radiographic measurement
Recently Published Documents


TOTAL DOCUMENTS

255
(FIVE YEARS 51)

H-INDEX

27
(FIVE YEARS 1)

2022 ◽  
Vol 0 (0) ◽  
Author(s):  
Uros Meglic ◽  
Oskar Zupanc

Abstract Background Identifying the location and scale of radiographic changes in elbow bony impingement (EBI) is critical in formulating an appropriate diagnosis and treatment plan for such patients. The purpose of present study was to evaluate the intra-rater and inter-rater reliability of the new radiographic parameters, Anterior Impingement angle (AIa) and Posterior Impingement angle (PIa), for EBI. In addition, to determine if there was a relationship between radiographic parameters and clinical evaluation. Patients and methods Three raters of different levels of training evaluated the radiographs of 60 patients (30 in EBI group and 30 in normal group) twice, at least 2 weeks apart. Intra-rater and inter-rater reliabilities were calculated by Intraclass Correlation Coefficients (ICC) with 95% confidence intervals. Correlation between radiographic parameters and clinical evaluation was calculated by Pearson correlation coefficient. Results In both groups, intra-rater and inter-rater reliabilities were substantial. There were no significant differences in reliability between upper-hand expert surgeons and resident for either measurement. Good correlation was observed between impingement arcs and range of motion values. Conclusions Both AIa and PIa measurements demonstrated substantial intra-rater and inter-rater reliability for normal radiographs and in EBI patients. Good reliability, for either expert surgeons or residents in training, and good correlation between radiographic measurements and manual testing, appoints this method may be easily and reliably used in every day practice.


2021 ◽  
Vol 8 ◽  
Author(s):  
Zhao Yang ◽  
Yang Liu ◽  
Longtao Qi ◽  
Shanshan Wu ◽  
Jingwen Li ◽  
...  

Background: Halo-gravity traction is a commonly used clinical intervention to reduce surgical risk in patients with scoliosis before surgical correction. Some previous studies have focused on the application of halo-gravity traction on patients with severe spinal deformity and pulmonary insufficiency, but the overall effect of halo-gravity traction has not been fully understood. The object of the present study was to perform a meta-analysis exploring the efficacy of preoperative halo-gravity traction on radiographic measurement and pulmonary function in severe scoliosis patients with pulmonary insufficiency.Methods: We searched the medical works of literature completed before January 17, 2021, in the databases of Pubmed, Embase, and Cochrane Library. Studies that quantitatively analyzed the effects of halo-gravity traction on the deformity and pulmonary functions of patients with severe scoliosis were included. Two researchers independently conducted the literature search, data extraction, and quality assessment. We used the Review Manager Software (version 5.4) for statistical analysis and data analysis. Mean difference (MD) with 95% confidence intervals (CIs) were calculated to evaluate the effects of halo-gravity traction.Results: Seven studies involving 189 patients received halo-gravity traction therapy preoperatively were analyzed in our study. Preoperative halo-gravity traction significantly ameliorated the degree of deformity in severe scoliosis patients with pulmonary insufficiency, especially reduced coronal Cobb angle and sagittal Cobb angle effectively [mean deviation (MD) = 2 7.28 (95%CI 21.16–33.4), p < 0.001; MD = 22.02 (95%CI 16.8–27.23), p < 0.001]. Preoperative halo-gravity traction also improved the pulmonary functions in patients, especially increasing %FVC and %FEV1 [MD = −0.0662 (95%CI −0.0672–−0.0652), p < 0.001; MD = −0.0824 (95%CI −0.0832–−0.081), p < 0.001].Conclusions: Preoperative halo-gravity traction for severe scoliosis patients shows significant improvement in the degree of deformity and pulmonary functions. Halo-gravity traction is an effective method to improve the tolerance of patients to surgery in the perioperative period.


Author(s):  
Arisa Leungbootnak ◽  
Rungthip Puntumetakul ◽  
Jaturat Kanpittaya ◽  
Thiwaphon Chatprem ◽  
Rose Boucaut

Lumbar instability (LI) comprises one subgroup of those with chronic low back pain (CLBP); it indicates the impairment of at least one of the spinal stabilizing systems, and radiographic criteria of translation and rotation are used for its diagnosis. Previous studies have developed and tested a screening tool for LI where patients with sub-threshold lumbar instability (STLI) were detected in the initial stage of lumbar pathology using radiographs as a gold standard for diagnosis. The radiographic measurement in STLI lies between the range of translation and rotation of the LI and asymptomatic lumbar motion. However, there are no studies indicating the validity and cut-off points of the screening tool for STLI. The current study aimed to determine the validity of an LI screening tool to support the diagnostic process in patients with STLI. This study design was cross-sectional in nature. A total of 135 participants with CLBP, aged between 20 and 60 years, who had undergone flexion and extension radiographs, answered a screening tool with 14 questions. The cut-off score for identifying STLI using the screening tool was at least 6/14 positive responses to the LI questions. The findings suggested that the LI screening tool we tested is effective for the detection of STLI. The tool can be used in outpatient settings.


2021 ◽  
Author(s):  
Małgorzata Deręgowska-Cylke ◽  
Piotr Palczewski ◽  
Marcin Błaż ◽  
Radosław Cylke ◽  
Paweł Ziemiański ◽  
...  

Abstract Background As a restrictive procedure, laparoscopic sleeve gastrectomy (LSG) relies primarily on the reduction of gastric volume. It has been suggested that an immediate postoperative gastric remnant volume (GRV) may influence long-term results of LSG; however, there are no consensus in this matter. The aim of this study was to assess the reproducibility of different radiographic methods of GRV calculation and evaluate their correlation with the weight loss (WL) after surgery. Methods This retrospective study evaluated 174 patients who underwent LSG in the period from 2014 to 2017. Using UGI, GRV was measured with 3 different mathematical methods by 2 radiologists. Intraobserver and interobserver calculations were made. Correlation between GRV and WL were estimated with calculations percentage of total weight loss (%TWL) and percentage of excess weight loss (%EWL) after 1, 3, 6, 12, 18, and 24 months postoperatively. Results During analysis of intraobserver similarities, the results of ICC calculation showed that reproducibility was good to excellent for all GRV calculation methods. The intraobserver reproducibility for Reader I was highest for cylinder and truncated cone formula and for Reader II for ellipsoid formula. The interobserver reproducibility was highest for ellipsoid formula. Regarding correlation between GRV and WL, significant negative correlation has been shown on the 12th month after LSG in %TWL and %EWL for every method of GRV calculation, most important for ellipsoid formula (%TWL – r(X,Y) = -0.335, p < 0.001 and %EWL – r(X,Y) = -0.373, p < 0.001). Conclusion Radiographic methods of GRV calculation are characterized by good reproducibility and correlate with the postoperative WL. Graphical Abstract


2021 ◽  
Vol 7 (4) ◽  
pp. 484-487
Author(s):  
Bikramjit Gayen ◽  
Dipak Kumar Jha ◽  
Prasanta Kumar Pujari ◽  
Chandrachur Bhattacharya ◽  
Syamsundar Mondal

Author(s):  
Yunsir Choi ◽  
Joanna Pilton ◽  
Timothy Foo ◽  
Richard Malik ◽  
Bianca Haase

Abstract Objective The aim of this study was to create a feline reference database for the length, width and slenderness (length to width ratio) of metacarpal and metatarsal bones, radius and tibia. Study Design Radiographs of the radius, tibia, metacarpus and metatarsus were performed in domestic short hair cat cadavers (n = 40). Length and width of the aforementioned bones were measured in mature domestic shorthair cats and bone slenderness (length/width) and index ratios calculated. Results A significant skeletal sex dimorphism exists in cats, with bones of the metacarpus, metatarsus, radius and tibia generally longer and wider in male cats compared with female cats, with differences frequently significant. The most significant difference was identified for the width of Mc5 (p = 0.0008) and the length and width of Mt5 (p = 0.0005). Index ratios for length and width of radius to metacarpal bones, and tibia to metatarsal bones, were not significantly different between male and female cats, except for Mc5. The index ratio for Mc5 was significantly higher in male cats (p = 0.002). Conclusion The present study provides insights into the normal length and width of distal forelimb and hind limb bones as well as bone index ratios in mature domestic shorthair cats. Using this information, it is now possible to quantitatively assess the relationship between these bones in domestic cats using radiography. This will assist not only with the diagnosis and categorization of skeletal abnormalities but can also guide surgical interventions of metacarpal and metatarsal bone fractures.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
M. Severyns ◽  
M.-E. Rollet ◽  
T. Vendeuvre ◽  
S. Pesenti ◽  
A. Benzakour ◽  
...  

Abstract Background The aim of this cadaver study was to evaluate an original technique for measuring posterior tibial translation based on an angle value instead of a distance value, with and without posterior stress application. It was hypothesized that an angle measurement of the posterior tibial translation would confirm the presence of a PCL tear with the knee flexed and completely extended. Method Using fresh cadavers, a set of strict lateral views were taken by fluoroscopy with the knee at 0°, 45° and 90° flexion on the intact knee and after transecting the PCL. The primary endpoint was the change in the posterior translation measured using a new technique, the ABC angle. This measurement was compared to the conventional posterior translation distance measurement with and without a posterior stress placed on the knee. Results Application of a posterior stress revealed clear changes in posterior translation after PCL transection with the knee at 0° for the angle technique and at 45° and 90° for the two techniques (p < 0.05). Contrary to the reference method, the ABC angle method found a statistically significant difference in posterior translation with the knee in extension. Conclusion Our technique provides a reliable radiographic measurement of posterior translation with the knee in extension, which should make it easier to acquire radiographs in patients who have pain with knee flexion. This angular measurement also has the advantage of not needing length calibration contrary to the reference technique. Level of evidence IV


Author(s):  
Hideki Ohashi ◽  
Keiichiro Nishida ◽  
Yoshihisa Nasu ◽  
Kenta Saiga ◽  
Ryuichi Nakahara ◽  
...  

Dorsal dislocation of metatarsophalangeal (MTP) joints of the lesser toe frequently occurs in patients with rheumatoid arthritis (RA), and may cause painful and uncomfortable plantar callosities and ulceration. The current study examined the reliability and clinical relevance of a novel radiographic parameter (the MTP overlap distance [MOD]) in evaluating the severity of MTP joint dislocation. The subjects of the current study were 147 RA patients (276 feet; 1104 toes). MOD, defined as the overlap distance of the metatarsal head and the proximal end of the phalanx, was measured on plain radiographs. The relationship between the MOD and clinical complaints (forefoot pain and/or callosity formation) was analyzed to create a severity grading system. As a result, toes with callosities had a significantly larger MOD. ROC analysis revealed that the MOD had a high AUC for predicting an asymptomatic foot (−0.70) and callosities (0.89). MOD grades were defined as follows: grade 1, 0 ≤ MOD < 5 mm; grade 2, 5 ≤ MOD < 10 mm; and grade 3, MOD ≥ 10 mm. The intra- and inter-observer reliability of the MOD grade had high reproducibility. Furthermore, the MOD and MOD grade improved significantly after joint-preserving surgeries for lesser toe deformities. Our results suggest that MOD and MOD grade might be useful tools for the evaluation of deformities of the lesser toe and the effect of surgical intervention for MTP joints in patients with RA.


2021 ◽  
pp. 155633162110263
Author(s):  
Ting Cong ◽  
Ahilan Sivaganesan ◽  
Christopher M. Mikhail ◽  
Avani S. Vaishnav ◽  
James Dowdell ◽  
...  

Background: The gold standard for percutaneous pedicle screw placement is 2-dimensional (2D) fluoroscopy. Data are sparse on the accuracy of 3-dimensional (3D) navigation percutaneous screw placement in minimally invasive spine procedures. Objective: We sought to compare a single surgeon’s percutaneous pedicle screw placement accuracy using 2D fluoroscopy versus 3D navigation, as well as to investigate the effect of facet orientation on facet violation when using 2D fluoroscopy. Methods: We conducted a retrospective radiographic study of consecutive cohort of patients who underwent percutaneous lumbar instrumentation using either 2D fluoroscopy or 3D navigation. All procedures were performed by a single surgeon at 2 academic institutions between 2011 and 2018. Radiographic measurement of screw accuracy was assessed using a postoperative computed tomographic scan. The primary outcome was facet violation, and secondary outcomes were endplate/tip breaches, the Gertzbein-Robbins classification for cortical breaches, and the Simplified Screw Accuracy grade. Statistical comparisons were made between screws placed using 2D fluoroscopy versus 3D navigation. Axial facet angles were also measured to correlate with facet violation rates. Results: In the 138 patients included, 376 screws were placed with fluoroscopy and 193 with navigation. Superior (unfused) level facet violation was higher with 2D fluoroscopy than with 3D navigation (9% vs 0.5%), which comprises the main cause for poor screw placement. Axial facet angles exceeding 45° at L4 and 60° at L5 were correlated with facet violations. Conclusion: This retrospective study found that 3D navigation is associated with lower facet violation rates in percutaneous lumbar pedicle screw placement when compared with 2D fluoroscopy. These findings suggest that 3D navigation may be of particular value when facet joints are coronally oriented.


2021 ◽  
Vol 64 (4) ◽  
pp. E442-E448
Author(s):  
Xin Yu Mei ◽  
Ali Etemad-Rezaie ◽  
Oleg A. Safir ◽  
Allan E. Gross ◽  
Paul R. Kuzyk

Background: Acetabular component malposition is a major cause of dislocation following total hip arthroplasty (THA). Intellijoint HIP is an imageless navigation tool that has been shown to provide accurate intraoperative measurement of cup position during primary THA without substantially increasing operative time. However, its accuracy in revision THA has not been evaluated. This study therefore aims to assess the accuracy of Intellijoint HIP in measuring cup inclination and anteversion in comparison with computed tomography (CT) during revision THA. Methods: Intellijoint HIP was used to measure the position of the preexisting cup in 53 consecutive patients undergoing revision THA between December 2018 and February 2020. Two authors blinded to the intraoperative navigation measurements also independently measured cup position using preoperative CT according to Murray’s radiographic definitions. Pearson correlation coefficients with 95% confidence intervals (CIs), paired t tests and Bland–Altman plots were used to assess agreement between navigation- and CT-measured cup position. Statistical analysis was performed using GraphPad Prism, with p values less than 0.05 indicating statistical significance. Results: There was excellent agreement between navigation and CT measurements for both cup inclination (r = 0.89, 95% CI 0.81–0.93) and anteversion (r = 0.93, 95% CI 0.88–0.96), with the mean absolute difference being 5.2º (standard deviation [SD] 4.0º) for inclination and 4.8º (SD 5.4º) for anteversion. The navigation measurement was within 10º of the radiographic measurement in 47 of 53 (88.7%) cases for inclination and 46 of 53 (86.8%) cases for anteversion. Conclusion: Imageless navigation demonstrated excellent correlation and agreement with CT measurements for both inclination and anteversion over a wide range of acetabular component positions.


Sign in / Sign up

Export Citation Format

Share Document