting of I214.44 nm have achieved the best effect (Rp = 0.9821 and RMSEP = 31.1 mg/kg). Besides, partial least squares regression (PLSR), least squares support vector machine (LS-SVM) and extreme learning machine (ELM) were used for multivariate analysis. Compared with univariate analysis, ELM model based on the full spectrum (Rp = 0.9896 and RMSEP = 26.0 mg/kg) had more advantages for cadmium detection. Conclusion Compared with traditional methods (150 min), the quantitative detection method based on LIBS technology (less than 5 min) greatly reduces the detection time of heavy metals. The results showed that LIBS has proved to be a reliable method for quantitative detection of cadmium in rice roots. The research can provide theoretical support for timely detection of heavy metals in crop and food production.


Sign in / Sign up

Export Citation Format

Share Document