saturation effects
Recently Published Documents


TOTAL DOCUMENTS

822
(FIVE YEARS 81)

H-INDEX

48
(FIVE YEARS 6)

Author(s):  
Philipp Zagar ◽  
Rudolf Scheidl

Abstract This paper analyzes dynamic effects of an electro-hydraulic drive which uses a counter-balance valve for rod volume compensation. It shows that local stability analysis is not sufficient in this particular case to get general statements of the system's chattering properties. A reduced-order switched system is proposed to gain deeper insights in system dynamics with saturation effects such as the end-stop of a valve poppet and solutions are compared numerically to the full-system dynamics which incorporates pressure built-up, piston and valve dynamics as well as motor dynamics. It is shown that in cases of e.g. fast valves with small cracking pressures undesirable chattering of the full system exists which can be easily understood in terms of the reduced-order system in form of sliding mode solutions. The paper also describes under which conditions such sliding modes exist, how they behave and how they can be interpreted in terms of the full system.


Author(s):  
Nora-Josefin Breutigam ◽  
Matthias Günther ◽  
Daniel Christopher Hoinkiss ◽  
Klaus Eickel ◽  
Robert Frost ◽  
...  

Abstract Object In this work, we present a technique called simultaneous multi-contrast imaging (SMC) to acquire multiple contrasts within a single measurement. Simultaneous multi-slice imaging (SMS) shortens scan time by allowing the repetition time (TR) to be reduced for a given number of slices. SMC imaging preserves TR, while combining different scan types into a single acquisition. This technique offers new opportunities in clinical protocols where examination time is a critical factor and multiple image contrasts must be acquired. Materials and methods High-resolution, navigator-corrected, diffusion-weighted imaging was performed simultaneously with T2*-weighted acquisition at 3 T in a phantom and in five healthy subjects using an adapted readout-segmented EPI sequence (rs-EPI). Results The results demonstrated that simultaneous acquisition of two contrasts (here diffusion-weighted imaging and T2*-weighting) with SMC imaging is feasible with robust separation of contrasts and minimal effect on image quality. Discussion The simultaneous acquisition of multiple contrasts reduces the overall examination time and there is an inherent registration between contrasts. By using the results of this study to control saturation effects in SMC, the method enables rapid acquisition of distortion-matched and well-registered diffusion-weighted and T2*-weighted imaging, which could support rapid diagnosis and treatment of acute stroke.


2021 ◽  
Vol 9 (5) ◽  
pp. 01-07
Author(s):  
Sheila Veronese ◽  
Marco Cambiaghi ◽  
Andrea Sbarbati

Background: Surgery for applying the auditory brainstem implant is an otoneurosurgery that requires careful intraoperative monitoring to optimize the placement of the electrode paddle. This study aimed to validate a new method capable of increasing the accuracy of electrode array placement, reducing channel interaction, electrical artefacts, and saturation effects, and providing the largest number of electrodes that can be activated with the lowest possible electric charge. Materials and methods: Thirty-six subjects aged between 1.42 and 69.92 years were tested during surgery for auditory brainstem implantation. We recorded auditory electrical responses of the brainstem using the implant supplier's suggested stimulation protocol and the new protocol. Results: Saturations effects and electric artefacts were noticed respectively in 81.85% and 53.25% of recordings using implant supplier's method, while in 70.34% and 24.75% of recordings using the new method, with a percentage variation of 11.51% and 28.50%. Considering the amount of charge required to activate the electrodes, with the implant supplier's method an average charge of 14 nC was needed, while with the new protocol an average charge of 8 nC was necessary. Conclusions: The new method improves the coupling between the auditory brainstem implant and the surface of the cochlear nucleus.


Author(s):  
Peter J. Stafford

AbstractInversions of empirical data and ground-motion models to find Fourier spectral parameters can result in parameter combinations that produce over-saturation of short-period response spectral ordinates. While some evidence for over-saturation in empirical data exists, most ground-motion modellers do not permit this scaling within their models. Host-to-target adjustments that are made to published ground-motion models for use in site-specific seismic hazard analyses frequently require the identification of an equivalent set of Fourier spectral parameters. In this context, when inverting response spectral models that do not exhibit over-saturation effects, it is desirable to impose constraints upon the Fourier parameters to match the scaling of the host-region model. The key parameters that determine whether over-saturation arises are the geometric spreading rate (γ) and the exponential rate within near-source saturation models (hβ). The article presents the derivation of simple nonlinear constraints that can be imposed to prevent over-saturation when undertaking Fourier spectral inversions.


2021 ◽  
Vol 6 (1) ◽  
Author(s):  
S. Kovalev ◽  
K.-J. Tielrooij ◽  
J.-C. Deinert ◽  
I. Ilyakov ◽  
N. Awari ◽  
...  

AbstractTopologically protected surface states present rich physics and promising spintronic, optoelectronic, and photonic applications that require a proper understanding of their ultrafast carrier dynamics. Here, we investigate these dynamics in topological insulators (TIs) of the bismuth and antimony chalcogenide family, where we isolate the response of Dirac fermions at the surface from the response of bulk carriers by combining photoexcitation with below-bandgap terahertz (THz) photons and TI samples with varying Fermi level, including one sample with the Fermi level located within the bandgap. We identify distinctly faster relaxation of charge carriers in the topologically protected Dirac surface states (few hundred femtoseconds), compared to bulk carriers (few picoseconds). In agreement with such fast cooling dynamics, we observe THz harmonic generation without any saturation effects for increasing incident fields, unlike graphene which exhibits strong saturation. This opens up promising avenues for increased THz nonlinear conversion efficiencies, and high-bandwidth optoelectronic and spintronic information and communication applications.


2021 ◽  
Vol 2021 (9) ◽  
Author(s):  
Renaud Boussarie ◽  
Heikki Mäntysaari ◽  
Farid Salazar ◽  
Björn Schenke

Abstract We compute the differential yield for quark anti-quark dijet production in high-energy electron-proton and electron-nucleus collisions at small x as a function of the relative momentum P⊥ and momentum imbalance k⊥ of the dijet system for different photon virtualities Q2, and study the elliptic and quadrangular anisotropies in the relative angle between P⊥ and k⊥. We review and extend the analysis in [1], which compared the results of the Color Glass Condensate (CGC) with those obtained using the transverse momentum dependent (TMD) framework. In particular, we include in our comparison the improved TMD (ITMD) framework, which resums kinematic power corrections of the ratio k⊥ over the hard scale Q⊥. By comparing ITMD and CGC results we are able to isolate genuine higher saturation contributions in the ratio Qs/Q⊥ which are resummed only in the CGC. These saturation contributions are in addition to those in the Weizsäcker-Williams gluon TMD that appear in powers of Qs/k⊥. We provide numerical estimates of these contributions for inclusive dijet production at the future Electron-Ion Collider, and identify kinematic windows where they can become relevant in the measurement of dijet and dihadron azimuthal correlations. We argue that such measurements will allow the detailed experimental study of both kinematic power corrections and genuine gluon saturation effects.


2021 ◽  
Vol 14 (8) ◽  
pp. 5271-5297
Author(s):  
Corinna Kloss ◽  
Vicheith Tan ◽  
J. Brian Leen ◽  
Garrett L. Madsen ◽  
Aaron Gardner ◽  
...  

Abstract. We describe the Airborne Mid-Infrared Cavity enhanced Absorption spectrometer (AMICA) designed to measure trace gases in situ on research aircraft using Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS). AMICA contains two largely independent and exchangeable OA-ICOS arrangements, allowing for the simultaneous measurement of multiple substances in different infrared wavelength windows tailored to scientific questions related to a particular flight mission. Three OA-ICOS setups have been implemented with the aim to measure OCS, CO2, CO, and H2O at 2050 cm−1; O3, NH3, and CO2 at 1034 cm−1; and HCN, C2H2, and N2O at 3331 cm−1. The 2050 cm−1 setup has been characterized in the laboratory and successfully used for atmospheric measurements during two campaigns with the research aircraft M55 Geophysica and one with the German HALO (High Altitude and Long Range Research Aircraft). For OCS and CO, data for scientific use have been produced with 5 % accuracy (15 % for CO below 60 ppb, due to additional uncertainties introduced by dilution of the standard) at typical atmospheric mixing ratios and laboratory-measured 1σ precision of 30 ppt for OCS and 3 ppb for CO at 0.5 Hz time resolution. For CO2, high absorption at atmospheric mixing ratios leads to saturation effects that limit sensitivity and complicate the spectral analysis, resulting in too large uncertainties for scientific use. For H2O, absorption is too weak to be measured at mixing ratios below 100 ppm. By further reducing electrical noise and improving the treatment of the baseline in the spectral retrieval, we hope to improve precision for OCS and CO, resolve the issues inhibiting useful CO2 measurements, and lower the detection limit for H2O. The 1035 and 3331 cm−1 arrangements have only partially been characterized and are still in development. Although both setups have been flown and recorded infrared spectra during field campaigns, no data for scientific use have yet been produced due to unresolved deviations of the retrieved mixing ratios to known standards (O3) or insufficient sensitivity (NH3, HCN, C2H2, N2O). The ∼100 kg instrument with a typical in-flight power consumption of about 500 VA is dimensioned to fit into one 19 in. rack typically used for deployment inside the aircraft cabin. Its rugged design and a pressurized and temperature-stabilized compartment containing the sensitive optical and electronic hardware also allow for deployment in payload bays outside the pressurized cabin even at high altitudes of 20 km. A sample flow system with two parallel proportional solenoid valves of different size orifices allows for precise regulation of cavity pressure over the wide range of inlet port pressures encountered between the ground and maximum flight altitudes. Sample flow of the order of 1 SLM (standard litre per minute) maintained by an exhaust-side pump limits the useful time resolution to about 2.5 s (corresponding to the average cavity flush time), equivalent to 500 m distance at a typical aircraft speed of 200 m s−1.


2021 ◽  
Vol 81 (8) ◽  
Author(s):  
A. van Hameren ◽  
P. Kotko ◽  
K. Kutak ◽  
S. Sapeta ◽  
E. Żarów

AbstractWe propose a novel way of studying the gluon number density (the so-called Weizsäcker–Williams gluon distribution) using the planned Electron Ion Collider. Namely, with the help of the azimuthal correlations between the total transverse momentum of the dijet system and the scattered electron, we examine an interplay between the effect of the soft gluon emissions (the Sudakov form factor) and the gluon saturation effects. The kinematic cuts are chosen such that the dijet system is produced in the forward direction in the laboratory frame, which provides an upper bound on the probed longitudinal fractions of the hadron momentum carried by scattered gluons. Further cuts enable us to use the factorization formalism that directly involves the unpolarized Weizsäcker–Williams gluon distribution. We find this observable to be very sensitive to the soft gluon emission and moderately sensitive to the gluon saturation.


Sign in / Sign up

Export Citation Format

Share Document