instructions for use
Recently Published Documents


TOTAL DOCUMENTS

354
(FIVE YEARS 145)

H-INDEX

19
(FIVE YEARS 4)

2022 ◽  
Author(s):  
Danielle K. Bayoro ◽  
Daniel Hoolihan ◽  
Michael J Pedro ◽  
Edward A. Rose ◽  
Andreas D. Waldmann

Abstract Current guidelines recommend the use of an intravenous fluid warmer to prevent perioperative hypothermia. Among the various methods of warming intravenous fluids, contact warmers are among the most effective and accurate, particularly in clinical conditions requiring rapid infusions of refrigerated blood or fluids. Contact warmers put the infusate in direct contact with a heating block. Some fluid warmers use heating blocks manufactured from aluminium. Several recent publications, however, have shown that uncoated aluminium blocks can leach potentially toxic amounts of aluminium into the body. In this review we performed a systematic literature review on aluminium leaching with contact fluid warmers and describe what manufacturer and competent authorities did in the past years to ensure patient safety. The search resulted in five articles describing the aluminium leaching. Four different devices (Level 1 Fluid Warmer from Smiths Medical, ThermaCor from Smisson-Cartledge Biomedical, Recirculator 8.0 from Eight Medical International BV, enFlow from Vyaire) were shown to leach high levels of aluminium when heating certain intravenous fluids. One manufacturer (Vyaire) voluntarily removed their product from the market, while three manufacturers (Eight Medical International BV, Smisson-Cartledge Biomedical, and Smiths Medical) revised the instructions for use for the affected devices. The enFlow fluid warmer was subsequently redesigned with a parylene coating over the heating block. The scientific literature shows that by using a thin parylene layer on the heating block, the leaching of aluminium can be nearly eliminated without affecting the heating performance of the device.


2022 ◽  
pp. 152660282110709
Author(s):  
Naoki Fujimura ◽  
Hideaki Obara ◽  
Takaaki Nagano ◽  
Yukihisa Ogawa ◽  
Taira Kobayashi ◽  
...  

Purpose: To evaluate the efficacy of the Active Seal technology employed in the AFX endovascular aortic aneurysm system (AFX), during endovascular aneurysm repair (EVAR) in patients with abdominal aortic aneurysms (AAAs) having a conical proximal neck. Materials and Methods: A retrospective analysis of the EVAR for AAA with a conical proximal neck using the AFX was performed at 17 Japanese hospitals between January 2016 and August 2020. The conical proximal neck was defined as a cone-shaped proximal neck, with more than 10% diameter increase within a 15 mm length at the proximal landing zone. All anatomical analyses were performed in the core laboratory, and cases with parallel walls within the proximal neck adequate for the landing zone were excluded from the study. Results: This study included 53 patients, but only 39 patients (mean age, 76.6 ± 6.7 years; 87.0% males; mean aneurysm diameter, 52.0 ± 8.0 mm) were analyzed after being characterized as having a pure conical neck by the core laboratory. The mean proximal neck diameters at the lower renal artery and proximal edge of the aneurysm were 20.0 ± 2.9 mm and 27.5 ± 4.9 mm, respectively. The mean proximal neck length was 21.5 ± 6.0 mm. Instructions for use violations other than the conical neck were observed in 15 patients (38.5%). The VELA cuff was used in all cases; however, additional proximal cuff was required in 9 more cases (23.1%). The Active Seal technology was able to significantly extend the proximal sealing zone from 21.5 ± 6.0 to 26.0 ± 12.2 mm ( p = .047). Thirty-six patients completed the 12-month follow-up (one patient was lost to follow-up, and 2 patients died from causes unrelated to the aneurysm), and there were no type-1a and 3 endoleaks with only one reintervention (2.6%) related to type 1b endoleak in the 12-month period. Furthermore, there was no significant enlargement of the proximal neck diameter at 12 months (at 1 month: 20.6 ± 3.4 mm and at 12 months: 21.3 ± 3.8 mm; p = .420). Conclusion: The Active Seal technology of the AFX significantly extended the proximal seal zone and no type-1a endoleak and proximal neck dilation was observed in patients with conical proximal neck at 12 months.


2022 ◽  
pp. 152660282110687
Author(s):  
Jordan R. Stern ◽  
Céline Deslarzes-Dubuis ◽  
Kenneth Tran ◽  
Jason T. Lee

Objectives: The aim of this study was to compare outcomes of patients treated with the Cook Zenith Fenestrated (ZFEN) device for juxtarenal aortic aneurysms inside versus outside the IFU. Methods: We retrospectively reviewed our institutional ZFEN database for cases performed between 2012 and 2018, with analysis performed in 2020 in order to report midterm outcomes. The cohort was stratified based on treatment inside (IFU group) and outside (non-IFU group) the IFU for criteria involving the proximal neck: neck length 4 to 14 mm, neck diameter 19 to 31 mm, and neck angulation ≤45°. Patients with thoracoabdominal aneurysms or concurrent chimney grafting were excluded. The primary outcomes in question were mortality, type 1a endoleak, and reintervention. Univariate and multivariate analyses were performed to determine associations between adherence to IFU criteria and outcomes. Results: We identified 100 consecutive patients (19% female, mean age 73.6 years) for inclusion in this analysis. Mean follow-up was 21.6 months. Fifty-four patients (54%) were treated outside the IFU because of inadequate neck length (n=48), enlarged neck diameter (n=10), and/or excessive angulation (n=16). Eighteen patients were outside IFU for two criteria, and one patient was outside IFU for all three. Non-IFU patients were exposed to higher radiation doses (3652 vs 5445 mGy, p=0.008) and contrast volume (76 vs 95 mL, p=0.004). No difference was noted between IFU and non-IFU groups for 30-day mortality (0% vs 3.7%, p=0.18), or type 1a endoleak (0% vs 1.9%, p=0.41). Reintervention was also similar between cohorts (13% vs 27.8%, p=0.13). Being outside IFU for neck diameter or length was each borderline significant for higher reintervention on univariate analysis (p=0.05), but this was not significant on multivariate Cox proportional hazard modeling (HR 1.82 [0.53–6.25]; 2.03 [0.68–7.89]), respectively. No individual IFU deviations were associated with the primary outcomes on multivariate analysis, nor being outside IFU for multiple criteria. Conclusions: Patients with juxtarenal aortic aneurysms may be treated with the ZFEN device with moderate deviations from the IFU. While no differences were seen in mortality or proximal endoleak, larger studies are needed to examine the potential association between IFU nonadherence and reinterventions and close follow-up is warranted for all patients undergoing such repair.


2022 ◽  
Vol 8 ◽  
Author(s):  
Zheyun Li ◽  
Min Zhou ◽  
Guili Wang ◽  
Tong Yuan ◽  
Enci Wang ◽  
...  

Objective: This study aims to assess the suitability of four types of commercial iliac branch device systems to treat Eastern Asian abdominal aortic aneurysm (AAA) patients with bilateral or unilateral common iliac artery aneurysms (CIAAs).Methods: Patients with a coexisting AAA and a unilateral or bilateral CIAAs who underwent endovascular aneurysm repair (EVAR) at two tertiary centers in China from 2015 to 2017 were reviewed. Morphology of lesions was measured and the anatomic suitability for Cook iliac branch device (IBD), Gore iliac branch endoprosthesis (IBE), Lifetech iliac branch stent graft (IBSG), and Jotec IBD was evaluated according to the latest instructions for use.Results: Seventy-six patients with AAA were enrolled, including 35 bilateral CIAAs, 41 unilateral CIAAs. A hundred and eleven lesions were investigated aggregately: 16.2, 28.8, 21.6, and 19.8% met the criteria for Cook IBD, Gore IBE, Lifetech IBSG, and Jotec IBD, respectively. A total of 34 (44.7%) patients could be treated for at least one lateral lesion. The diameter of the internal iliac artery (IIA) was the most common restriction for IBD application. Additionally, the IIA diameter of lesions in the bilateral group was significantly larger compared with the unilateral group (P < 0.001). Based on the anatomical characteristics alone, it is likely that IBDs will be more suitable for unilateral lesions than bilateral ones (P < 0.05). However, there was no difference between the suitability for patients with unilateral or bilateral CIAAs (P > 0.05).Conclusions: Less than half of Eastern Asian patients with aortoiliac aneurysms were eligible for IBD application. This was primarily due to the IIA diameter failing to meet the criteria. And thus, the suitability of lesions in bilateral group was significantly lower than that in the unilateral group. Aiming to expand the indications and optimize the design of the iliac branch devices, IIA diameter and the anatomical characteristics of the bilateral lesions should be considered deliberately.


2021 ◽  
Vol 3 (1) ◽  
pp. 68-79
Author(s):  
A Kupinskyi ◽  
◽  
I Yurchak

In this project was shown approaches to the implementation of a weather station for monitoring the microclimate in the room on Arduino platform. Considered a platform for project development and software environment. The virtual scheme of the weather station is modeled. The main functions of the components are described and their connection to the microcontroller is shown. The process of firmware of the microcontroller is considered. The algorithm of system operation is described. A functional electrical diagram were also constructed. Described the weather station settings and instructions for use are provided. The device was also tested. Comparisons with analogues are given.


2021 ◽  
Vol 49 (3) ◽  
pp. 596-622
Author(s):  
Noah Bubenhofer

Abstract Visual material plays a central role in lectures to illustrate the spoken word or to show objects of knowledge. Historically, the question arises as to when which methods were used and what their functions were and still are today. In a further diagrammatic perspective on the setting of the lecture, however, other aspects of pictoriality must be included: For example, there is a tradition of storing, commenting on, processing and editing lectures by the audience, which leads, for example, to transcripts that transform the lecture medially. Yet these techniques are embedded in an ensemble of diagrammatic practices of lecture organisation, which can be understood as „instructions for use“ for both lecturers and listeners. From a diagrammatic perspective, it becomes clear that the diagrammatic orders applied in and by lectures are not simply ornaments of the lecture, but have a knowledge-constitutive effect.


2021 ◽  
Vol 5 (2) ◽  
pp. 190-196
Author(s):  
Fitria Lestari

Molecular Biology Analisis Techniques (TABM) is one of the courses that discusses the basic techniques needed for molecular biology. Learning in TABM, is more emphasis on procedural, so the process by using books alone is not enough. Therefore, to support the TABM learning process, interactive were developed consisting of text, sound, images, and research videos. This type of research is R & D is a research and development design by modifying the systematics of Kemp and Dayton. The development steps are to determine the specific learning objectives of the product; prepare material and video content; creating storyboard, developing, editing, and mxing; testing and revising. The instruments used are validation sheets and questionnaires for students with qualitative and quantitative data analysis techniques. Based on the result, there are several suggestions and inputs including: design, instructions for use, product packaging, introduction of tools and initial materials, and procedures. While quantitatively it can be seen that the developed interactive media doesn’t need to be revised and is suitable for use, namely 92,1% of field experts and 70,2% of media experts. It can be concluded that the development of interactive media can be used ini procedural courses such as molecular biological analysis techniques.


Diagnostics ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 2217
Author(s):  
Serge Tonen-Wolyec ◽  
Raphaël Dupont ◽  
Natalio Awaida ◽  
Salomon Batina-Agasa ◽  
Marie-Pierre Hayette ◽  
...  

Due to their ease-of-use, lateral flow assay SARS-CoV-2 antigen-detecting rapid diagnostic tests could be suitable candidates for antigen-detecting rapid diagnostic self-test (Ag-RDST). We evaluated the practicability of the Ag-RDST BIOSYNEX Antigen Self-Test COVID-19 Ag+ (Biosynex Swiss SA, Freiburg, Switzerland), using self-collected nasal secretions from the turbinate medium (NMT), in 106 prospectively included adult volunteers living in Paris, France. The majority of the participants correctly understood the instructions for use (94.4%; 95% confidence interval (CI): 88.3–97.4), showing a great ability to perform the entire self-test procedure to obtain a valid and interpretable result (100%; 95% CI: 96.5–100), and demonstrated the ability to correctly interpret test results (96.2%; 95% CI: 94.2–97.5) with a high level of general satisfaction. About one in eight participants (# 15%) needed verbal help to perform or interpret the test, and only 3.8% of test results were misinterpreted. By reference to multiplex real-time RT-PCR, the Ag-RDST showed 90.9% and 100% sensitivity and specificity, respectively, and high agreement (98.1%), reliability (0.94), and accuracy (90.9%) to detect SARS-CoV-2 antigen. Taken together, our study demonstrates the high usability and accuracy of BIOSYNEX Antigen Self-Test COVID-19 Ag+ for supervised self-collected NMT sampling in an unselected adult population living in France.


2021 ◽  
Vol 8 (Supplement_1) ◽  
pp. S485-S485
Author(s):  
Mylinh Yun ◽  
Jay Varkey ◽  
Daniel Linehan ◽  
Elizabeth Noriega

Abstract Background Central line associated bloodstream infections (CLABSI) are a recognized complication of all central venous access devices including pulmonary artery catheters (PAC). At our institution, PACs are utilized frequently, often for prolonged durations, for patients with advanced heart failure in the cardiac care unit (CCU) who are awaiting heart transplant. In early summer 2018, our hospital infection prevention (IP) department detected an uptick in CLABSI attributable to the CCU. After 9 months of zero CLABSI, two CLABSIs attributable to the CCU were identified during a 3 month period from November 2017-January 2018. Four additional CLABSIs were identified between May-July 2018 prompting an investigation by IP. Review of the 9 CLABSIs attributed to the CCU from May 2018 – June 2019 led IP to prioritize improving PAC insertion practices in our cardiac catheterization lab as a mean to reducing CLABSI (see table 1). Methods IP performed 5 observations of PAC insertion in the cath lab. During the observations of skin preparation, the prep time was performed correctly 40% of the time, correct application 60% of the time and dry time 60% of the time (see table 2, Figure1). Interventions included scheduling a training day for all cath lab staff with the skin prep vendor, performing competency check-offs, and identifying super-users to train future staff. Furthermore, skin antiseptic utilization according the manufacturer's instructions for use was implemented, the coverage area for the applicator was reviewed and a chart for reference was provided.The staff was provided with posters on correct skin prep technique as a visual cue in the procedure room. Results Since the project was implemented in September 2019, there has been 1 CLABSI identified that was possibly related to a PAC inserted in the cath lab. During this time 3 CLABSIs were identified in the CCU but were felt to be unrelated to cath lab insertion. Conclusion Since the project was implemented in September 2019, there has been 1 CLABSI identified that was possibly related to a PAC inserted in the cath lab. During this time 3 CLABSIs were identified in the CCU but were felt to be unrelated to cath lab insertion. Disclosures All Authors: No reported disclosures