fluent software
Recently Published Documents


TOTAL DOCUMENTS

560
(FIVE YEARS 156)

H-INDEX

8
(FIVE YEARS 3)

2022 ◽  
Vol 16 (2) ◽  
pp. 29-40
Author(s):  
S. A. Akinin ◽  
A. V. Starov

The results of computational and experimental studies of a model of a hypersonic convergent air intake are presented. Experimental studies were carried out in a hot-shot wind tunnel IT-302M SB RAS at a Mach number M = 5.7 and an angle of attack α = 4 °. Numerical modeling was carried out in a three-dimensional setting in the ANSYS Fluent software package. The calculations were carried out in 4 versions using different turbulence models: k-ɛ standard, RNG k-ɛ, k-ɷ standard and k-ɷ SST. The features of the flow structure are established. The pressure distributions on the compression surfaces and in the air intake channel are obtained. The separated flow at the entrance of the inner channel was studied. It was found that the use of various turbulence models has a significant effect on the size and position of separation. The best agreement between the calculated and experimental data on the level of static pressure was shown by the variant with the k-ɛ standard turbulence model.


In this work, bifurcation characteristics of unsteady, viscous, Newtonian laminar flow in two-dimensional sudden expansion and sudden contraction-expansion channels have been studied for different values of expansion ratio. The governing equations have been solved using finite volume method and FLUENT software has been employed to visualize the simulation results. Three different mesh studies have been performed to calculate critical Reynolds number (Recr) for different types of bifurcation phenomena. It is found that Recr decreases with the increase in expansion ratio (ER).


2022 ◽  
Vol 355 ◽  
pp. 02013
Author(s):  
Jiahu Li ◽  
Zhi Wang ◽  
Chi Ma

China began entering the 14th Five-Year Plan period in 2021. With the proposed carbon-neutral long-term goal, the strategic position of clean energy is becoming increasingly prominent. using biomass power generation is one of the main application ways. In order to study the mixed combustion process of coal and biomass, this paper takes 300MW lignite boiler as the research object and uses Fluent software to explore the influence of biomass types and the location of biomass nozzle on the mixed combustion, and obtains the corresponding temperature field, flue gas component field and the distribution of pollutant NO. The results showed that when the biomass particles were sprayed into a fixed position with a certain proportion, the NO emission of wheat, corn and cotton straw was reduced, and the effect of wheat straw was the most obvious. When a certain proportion of wheat straw and coal are co-fired, the higher the biomass nozzle position, the higher the peak temperature in the main combustion zone, and the better the emission reduction effect of NO.


2022 ◽  
Vol 355 ◽  
pp. 01001
Author(s):  
Pan Jin ◽  
Jin Feng

Suppose that curved compression surface of inlet consists of segments. Two curved surfaces formed by equal compression angles of the micro-element segments and a slight increase in the compression angle of the micro-element segments are designed respectively. The numerical simulation method is used to compare the performance of two curved surfaces with the reference three-wedge compression surface. Select NASA classic test data, in order to determine the turbulence model and calculation method chosen by the numerical simulation Fluent software. The results show: the configuration of the segment compression angle deeply affects compression efficiency of the curved surface compression system. Pressure gradient distribution on the compression surface with constant compression angles segments is nearly constant along the incoming flow direction, and the curved compression surface easily resist the separation of the boundary layer compared to three-wedges compression surface. The approximate calculation method of the bending shock profile is given.


Processes ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 53
Author(s):  
Zdzislaw Salamonowicz ◽  
Malgorzata Majder-Lopatka ◽  
Anna Dmochowska ◽  
Aleksandra Piechota-Polanczyk ◽  
Andrzej Polanczyk

Contamination of toxic and odorous gases emitted from stacks in buildings located in an urban environment are potential health hazards to citizens. A simulation using the computational fluid dynamic technique may provide detailed data on the flammable region and spatial dispersion of released gases. Concentrations or emissions associated with garage sources and garage-to-house migration rates are needed to estimate potential exposures and risk levels. Therefore, the aim of the study was to use an original mathematical model to predict the most accurate locations for LPG sensors in an underground garage for vehicles powered with LPG. First, the three-dimensional geometry of an underground garage under a multi-family building was reconstructed. Next, two types of ventilation, jet and duct, were considered, and different sources of LPG leakage were assumed. Then, the Ansys Fluent software was applied as a solver, and the same initial value of released LPG (5 kg) was assumed. As a simplification, and to avoid the simulation of choked outflow, the emission from a large area was adopted. The results showed stagnation areas for duct ventilation in which gas remained for both the jet and duct ventilation. Moreover, it was observed that the analyzed gas would gather in the depressions of the ground in the underground garage, for example in drain grates, which may create a hazardous zone for the users of the facility. Additionally, it was observed that for jet ventilation, turbulence appearance sometimes generated differentiated gas in an undesirable direction. The simulation also showed that for blowing ventilation around the garage, and for higher LPG leakage, a higher cloud of gas that increased probability of ignition and LPG explosion was formed. Meanwhile, for jet ventilation, a very low concentration of LPG in the garage was noticed. After 35 s, LPG concentration was lower than the upper explosive limit. Therefore, during the LPG leakage in an underground garage, jet ventilation was more efficient in decreasing LPG gas to the non-explosive values.


2021 ◽  
Vol 13 (2) ◽  
pp. 51-57
Author(s):  
Sandip Saha

The aim of this study is to investigate the heat transfer characteristics of turbulent airflow phenomena in a rectangular micro-channel in presence of two plane shaped (type-1) and diamond shaped (type-2) baffles which will help to develop various heat exchanger models. Finite volume method has been used to solve the governing equations and the FLUENT software has been employed to visualize the simulation results. For both the baffles, the profile of flow structure, normalized velocity profile, normalized friction factor and average Nusselt number have been investigated with the variations of Reynolds number ranges between [10,000-50,000]. In terms of fluid flow and heat transfer phenomena, it has been found that in the presence of diamond shaped baffles (type-2) are more convenient than plane shaped baffles.


Lithosphere ◽  
2021 ◽  
Vol 2021 (Special 4) ◽  
Author(s):  
Zhe Li ◽  
Fangtian Wang ◽  
Shuai Ren ◽  
Guannan Liu

Abstract The prevention of gas overrun in the panel is one of the key issues on green mining. In this paper, a physical goaf model was established based on the geological production conditions of a coal seam in a coal mine in Henan Province, and the combined drainage technology by burying and spilling pipeline in the upper corner was proposed. The Fluent software was used to simulate the changes of gas mass fraction and flow field distribution when the gas is extracted from the goaf without the gas pipeline, with a single buried pipeline, and with the combination of buried and spilled pipelines. Analysis and simulation showed that in the absence of drainage pipelines, the gas concentrations in both the return airway and the upper corner are up to 1.2%, which failed to meet the gas prevention and control standard on the mine. In the case of gas drainage with a single buried pipeline, the average gas concentration in the return airway was 0.7%, and only the gas concentration in the upper corner was up to 1.1%, which failed to meet the gas control standards on the mine’s panel. However, the maximum gas concentration in the combined drainage was reduced from 1.1% to 0.6%, which indicates that the technology can greatly reduce gas concentration, but there is still a gap from the mine’s gas control standard. Therefore, the impacts of the lengths of pipelines buried in different goafs on the gas drainage effect in the goaf were studied, and it was concluded that the reasonable length of pipelines buried in the goaf under the geological conditions was 20 m. This technology not only solves the problem of gas overrun in the panel but also realizes the utilization of gas resources in the goaf. The research results are of guiding significance for pipeline laying and the drainage technology in the upper corners on the U-shaped ventilation panel.


2021 ◽  
Vol 10 (24) ◽  
pp. 5752
Author(s):  
Michał Kozłowski ◽  
Krzysztof Wojtas ◽  
Wojciech Orciuch ◽  
Marek Jędrzejek ◽  
Grzegorz Smolka ◽  
...  

Paravalvular leaks (PVLs) may lead to hemolysis. In vitro shear stress forces above 300 Pa cause erythrocyte destruction. PVL channel dimensions may determine magnitude of shear stress forces that affect erythrocytes; however, this has not been tested. It remains unclear how different properties of PVL channels contribute to presence of hemolysis. A model of a left ventricle was created based on data from computer tomography with Slicer software PVLs of various shapes and sizes were introduced. Blood flow was simulated using ANSYS Fluent software. The following variables were examined: wall shear stress, shear stress in fluid, volume of PVL channel with shear stress exceeding 300 Pa, and duration of exposure of erythrocytes to shear stress values above 300 Pa. In all models, shear stress forces exceeded 300 Pa. Shear stress increased with blood flow rates and cross-sectional areas of any PVL. There was no linear relationship between cross-sectional area of a PVL and volume of a PVL channel with shear stress > 300 Pa. Blood flow through mitral PVLs is associated with shear stress above 300 Pa. Cross-sectional area of a PVL does not correlate with volume of a PVL channel with shear stress > 300 Pa and duration of exposure of erythrocytes to shear stress > 300 Pa.


Sign in / Sign up

Export Citation Format

Share Document