thermal tissue damage
Recently Published Documents


TOTAL DOCUMENTS

26
(FIVE YEARS 7)

H-INDEX

7
(FIVE YEARS 2)

Author(s):  
Simon Hein ◽  
Ralf Petzold ◽  
Rodrigo Suarez-Ibarrola ◽  
Martin Schoenthaler ◽  
Christian Gratzke ◽  
...  

Abstract Purpose To objectively determine whether there is potential thermal tissue damage during Tm:YAG laser-based LUTS treatment. Methods Our experimental model was comprised of a prostatic resection trainer placed in a 37 °C water bath. In a hollowed-out central area simulating the urethral lumen, we placed a RigiFib 800 fibre, irrigation inflow regulated with a digital pump, and a type K thermocouple. A second thermocouple was inserted 0.5/1 cm adjacently and protected with an aluminum barrier to prevent it from urethral fluid. We investigated continuous and intermittent 120 W and 80 W laser application with various irrigation rates in eight measurement sessions lasting up to 14 min. Thermal measurements were recorded continuously and in real-time using MatLab. All experiments were repeated five times to balance out variations. Results Continuous laser application at 120 W and 125 ml/min caused a urethral ∆T of ~ 15 K and a parenchymal temperature increase of up to 7 K. With 50 ml/min irrigation, a urethral and parenchymal ∆T of 30 K and 15 K were reached, respectively. Subsequently and in absence of laser application, prostatic parenchyma needed over 16 min to reach baseline body temperature. At 80 W lower temperature increases were reached compared to similar irrigation but higher power. Conclusions We showed that potentially harming temperatures can be reached, especially during high laser power and low irrigation. The heat generation can also be conveyed to the prostate parenchyma and deeper structures, potentially affecting the neurovascular bundles. Further clinical studies with intracorporal temperature measurement are necessary to further investigate this potentially harming surgical adverse effect.


2020 ◽  
Vol 98 (11) ◽  
Author(s):  
Abbie V Viscardi ◽  
Charley A Cull ◽  
Michael D Kleinhenz ◽  
Shawnee Montgomery ◽  
Andrew Curtis ◽  
...  

Abstract CO2 surgical lasers are widely used for procedures in veterinary and human medicine. There is evidence to suggest surgery using a CO2 laser reduces pain and swelling and improves healing time compared with surgery with a scalpel. Millions of piglets in North America are surgically castrated each year using a scalpel. Therefore, piglet welfare may be improved by making refinements to the surgical procedure. The objectives of this preliminary study were to determine the ability of a CO2 surgical laser to (1) reduce pain and (2) improve wound healing of piglets undergoing surgical castration. Two-day-old male Yorkshire × Landrace piglets were used and randomly assigned to 1 of 3 treatments (n = 10 piglets/treatment group): surgical castration with the CO2 laser, surgical castration with a scalpel, or sham (uncastrated control). Piglets were video recorded in their pens for 1 hr preprocedure and from 0 to 2, 6 to 8, and at 24 hr postprocedure for behavior scoring. Surgical site images were collected at baseline, 0, 8, 24, 48, 72, 96, 120, 144, and 168 hr postcastration for wound healing assessment. Infrared thermography images of the surgical site were also taken at baseline, 0, 0.5, 8, and 24 hr postprocedure to assess inflammation. Finally, blood was collected from each piglet at baseline and 0.5 hr postcastration to assess cortisol levels, prostaglandin E metabolite and pig-major acute phase protein concentration. Laser-castrated piglets displayed more pain behaviors across the observation period than scalpel-castrated piglets (P = 0.05). Laser-castrated piglets also displayed significantly more agonistic behavior than both scalpel-castrated piglets (P = 0.005) and sham piglets (P = 0.036); yet, laser-castrated piglets had significantly lower temperatures at the site of incision compared with scalpel-castrated piglets (P = 0.0211). There was no significant difference in wound healing or any of the blood parameters assessed between laser-castrated and scalpel-castrated piglets. There was evidence of thermal tissue damage on the scrotum of piglets that were castrated using the CO2 laser. This may have resulted in the unremarkable healing time and the increased pain behavior observed in this study. The surgical laser technique should be refined before conclusions can be made regarding the utility of a CO2 laser for piglet castration.


Materials ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1167
Author(s):  
Bogusława Żywicka ◽  
Zbigniew Rybak ◽  
Maciej Janeczek ◽  
Albert Czerski ◽  
Jolanta Bujok ◽  
...  

Partial and total splenectomies are associated with a high risk of substantial blood loss. Lasers operating at wavelengths strongly absorbed by water have the potential to improve hemostasis and cut while providing a narrow zone of thermal damage. The aim of this study is to compare a thulium-doped fiber laser (TDFL) emitting a wavelength of 1940 nm and a diode laser (DL) operating at 1470 nm for spleen surgery in a pig model. A partial splenectomy and spleen incisions were made in 12 animals using the two laser devices. The hemostasis was evaluated visually during surgeries. Post-mortem and histopathological evaluations were done on days 0, 7, and 14 following surgery. Neither TDFL nor DL caused bleeding on day 0 or delayed bleeding. On day 14, pale streaks at the site of incision were slightly wider after cutting with DL than with TDFL. Histological analysis revealed a carbonized zone with exudation and a deeper zone of thermal tissue damage on day 0. The width of the thermal changes was 655.26 ± 107.70 μm for TDFL and 1413.37 ± 111.85 μm for DL. On day 7, a proliferation of fibroblasts and splenocytes was visible, as well as a formation of multinucleated giant cells adjacent to the residues of carbonization. The zone of thermal damage was broader for DL (1157.5 ± 262.77 μm) than for TDFL (682.22 ± 116.58 μm). On day 14, cutting sites were filled with connective and granulation tissues with the residues of carbonization. The zone of thermal damage was narrower for TDFL (761.65 ± 34.3 μm) than for DL (1609.82 ± 202.22 μm). Thus, both lasers are efficient in spleen surgery, providing good hemostasis. However, TDFL produces a narrower zone of thermal damage, which suggests its better efficiency for spleen surgery, especially when performing more precise procedures.


Cancers ◽  
2019 ◽  
Vol 11 (11) ◽  
pp. 1718 ◽  
Author(s):  
Stefano Lafranceschina ◽  
Oronzo Brunetti ◽  
Antonella Delvecchio ◽  
Maria Conticchio ◽  
Michele Ammendola ◽  
...  

Background: Ablative techniques provide in patients with locally advanced pancreatic cancer (LAPC) symptomatic relief, survival benefit and potential downsizing. Irreversible Electroporation (IRE) represents potentially an ideal solution as no thermal tissue damage occurs. The purpose of this review is to present an overview on safety, feasibility, oncological results, survival and quality of life improvement obtained by IRE. Methods: A systematic search was performed in PubMed, regarding the use of IRE on PC in humans for studies published in English up to March 2019. Results: 15 original studies embodying 691 patients with unresectable LAPC who underwent IRE were included. As emerged, IRE works better on tumour sizes between 3–4 cm. Oncological results are promising: median OS from diagnosis or treatment up to 27 months. Two groups investigated borderline resectable tumours treated with IRE before resection with margin attenuation, whereas IRE has proved to be effective in pain control. Conclusions: Electroporation is bringing new hopes in LAPC management. The first aim of IRE is to offer a palliative treatment. Further efforts are needed for patient selection, as well as the use of IRE for ‘margin accentuation’ during surgical resection. Even if promising, IRE needs to be validated in large, randomized, prospective series.


2015 ◽  
Vol 15 (3) ◽  
pp. 321-327 ◽  
Author(s):  
Omar Choudhri ◽  
Robert M. Lober ◽  
Joaquin Camara-Quintana ◽  
Kristen W. Yeom ◽  
Raphael Guzman ◽  
...  

OBJECT The authors describe the application of a flexible CO2 laser for corpus callosotomy in children with epilepsy. METHODS This retrospective case series reviews all cases in which pediatric patients underwent a corpus callosotomy performed using the CO2 OmniGuide laser between May 2005 and October 2012. Data were collected from 8 corpus callosotomy procedures in 6 pediatric patients presenting with medically refractory epilepsy marked by drop attacks. RESULTS Complete corpus callosotomies were performed in 6 patients (3 boys, 3 girls; ages 5–14 years). In 4 patients the complete callosotomy occurred as a single procedure, and in 2 patients an anterior two-thirds callosotomy was performed first. These 2 patients subsequently required a complete callosotomy due to inadequate control of their drop attacks. In all cases there was clean lesioning of the tract with preservation of the ependymal plane and less inadvertent thermal tissue damage due to low penetration of the laser through cerebrospinal fluid. All patients had resolution or improvement of drop attacks after surgery. No complications were encountered, and imaging demonstrated a clean sectioning of callosal fibers with preservation of normal ventricular anatomy. CONCLUSIONS These cases illustrate the use of this device in completing corpus callosotomy in pediatric patients. The low-profile laser fiber tip was well suited for working in the depths of the interhemispheric fissure with minimal brain retraction. The flexible CO2 laser allows a precise callosal lesioning through an interhemispheric approach and is a useful adjunct to be employed in these cases.


Sign in / Sign up

Export Citation Format

Share Document