radiation detectors
Recently Published Documents


TOTAL DOCUMENTS

1812
(FIVE YEARS 216)

H-INDEX

50
(FIVE YEARS 6)

Author(s):  
Yunuen Cervantes ◽  
Simon Duane ◽  
Hugo Bouchard

Abstract With the integration of MRI-linacs to the clinical workflow, the understanding and characterization of detector response in reference dosimetry in magnetic fields are required. The magnetic field perturbs the electron fluence (Fe), and the degree of perturbation depends on the irradiation conditions and the detector type. This work evaluates the magnetic field impact on the electron fluence spectra in several detectors to provide a deeper understanding of detector response in these conditions. Monte Carlo calculations of Fe are performed in six detectors (solid-state: PTW60012 and PTW60019, ionization chambers: PTW30013, PTW31010, PTW31021, and PTW31022) placed in water and irradiated by an Elekta Unity 7 MV FFF photon beam with small and reference fields, at 0 T and 1.5 T. Three chamber-axis orientations are investigated: parallel or perpendicular (two possibilities: FL towards the stem or the tip) to the magnetic field and perpendicular to the beam. One orientation for the solid-state detector is studied: parallel to the beam and perpendicular to the magnetic field. Additionally, Fe spectra are calculated in modified detector geometries to identify the underlying physical mechanisms behind the fluence perturbations. The total Fe is reduced up to 1.24% in the farmer chamber, at 1.5 T, in the parallel orientation. The interplay between the gyration radius and the farmer chamber cavity length significantly affects Fe in the perpendicular orientation; the total fluence varies up to 5.12% in magnetic fields. For the small-cavity chambers, the maximal variation in total Fe is 0.19%, for the reference field, in the parallel orientation. . In contrast, significant small-field effects occur; the total Fe is reduced between 9.86% to 14.50% at 1.5T (with respect to 0T) depending on the orientation. The magnetic field strongly impacted the solid-state detectors in both field sizes, probably due to the high-density extracameral components. The maximal reductions of total Fe are 15.06±0.09% (silicon) and 16.00±0.07% (microDiamond). This work provides insights into detector response in magnetic fields by illustrating the interplay between several factors causing dosimetric perturbation effects: 1) chamber and magnetic field orientation, 2) cavity size and shape, 3) extracameral components, 4) air gaps and their asymmetry, 5) electron energy. Low-energy electron trajectories are more susceptible to change in magnetic fields, and generally, they are associated with detector response perturbation.


Materials ◽  
2022 ◽  
Vol 15 (1) ◽  
pp. 388
Author(s):  
Mauricio R. Ramos ◽  
Andreo Crnjac ◽  
Donny Cosic ◽  
Milko Jakšić

Synthetic single crystal diamond grown using the chemical vapor deposition technique constitutes an extraordinary candidate material for monitoring radiation in extreme environments. However, under certain conditions, a progressive creation of space charge regions within the crystal can lead to the deterioration of charge collection efficiency. This phenomenon is called polarization and represents one of the major drawbacks associated with using this type of device. In this study, we explore different techniques to mitigate the degradation of signal due to polarization. For this purpose, two different diamond detectors are characterized by the ion beam-induced charge technique using a nuclear microprobe, which utilizes MeV energy ions of different penetration depths to probe charge transport in the detectors. The effect of polarization is analyzed by turning off the bias applied to the detector during continuous or discontinuous irradiation, and also by alternating bias polarity. In addition, the beneficial influence of temperature for reducing the effect of polarization is also observed. Finally, the effect of illuminating the detector with light is also measured. Our experimental results indicate that heating a detector or turning off the bias, and then applying it during continuous irradiation can be used as satisfactory methods for recovering the CCE value close to that of a prepolarized state. In damaged regions, illumination with white light can be used as a standard method to suppress the strength of polarization induced by holes.


CrystEngComm ◽  
2022 ◽  
Author(s):  
Wanzhong Li ◽  
Jian Sun ◽  
Chong Deng

Cadmium Zinc Telluride (CdZnTe) single crystals have been widely ultilized in various photoelectron devices such as radiation detectors and solar cells. Different types of ordered phases have also been investigated...


2021 ◽  
Vol 9 (6) ◽  
pp. 499-512
Author(s):  
Nikolay Kulchitsky ◽  
Arkadii Naumov ◽  
Vadim Startsev ◽  
Mikhail Dem’yanenko

The paper discusses the problems associated with the development of technology for terahertz radiation detectors. The main physical phenomena and recent progress in various methods of detecting terahertz radiation (direct detection and heterodyne detection) are considered. Advantages and disadvantages of direct detection sensors and sensors with heterodyne detection are discussed. In part 1, a number of features of direct detection are considered and some types of terahertz direct detection detectors are described. Part 2 will describe heterodyne detection and continue to describe some types of modern photonic terahertz receivers.


2021 ◽  
pp. 49-74
Author(s):  
Elizabeth Benson

2021 ◽  
Author(s):  
Ihor Fodchuk ◽  
Andrii Kuzmin ◽  
Olena Maslyanchuk ◽  
Ivan Hutsuliak ◽  
Mykola Solodkyi ◽  
...  

2021 ◽  
Author(s):  
Diana Bachiller-Perea ◽  
Mingming Zhang ◽  
Celeste Fleta ◽  
David Quirion ◽  
Daniela Bassignana ◽  
...  

Abstract Purpose: The present work reports on the microdosimetry measurements performed with the two first multi-arrays of microdosimeters with the highest radiation sensitive surface covered so far. The sensors are based on new silicon-based radiation detectors with a novel 3D cylindrical architecture. Methodology: Each system consists of arrays of independent microdetectors covering 2 mm×2 mm and 0.4 mm×12 cm radiation sensitive areas, the sensor distributions are arranged in layouts of 11×11 microdetectors and 3×3 multi-arrays, respectively. We have performed proton irradiations at several energies to compare the microdosimetry performance of the two systems, which have different spatial resolution and detection surface. The unit-cell of both arrays is a new type of 3D cylindrical diode with a 25 µm diameter and a 20 µm depth that results in a well-defined and isolated radiation sensitive micro-volume etched inside a silicon wafer. Measurements were carried out at the Accélérateur Linéaire et Tandem à Orsay (ALTO) facility by irradiating the two detection systems with monoenergetic proton beams from 6 to 18 MeV at clinical-equivalent fluence rates. Results: The microdosimetry quantities were obtained with a spatial resolution of 200 µm and 600 µm for the 11×11 system and for the 3×3 multi-array system, respectively. Experimental results were compared with Monte Carlo simulations and an overall good agreement was found. Conclusion: We have studied the microdosimetry response under clinical equivalent fluence rate of the first multi-arrays of 3D cylindrical microdetectors covering several centimeters of sensitive area. The good performance of both microdetector arrays demonstrates that this architecture and both configurations can be used clinically as microdosimeters for measuring the lineal energy distributions and, thus, for RBE optimization of hadron therapy treatments. Likewise, the results have shown that the devices can be also employed as a multipurpose device for beam monitoring in particle accelerators.


2021 ◽  
Vol 11 (23) ◽  
pp. 11368
Author(s):  
Irina Valitova ◽  
Alexandria Mitchell ◽  
Michael A. Hupman ◽  
Ian G. Hill ◽  
Alasdair Syme

Interest in the use of organic electronic devices in radiation sensing applications has grown in recent years. The numerous device configurations (e.g., diodes, thin film transistors) and potential for improved tissue equivalence compared to their silicon-based analogues make them attractive candidates for various radiation dosimetry measurements. In this work, a variation of the organic thin film transistor (OTFT) is studied, in which a polymer electret is added. An OTFT electret design can be used in either a wired or wireless configuration for in vivo dosimetry with the possibility of real-time detection. The linearity, reproducibility, and dependence on energy of these devices were measured through exposure to 100 kVp photons from an orthovoltage treatment unit (Xstrahl 300) and 6 MV photons from a Varian TrueBeam medical linear accelerator. Prior to irradiation, all transistors were programmed with a −80 V bias applied to the Gate electrode (Vg) for 3 s. In the wireless configuration, after each delivered dose, the transfer characteristic was scanned to readout the amount of erased charges by monitoring the drain current change. When the programmed charge was sufficiently depleted by radiation, transistors were reprogrammed for repeated use. The real-time readout in a wired configuration was performed by measuring the drain current with Vg = −15 V; Vd = −15 V. The 6 MV photon beam was turned on and off at different dose rates of 600, 400, 300, 200, and 60 cGy/min to quantify the sensitivity of the device to changes in dose rate. The wireless transistors showed a linear increase in current with increasing dose. The sensitivities for different energies were 60 ± 5 nA/Gy at 6 MV at a dose rate of 600 cGy/min and 80 ± 10 nA/Gy at 100 kVp at a dose rate of 200 cGy/min. The sensitivity of detectors tested in a wired configuration at Vd = −15 V; Vg = −15 V was 8.1 nA/s at a dose rate of 600 cGy/min. The principle of pentacene OTFTs with polymer electret as radiation detectors was demonstrated. Devices had excellent linearity, reproducibility, and were able to be reprogrammed for multiple uses as wireless detectors. The wired transistors demonstrated an effective response as real-time detectors.


2021 ◽  
Vol 16 (12) ◽  
pp. C12027
Author(s):  
A. Krzyzanowska

Abstract Hybrid pixel radiation detectors working in a single-photon counting mode have gained increasing attention due to their noiseless imaging and high dynamic range. Due to the fact that sensors of different materials can be attached to the readout circuit, they allow operation with a wide range of photon energies. The performance of the single photon counting detectors is limited by pile-up. To allow a detector to work under high flux conditions, the pixel size is reduced, which minimizes detector dead time. However, with smaller pixel sizes the charge sharing effect, a phenomenon that deteriorates both detection efficiency and spatial resolution is more profound. The influence of charge sharing on the detector performance can be quantified using parameterization of the s-curve obtained in the spectral response measurements. The article presents the measurements of the response function of a hybrid pixelated photon counting detector for certain primary energy, which corresponds to the probability of detecting a photon as a function of its energy deposition. The measurements were carried out using an X-ray tube by performing a threshold scan during illumination with X-ray photons of a 1.5 mm and 0.75 mm thick CdTe detector with 100 µm pixel pitch. The charge size cloud depends on the sensor material, the bias voltage, and the sensor thickness. Therefore, the experimental data from a sensor biased with different bias voltages are compared to the theoretical results based on a cascaded model of a single-photon counting segmented silicon detector. The study of the charge sharing influence on the spatial resolution of the CdTe detector will serve for a further study of the possible implementations of the algorithms achieving subpixel resolution, in which the charge sharing becomes the desired effect since the charge division in the pixels is used to interpolate the photon interaction position.