fidelity scale
Recently Published Documents


TOTAL DOCUMENTS

62
(FIVE YEARS 25)

H-INDEX

12
(FIVE YEARS 3)

2021 ◽  
pp. 003435522110432
Author(s):  
Tim Riesen ◽  
Stephen Hall ◽  
Beth Keeton ◽  
Aubrey Snyder

The discovery fidelity scale (DFS) is a 15-item instrument used to determine fidelity to systems and services level discovery best practices. Fidelity scale development is typically guided by an iterative, three-part process that includes identifying and specifying the fidelity structure and content, measuring and confirming the content, and assessing the internal consistency and reliability of the scale. This study is the initiation of the third step of the fidelity process to determine if items on the DFS accurately and reliably measure the discovery construct (internal consistency). The study also examined outcomes for individuals engaged in the discovery process. The results of the study suggest that both the systems and services components appear to measure their respective constructs and the overall discovery construct appears to have acceptable internal consistency.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Lars Hestmark ◽  
Kristin Sverdvik Heiervang ◽  
Reidar Pedersen ◽  
Kristiane Myckland Hansson ◽  
Torleif Ruud ◽  
...  

Abstract Background Family involvement for persons with psychotic disorders is supported by scientific evidence, as well as legal and ethical considerations, and recommended in clinical practice guidelines. This article reports a cross-sectional measurement of the level of implementation of such guidelines in fifteen community mental health centre units in Norway, and presents a novel fidelity scale to measure basic family involvement and support. The aim was to investigate current family involvement practices comprehensively, as a basis for targeted quality improvement. Methods We employed three fidelity scales, with 12–14 items, to measure family involvement practices. Items were scored from 1 to 5, where 1 equals no implementation and 5 equals full implementation. Data was analysed using descriptive statistics, a non-parametric test, and calculation of interrater reliability for the scales. Results The mean score was 2.33 on the fidelity scale measuring basic family involvement and support. Among patients with psychotic disorders, only 4% had received family psychoeducation. On the family psychoeducation fidelity assessment scale, measuring practice and content, the mean score was 2.78. Among the eight units who offered family psychoeducation, it was 4.34. On the general organizational index scale, measuring the organisation and implementation of family psychoeducation, the mean score was 1.78. Among the units who offered family psychoeducation, it was 2.46. As a measure of interrater reliability, the intra-class correlation coefficient was 0.99 for the basic family involvement and support scale, 0.93 for the family psychoeducation fidelity assessment scale and 0.96 for the general organizational index scale. Conclusions The implementation level of the national guidelines on family involvement for persons with psychotic disorders was generally poor. The quality of family psychoeducation was high, but few patients had received this evidence-based treatment. Our novel fidelity scale shows promising psychometric properties and may prove a useful tool to improve the quality of health services. There is a need to increase the implementation of family involvement practices in Norway, to reach a larger percentage of patients and relatives. Trial registration ClinicalTrials.gov Identifier NCT03869177. Registered 11.03.19.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
N. Hasselberg ◽  
K. H. Holgersen ◽  
G. M. Uverud ◽  
J. Siqveland ◽  
B. Lloyd-Evans ◽  
...  

Abstract Background Crisis resolution teams (CRTs) are specialized multidisciplinary teams intended to provide assessment and short-term outpatient or home treatment as an alternative to hospital admission for people experiencing a mental health crisis. In Norway, CRTs have been established within mental health services throughout the country, but their fidelity to an evidence-based model for CRTs has been unknown. Methods We assessed fidelity to the evidence-based CRT model for 28 CRTs, using the CORE Crisis Resolution Team Fidelity Scale Version 2, a tool developed and first applied in the UK to measure adherence to a model of optimal CRT practice. The assessments were completed by evaluation teams based on written information, interviews, and review of patient records during a one-day visit with each CRT. Results The fidelity scale was applicable for assessing fidelity of Norwegian CRTs to the CRT model. On a scale 1 to 5, the mean fidelity score was low (2.75) and with a moderate variation of fidelity across the teams. The CRTs had highest scores on the content and delivery of care subscale, and lowest on the location and timing of care subscale. Scores were high on items measuring comprehensive assessment, psychological interventions, visit length, service users’ choice of location, and of type of support. However, scores were low on opening hours, gatekeeping acute psychiatric beds, facilitating early hospital discharge, intensity of contact, providing medication, and providing practical support. Conclusions The CORE CRT Fidelity Scale was applicable and relevant to assessment of Norwegian CRTs and may be used to guide further development in clinical practice and research. Lower fidelity and differences in fidelity patterns compared to the UK teams may indicate that Norwegian teams are more focused on early interventions to a broader patient group and less on avoiding acute inpatient admissions for patients with severe mental illness.


Author(s):  
Sosei Yamaguchi ◽  
Sayaka Sato ◽  
Yasutaka Ojio ◽  
Takuma Shiozawa ◽  
Asami Matsunaga ◽  
...  

2020 ◽  
Vol 71 (12) ◽  
pp. 1245-1251
Author(s):  
Donald Addington ◽  
Valerie Noel ◽  
Matthew Landers ◽  
Gary R. Bond

2020 ◽  
Vol 142 (12) ◽  
Author(s):  
Pawel J. Przytarski ◽  
Andrew P. S. Wheeler

Abstract In this paper, we study the effect of rotor-stator axial gap on midspan compressor loss using high-fidelity scale-resolving simulations. For this purpose, we mimic the multi-stage environment using a new numerical method that recycles wake unsteadiness from a single blade passage back into the inlet of the computational domain. As a result, a type of repeating-passage simulation is obtained such as observed by an embedded blade-row. We find that freestream turbulence levels rise significantly as the size of the rotor-stator axial gap is reduced. This is because of the effect of axial gap on turbulence production, which becomes amplified at smaller axial gaps and drives increases in dissipation and loss. This effect is found to raise loss by between 5.5% and 9.5% over the range of conditions tested here. This effect significantly outweighs the beneficial effects of wake recovery on loss.


2020 ◽  
Vol 1 (1) ◽  
Author(s):  
Tonje Fyhn ◽  
Kari Ludvigsen ◽  
Silje E. Reme ◽  
Frederieke Schaafsma

Abstract Background Individual Placement and Support (IPS) is an evidence-based work rehabilitation program helping people with moderate to severe mental illness to obtain ordinary employment. Although IPS has proven superior to other work rehabilitation programs, in many studies, the majority of the participants remain unemployed. Structured process evaluations of IPS that use mixed methods are scarce, although they could identify implementation aspects that may enhance its effect. The aim of the current study is to assess reach, fidelity, and identify barriers and facilitators to implement IPS. Methods The process evaluation was conducted alongside a randomized controlled trial including six IPS centers, comparing IPS with treatment as usual in a population of patients in treatment for moderate to severe mental illness. Mixed methods were used in the process evaluation, including focus group interviews with service providers, individual interviews and survey data from participants, and fidelity reviews using the validated IPS Fidelity Scale. Results The intervention reached the intended target group. All centers reached fair to good fidelity according to the IPS Fidelity Scale within the project period (range 97–109, SD 8.1) (see Table 5). Certain fidelity items indicated implementation issues related to employer contact, community-based services, and integration with health services. Survey data showed that less than half of the participants regarded their illness as a barrier for participating in IPS and that freedom of disclosure was important. Participant interviews gave further insight into the role of the IPS specialist, emphasizing their availability and consistent job focus. Conclusions Indications of implementation challenges across centers during the first year suggest special attention should be given to these aspects in an early phase to ensure higher fidelity from the start and thus enhance the effectiveness of IPS. The IPS specialist played an important role for participants and was described as positive, pushing in a positive way, and encouraging. More knowledge on the characteristics of successful IPS specialists could further enhance the effectiveness of the intervention. Trial registration The study was registered on clinicaltrials.gov prior to the inclusion period (reg.no: NCT01964092, registered 17/07/2013).


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
A. L. Van Melle ◽  
E. O. Noorthoorn ◽  
G. A. M. Widdershoven ◽  
C. L. Mulder ◽  
Y. Voskes

Abstract Background A new inpatient care model has been developed in the Netherlands: High and Intensive Care (HIC). The purpose of HIC is to improve quality of inpatient mental healthcare and to reduce coercion. Methods In 2014, audits were held at 32 closed acute admission wards for adult patients throughout the Netherlands. The audits were done by trained auditors, who were professionals of the participating institutes, using the HIC monitor, a model fidelity scale to assess implementation of the HIC model. The HIC model fidelity scale (67 items) encompasses 11 domains including for example team structure, team processes, diagnostics and treatment, and building environment. Data on seclusion and forced medication was collected using the Argus rating scale. The association between HIC monitor scores and the use of seclusion and forced medication was analyzed, corrected for patient characteristics. Results Results showed that wards having a relatively high HIC monitor total score, indicating a high level of implementation of the model as compared to wards scoring lower on the monitor, had lower seclusion hours per admission hours (2.58 versus 4.20) and less forced medication events per admission days (0.0162 versus 0.0207). The HIC model fidelity scores explained 27% of the variance in seclusion rates (p < 0.001). Adding patient characteristics to HIC items in the regression model showed an increase of the explained variance to 40%. Conclusions This study showed that higher HIC model fidelity was associated with less seclusion and less forced medication at acute closed psychiatric wards in the Netherlands.


Sign in / Sign up

Export Citation Format

Share Document