eiken chemical
Recently Published Documents


TOTAL DOCUMENTS

10
(FIVE YEARS 9)

H-INDEX

1
(FIVE YEARS 1)

Cells ◽  
2021 ◽  
Vol 10 (8) ◽  
pp. 1931
Author(s):  
Marianna Soroka ◽  
Barbara Wasowicz ◽  
Anna Rymaszewska

In 1998, when the PCR technique was already popular, a Japanese company called Eiken Chemical Co., Ltd. designed a method known as the loop-mediated isothermal amplification of DNA (LAMP). The method can produce up to 109 copies of the amplified DNA within less than an hour. It is also highly specific due to the use of two to three pairs of primers (internal, external, and loop), which recognise up to eight specific locations on the DNA or RNA targets. Furthermore, the Bst DNA polymerase most used in LAMP shows a high strand displacement activity, which eliminates the DNA denaturation stage. One of the most significant advantages of LAMP is that it can be conducted at a stable temperature, for instance, in a dry block heater or an incubator. The products of LAMP can be detected much faster than in standard techniques, sometimes only requiring analysis with the naked eye. The following overview highlights the usefulness of LAMP and its effectiveness in various fields; it also considers the superiority of LAMP over PCR and presents RT-LAMP as a rapid diagnostic tool for SARS-CoV-2.


Author(s):  
Faria Hossain ◽  
Albert Picado ◽  
Sophie I. Owen ◽  
Prakash Ghosh ◽  
Rajashree Chowdhury ◽  
...  

With reduced prevalence of visceral leishmaniasis (VL) in the Indian subcontinent (ISC), direct and field deployable diagnostic tests are needed to implement an effective diagnostic and surveillance algorithm for post-elimination VL control. In this regard, here we investigated the diagnostic efficacies of a loop-mediated isothermal amplification (LAMP) assay (Loopamp™ Leishmania Detection Kit, Eiken Chemical CO., Ltd, Japan), a real-time quantitative PCR assay (qPCR) and the Leishmania antigen ELISA (CLIN-TECH, UK) with different sampling techniques and evaluated their prospect to incorporate into post-elimination VL control strategies. Eighty clinically and rK39 rapid diagnostic test confirmed VL cases and 80 endemic healthy controls were enrolled in the study. Peripheral blood and dried blood spots (DBS) were collected from all the participants at the time of diagnosis. DNA was extracted from whole blood (WB) and DBS via silica columns (QIAGEN) and boil & spin (B&S) methods and tested with qPCR and Loopamp. Urine was collected from all participants at the time of diagnosis and was directly subjected to the Leishmania antigen ELISA. 41 patients were followed up and urine samples were collected at day 30 and day 180 after treatment and ELISA was performed. The sensitivities of the Loopamp-WB(B&S) and Loopamp-WB(QIA) were 96.2% (95% CI 89·43-99·22) and 95% (95% CI 87·69-98·62) respectively. The sensitivity of Loopamp-DBS(QIA) was 85% (95% CI 75·26- 92·00). The sensitivities of the qPCR-WB(QIA) and qPCR-DBS(QIA) were 93.8% (95% CI 86·01-97·94) and 72.5% (95% CI 61·38-81·90) respectively. The specificity of all molecular assays was 100%. The sensitivity and specificity of the Leishmania antigen ELISA were 97.5% (95% CI 91·47-99·70) and 91.95% (95% CI 84·12-96·70) respectively. The Leishmania antigen ELISA depicted clinical cure at day 180 in all the followed-up cases. Efficacy and sustainability identify the Loopamp-WB(B&S) and the Leishmania antigen ELISA as promising and minimally invasive VL diagnostic tools to support VL diagnostic and surveillance activities respectively in the post-elimination era.


2021 ◽  
Vol 9 (3) ◽  
pp. 610
Author(s):  
Ana Victoria Ibarra-Meneses ◽  
Carmen Chicharro ◽  
Carmen Sánchez ◽  
Emilia García ◽  
Sheila Ortega ◽  
...  

Loop-mediated isothermal amplification allows the rapid, sensitive and specific amplification of DNA without complex and expensive equipment. We compared the diagnostic performance of Loopamp™ Leishmania Detection Kit (Eiken Chemical Co., Ltd., Tokyo, Japan) with conventional and real-time polymerase chain reaction (PCR) for human cutaneous and visceral leishmaniasis caused by L. infantum. A total of 230 DNA samples from cutaneous (CL) and visceral (VL) leishmaniasis cases and controls from Spain, characterized by Leishmania nested PCR (LnPCR) were tested by: (i) the Loopamp™ Leishmania Detection Kit (Loopamp), run on Genie III real-time fluorimeter (OptiGene, UK); and (ii) real-time quantitative PCR (qPCR). The Loopamp test returned 98.8% (95% confidence interval—CI: 96.0–100.00) sensitivity and specificity of 97.7% (95% CI: 92.2–100) on VL samples, and 100% (95% CI: 99.1–100) sensitivity and 100.0% (95% CI: 98.8–100.0) specificity on CL samples. The Loopamp time-to-positivity (Tp) obtained by real-time fluorimetry showed excellent concordance (C = 97.91%) and strong correlation (r = 0.799) with qPCR’s cycle threshold (Ct). The performance of Loopamp is comparable to that of LnPCR and qPCR in the diagnosis of cutaneous and visceral leishmaniasis due to L. infantum. The excellent correlation between the Tp and Ct should be further investigated to determine the accuracy of Loopamp to quantify parasite load in tissues.


Author(s):  
Maria D. Flores-Chavez ◽  
Alba Abras ◽  
Cristina Ballart ◽  
Ismael Ibáñez Perez ◽  
Pilar Perez-Gordillo ◽  
...  

Background: In Spain, polymerase chain reaction (PCR) is the tool of choice for the diagnosis of congenital Chagas disease (CD) and serology for diagnosing chronic CD. A loop-mediated isothermal amplification test for Trypanosoma cruzi DNA detection showed a good analytical performance and ease of use. We aimed to evaluate the performance of the Loopamp™ Trypanosoma cruzi Detection Kit, Eiken Chemical Co. Ltd., Japan (Tcruzi-LAMP) for congenital and chronic CD diagnosis using well-characterized samples. Methods: We included samples from 39 congenital and 174 chronic CD cases, and from 48 uninfected children born to infected mothers and 34 non-chagasic individuals. Sensitivity, specificity and accuracy of Tcruzi-LAMP was estimated using standard case definitions for congenital CD (positive result by parasitological or PCR tests or serology after nine months of age) and chronic CD (positive serology by at least two tests). The Tcruzi-LAMP results were read by visual examination and a real-time fluorimeter. Results: For congenital CD, Tcruzi-LAMP sensitivity was 97% for both types of reading; specificity was 92% by visual examination and 94% by fluorimeter. For chronic CD, sensitivity was 47% and specificity 100%. The accuracy in congenital CD was >94% vs 56% in chronic CD. The agreement of Tcruzi-LAMP with PCR tests was better in congenital CD (kappa 0.86 to 0.91) than in chronic CD (kappa 0.67 to 0.83). Conclusions: The Loopamp™ Trypanosoma cruzi Detection Kit showed a good performance for the diagnosis of congenital CD. Tcruzi-LAMP, like PCR, can be useful for the screening and early diagnosis of congenital infection.


2020 ◽  
Vol 57 (3) ◽  
pp. 316-322
Author(s):  
Rejane MATTAR ◽  
Sergio Barbosa MARQUES ◽  
Maurício Kazuyoshi MINATA ◽  
Joyce Matie Kinoshita da SILVA-ETTO ◽  
Paulo SAKAI ◽  
...  

ABSTRACT BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.


2019 ◽  
Vol 15 (1) ◽  
Author(s):  
Stine Jacobsen ◽  
Anne Mette Vinther ◽  
Mads Kjelgaard-Hansen ◽  
Lise Nikolic Nielsen

Abstract Background Serum amyloid A (SAA) is a major equine acute phase protein and of great value in detection and monitoring of inflammation. A new immunoturbidometric assay based on monoclonal antibodies (VET-SAA, Eiken Chemical Co., Japan) may be useful for SAA measurements in routine diagnostic laboratories. The aim of the study was to validate the VET-SAA immunoturbidometric assay and use it to measure serum SAA concentrations in a variety of clinical cases. Precision was assessed by intra- and interassay coefficients of variation of repeated measurements of serum pools (low, intermediate, high concentrations of SAA). Accuracy was estimated by linearity under dilution. Detection limit was determined by replicate determinations of ionized water. Measurements were compared to measurements performed in a previously validated SAA assay (LZSAA assay, Eiken Chemical Co., Japan). Subsequently, the VET-SAA assay was used for measuring serum SAA concentrations in horses with and without inflammation. Results Detection limit was 1.2 mg/L. Without modifications, the assay measured SAA concentrations with acceptable reliability in a broad concentration range (0 to > 6000 mg/L). In the 0–3000 mg/L range, the assay demonstrated good precision and accuracy, and concentrations correlated well with those obtained in the LZSAA assay, albeit with a slight systematic bias. Concentrations of SAA assessed in horses with and without inflammation followed the expected pattern, with significantly higher concentrations in horses with systemic inflammation than in healthy horses and horses with non-inflammatory disease. Conclusions The assay was unique in its ability to measure SAA concentrations with acceptable reliability over an extreme concentration range. This is relevant in the equine species, where SAA concentrations may reach very high concentrations.


2019 ◽  
Author(s):  
Stine Jacobsen ◽  
Anne Mette Vinther ◽  
Mads Kjelgaard-Hansen ◽  
Lise Nikolic Nielsen

Abstract Background Serum amyloid A (SAA) is a major equine acute phase protein and of great value in detection and monitoring of inflammation. A new immunoturbidometric assay based on monoclonal antibodies (VET-SAA, Eiken Chemical Co., Japan) may be useful for SAA measurements in routine diagnostic laboratories. The aim of the study was to validate the VET-SAA immunoturbidometric assay and use it to measure serum SAA concentrations in a variety of clinical cases. Precision was assessed by intra- and interassay coefficients of variation of repeated measurements of serum pools (low, intermediate, high concentrations of SAA). Accuracy was estimated by linearity under dilution. Detection limit was determined by replicate determinations of ionized water. Measurements were compared to measurements performed in a previously validated SAA assay (LZSAA assay, Eiken Chemical Co., Japan). Subsequently, the VET-SAA assay was used for measuring serum SAA concentrations in horses with and without inflammation. Results Detection limit was 1.2 mg/L. Without modifications, the assay measured SAA concentrations with acceptable reliability in a broad concentration range (0 to > 6000 mg/L). In the 0-3000 mg/L range, the assay demonstrated good precision and accuracy, and concentrations correlated well with those obtained in the LZSAA assay, albeit with a slight systematic bias. Concentrations of SAA assessed in horses with and without inflammation followed the expected pattern, with significantly higher concentrations in horses with systemic inflammation than in healthy horses and horses with non-inflammatory disease. Conclusions The assay was unique in its ability to measure SAA concentrations with acceptable reliability over an extreme concentration range. This is relevant in the equine species, where SAA concentrations may reach very high concentrations.


2019 ◽  
Author(s):  
Stine Jacobsen ◽  
Anne Mette Vinther ◽  
Mads Kjelgaard-Hansen ◽  
Lise Nikolic Nielsen

Abstract Background Serum amyloid A (SAA) is a major equine acute phase protein and of great value in detection and monitoring of inflammation. A new immunoturbidometric assay based on monoclonal antibodies (VET-SAA, Eiken Chemical Co., Japan) may be useful for SAA measurements in routine diagnostic laboratories. The aim of the study was to validate the VET-SAA immunoturbidometric assay and use it to measure serum SAA concentrations in a variety of clinical cases. Precision was assessed by intra- and interassay coefficients of variation of repeated measurements of serum pools (low, intermediate, high concentrations of SAA). Accuracy was estimated by linearity under dilution. Detection limit was determined by replicate determinations of ionized water. Measurements were compared to measurements performed in a previously validated SAA assay (LZSAA assay, Eiken Chemical Co., Japan). Subsequently, the VET-SAA assay was used for measuring serum SAA concentrations in horses with and without inflammation. Results Detection limit was 1.2 mg/L. Without modifications, the assay measured SAA concentrations with acceptable reliability in a broad concentration range (0 to > 6000 mg/L). In the 0-3000 mg/L range, the assay demonstrated good precision and accuracy, and concentrations correlated well with those obtained in the LZSAA assay, albeit with a slight systematic bias. Concentrations of SAA assessed in horses with and without inflammation followed the expected pattern, with significantly higher concentrations in horses with systemic inflammation than in healthy horses and horses with non-inflammatory disease. Conclusions The assay was unique in its ability to measure SAA concentrations with acceptable reliability over an extreme concentration range. This is relevant in the equine species, where SAA concentrations may reach very high concentrations.


2016 ◽  
Vol 54 (8) ◽  
pp. 1984-1991 ◽  
Author(s):  
Christen M. Gray ◽  
Achilles Katamba ◽  
Pratibha Narang ◽  
Jorge Giraldo ◽  
Carlos Zamudio ◽  
...  

Currently available nucleic acid amplification platforms for tuberculosis (TB) detection are not designed to be simple or inexpensive enough to implement in decentralized settings in countries with a high burden of disease. The loop-mediated isothermal amplification platform (LAMP) may change this. We conducted a study in adults with symptoms suggestive of TB in India, Uganda, and Peru to establish the feasibility of using TB-LAMP (Eiken Chemical Co.) in microscopy laboratories compared with using smear microscopy against a reference standard of solid and liquid cultures. Operational characteristics were evaluated as well. A total of 1,777 participants met the eligibility criteria and were included for analysis. Overall, TB-LAMP sensitivities among culture-positive samples were 97.2% (243/250; 95% confidence interval [CI], 94.3% to 98.2%) and 62.0% (88/142; 95% CI, 53.5% to 70.0%) for smear-positive and smear-negative TB, respectively, but varied widely by country and operator. Specificities ranged from 94.5% (446/472; 95% CI, 92.0% to 96.4%) to 98.0% (350/357; 95% CI, 96.0% to 99.2%) by country. A root cause analysis identified high temperatures, high humidity, and/or low reaction volumes as possible causes for false-positive results, as they may result in nonspecific amplification. The study was repeated in India with training focused on vulnerable steps and an updated protocol; 580 participants were included for analysis. Specificity in the repeat trial was 96.6% (515/533; 95% CI, 94.7% to 97.9%). To achieve acceptable performance of LAMP at the microscopy center level, significant training and infrastructure requirements are necessary.