Wearable Technologies
Latest Publications


TOTAL DOCUMENTS

28
(FIVE YEARS 28)

H-INDEX

1
(FIVE YEARS 1)

Published By Cambridge University Press (CUP)

2631-7176

2022 ◽  
Vol 3 ◽  
Author(s):  
W. Brandon Martin ◽  
Alexander Boehler ◽  
Kevin W. Hollander ◽  
Darren Kinney ◽  
Joseph K. Hitt ◽  
...  

Abstract Back pain is one of the largest drivers of workplace injury and lost productivity in industries around the world. Back injuries were one of the leading reasons in resulting in days away from work at 38.5% across all occupations, increasing for manual laborers to 43%. While the cause of the back pain can vary across occupations, for materiel movers it is often caused from repetitive poor lifting. To reduce the issues, the Aerial Porter Exoskeleton (APEx) was created. The APEx uses a hip-mounted, powered exoskeleton attached to an adjustable vest. An onboard computer calculates the configuration of the user to determine when to activate. Lift form is assisted by using a novel lumbar brace mounted on the sides of the hips. Properly worn, the APEx holds the user upright while providing additional hip torque through a lift. This was tested by having participants complete a lifting test with the exoskeleton worn in the “on” configuration compared with the exoskeleton not worn. The APEx has been shown to deliver 30 Nm of torque in lab testing. The activity recognition algorithm has also been shown to be accurate in 95% of tested conditions. When worn by subjects, testing has shown average peak reductions of 14.9% BPM, 8% in VO2 consumption, and an 8% change in perceived effort favoring the APEx.


2021 ◽  
Vol 2 ◽  
Author(s):  
Ryan Alicea ◽  
Michele Xiloyannis ◽  
Domenico Chiaradia ◽  
Michele Barsotti ◽  
Antonio Frisoli ◽  
...  

Abstract This paper presents a soft, tendon-driven, robotic glove designed to augment grasp capability and provide rehabilitation assistance for postspinal cord injury patients. The basis of the design is an underactuation approach utilizing postural synergies of the hand to support a large variety of grasps with a single actuator. The glove is lightweight, easy to don, and generates sufficient hand closing force to assist with activities of daily living. Device efficiency was examined through a characterization of the power transmission elements, and output force production was observed to be linear in both cylindrical and pinch grasp configurations. We further show that, as a result of the synergy-inspired actuation strategy, the glove only slightly alters the distribution of forces across the fingers, compared to a natural, unassisted grasping pattern. Finally, a preliminary case study was conducted using a participant suffering from an incomplete spinal cord injury (C7). It was found that through the use of the glove, the participant was able to achieve a 50% performance improvement (from four to six blocks) in a standard Box and Block test.


2021 ◽  
Vol 2 ◽  
Author(s):  
Rand Hidayah ◽  
Dongbao Sui ◽  
Kennedi A. Wade ◽  
Biing-Chwen Chang ◽  
Sunil Agrawal

Abstract Passive wearable exoskeletons are desirable as they can provide assistance during user movements while still maintaining a simple and low-profile design. These can be useful in industrial tasks where an ergonomic device could aid in load lifting without inconveniencing them and reducing fatigue and stress in the lower limbs. The SpringExo is a coil-spring design that aids in knee extension. In this paper, we describe the muscle activation of the knee flexors and extensors from seven healthy participants during repeated squats. The outcome measures are the timings of the key events during squat, flexion angle, muscle activation of rectus femoris and bicep femoris, and foot pressure characteristics of the participants. These outcome measures assess the possible effects of the device during lifting operations where reduced effort in the muscles is desired during ascent phase of the squat, without changing the knee and foot kinematics. The results show that the SpringExo significantly decreased rectus femoris activation during ascent (−2%) without significantly affecting either the bicep femoris or rectus femoris muscle activations in descent. This implies that the user could perform a descent without added effort and ascent with reduced effort. The exoskeleton showed other effects on the biomechanics of the user, increasing average squat time (+0.02 s) and maximum squat time (+0.1 s), and decreasing average knee flexion angle (−4°). The exoskeleton has no effect on foot loading or placement, that is, the user did not have to revise their stance while using the device.


2021 ◽  
Vol 2 ◽  
Author(s):  
Erik P. Lamers ◽  
Karl E. Zelik

Abstract Occupational exoskeletons and exosuits have been shown to reduce muscle demands and fatigue for physical tasks relevant to a variety of industries (e.g., logistics, construction, manufacturing, military, healthcare). However, adoption of these devices into the workforce has been slowed by practical factors related to comfort, form-factor, weight, and not interfering with movement or posture. We previously introduced a low-profile, dual-mode exosuit comprised of textile and elastic materials to address these adoption barriers. Here we build upon this prior work by introducing an extension mechanism that increases the moment arm of the exosuit while in engaged mode, then collapses in disengaged mode to retain key benefits related to being lightweight, low-profile, and unobstructive. Here we demonstrate both analytically and empirically how this extensible exosuit concept can (a) reduce device-to-body forces (which can improve comfort for some users and situations), or (b) increase the magnitude of torque assistance about the low back (which may be valuable for heavy-lifting jobs) without increasing shoulder or leg forces relative to the prior form-fitting exosuit. We also introduce a novel mode-switching mechanism, as well as a human-exosuit biomechanical model to elucidate how individual design parameters affect exosuit assistance torque and device-to-body forces. The proof-of-concept prototype, case study, and modeling work provide a foundation for understanding and implementing extensible exosuits for a broad range of applications. We envision promising opportunities to apply this new dual-mode extensible exosuit concept to assist heavy-lifting, to further enhance user comfort, and to address the unique needs of last-mile and other delivery workers.


2021 ◽  
Vol 2 ◽  
Author(s):  
Simona Crea ◽  
Philipp Beckerle ◽  
Michiel De Looze ◽  
Kevin De Pauw ◽  
Lorenzo Grazi ◽  
...  

Abstract The large-scale adoption of occupational exoskeletons (OEs) will only happen if clear evidence of effectiveness of the devices is available. Performing product-specific field validation studies would allow the stakeholders and decision-makers (e.g., employers, ergonomists, health, and safety departments) to assess OEs’ effectiveness in their specific work contexts and with experienced workers, who could further provide useful insights on practical issues related to exoskeleton daily use. This paper reviews present-day scientific methods for assessing the effectiveness of OEs in laboratory and field studies, and presents the vision of the authors on a roadmap that could lead to large-scale adoption of this technology. The analysis of the state-of-the-art shows methodological differences between laboratory and field studies. While the former are more extensively reported in scientific papers, they exhibit limited generalizability of the findings to real-world scenarios. On the contrary, field studies are limited in sample sizes and frequently focused only on subjective metrics. We propose a roadmap to promote large-scale knowledge-based adoption of OEs. It details that the analysis of the costs and benefits of this technology should be communicated to all stakeholders to facilitate informed decision making, so that each stakeholder can develop their specific role regarding this innovation. Large-scale field studies can help identify and monitor the possible side-effects related to exoskeleton use in real work situations, as well as provide a comprehensive scientific knowledge base to support the revision of ergonomics risk-assessment methods, safety standards and regulations, and the definition of guidelines and practices for the selection and use of OEs.


2021 ◽  
Vol 2 ◽  
Author(s):  
Sandra M. Siedl ◽  
Martina Mara

Abstract Objective This field study aimed to explore the effects of exoskeleton use on task-specific self-efficacy beliefs of logistics workers and to relate these effects to usefulness perceptions and technology acceptance. Background A growing number of industrial companies have shown interest in having employees wearing exoskeletons to support their physical health. However, psychological consequences of exoskeleton use and mechanisms associated with workers’ acceptance or rejection of exoskeletons are not yet sufficiently understood. Methods A total of 31 logistics workers of a vehicle manufacturing company reported on their work-related self-efficacy, that is, how capable they felt of performing tasks related to their job well, before partaking in half-hour trials of a passive lift-assistive exoskeleton (Laevo V2.5) during their normal work. Afterward, they completed a questionnaire on their exoskeleton-supported self-efficacy and indicated how useful they found the exoskeleton, how much physical relief they felt from wearing it, and how willing they were to continue with its use. Results Overall, wearing the exoskeleton did not lead to increased work-specific self-efficacy. However, indications of interaction effects were found between baseline self-efficacy, perceived physical relief, and perceived usefulness in such a way that workers who experienced the exoskeleton as more strain-relieving or more useful were also more likely to report a post-trial growth in their self-efficacy beliefs. A positive change in self-efficacy, in turn, was associated with a greater willingness to further use the exoskeleton at the workplace.


2021 ◽  
Vol 2 ◽  
Author(s):  
Patrick W. Franks ◽  
Gwendolyn M. Bryan ◽  
Russell M. Martin ◽  
Ricardo Reyes ◽  
Ava C. Lakmazaheri ◽  
...  

Abstract Exoskeletons that assist the hip, knee, and ankle joints have begun to improve human mobility, particularly by reducing the metabolic cost of walking. However, direct comparisons of optimal assistance of these joints, or their combinations, have not yet been possible. Assisting multiple joints may be more beneficial than the sum of individual effects, because muscles often span multiple joints, or less effective, because single-joint assistance can indirectly aid other joints. In this study, we used a hip–knee–ankle exoskeleton emulator paired with human-in-the-loop optimization to find single-joint, two-joint, and whole-leg assistance that maximally reduced the metabolic cost of walking. Hip-only and ankle-only assistance reduced the metabolic cost of walking by 26 and 30% relative to walking in the device unassisted, confirming that both joints are good targets for assistance (N = 3). Knee-only assistance reduced the metabolic cost of walking by 13%, demonstrating that effective knee assistance is possible (N = 3). Two-joint assistance reduced the metabolic cost of walking by between 33 and 42%, with the largest improvements coming from hip-ankle assistance (N = 3). Assisting all three joints reduced the metabolic cost of walking by 50%, showing that at least half of the metabolic energy expended during walking can be saved through exoskeleton assistance (N = 4). Changes in kinematics and muscle activity indicate that single-joint assistance indirectly assisted muscles at other joints, such that the improvement from whole-leg assistance was smaller than the sum of its single-joint parts. Exoskeletons can assist the entire limb for maximum effect, but a single well-chosen joint can be more efficient when considering additional factors such as weight and cost.


2021 ◽  
Vol 2 ◽  
Author(s):  
Hashim A. Quraishi ◽  
Max K. Shepherd ◽  
Leo McManus ◽  
Jaap Harlaar ◽  
Dick H. Plettenburg ◽  
...  

Abstract Individuals with lower limb amputation experience reduced ankle push-off work in the absence of functional muscles spanning the joint, leading to decreased walking performance. Conventional energy storage and return (ESR) prostheses partially compensate by storing mechanical energy during midstance and returning this energy during the terminal stance phase of gait. These prostheses can provide approximately 30% of the push-off work performed by a healthy ankle–foot during walking. Novel prostheses that return more normative levels of mechanical energy may improve walking performance. In this work, we designed a Decoupled ESR (DESR) prosthesis which stores energy usually dissipated at heel-strike and loading response, and returns this energy during terminal stance, thus increasing the mechanical push-off work done by the prosthesis. This decoupling is achieved by switching between two different cam profiles that produce distinct, nonlinear torque–angle mechanics. The cams automatically interchange at key points in the gait cycle via a custom magnetic switching system. Benchtop characterization demonstrated the successful decoupling of energy storage and return. The DESR mechanism was able to capture energy at heel-strike and loading response, and return it later in the gait cycle, but this recycling was not sufficient to overcome mechanical losses. In addition to its potential for recycling energy, the DESR mechanism also enables unique mechanical customizability, such as dorsiflexion during swing phase for toe clearance, or increasing the rate of energy release at push-off.


2021 ◽  
Vol 2 ◽  
Author(s):  
Annemarijn Steijlen ◽  
Bastiaan Burgers ◽  
Erik Wilmes ◽  
Jeroen Bastemeijer ◽  
Bram Bastiaansen ◽  
...  

Abstract This article presents a novel smart sensor garment with integrated miniaturized inertial measurements units (IMUs) that can be used to monitor lower body kinematics during daily training activities, without the need of extensive technical assistance throughout the measurements. The smart sensor tights enclose five ultra-light sensor modules that measure linear accelerations, angular velocities, and the earth magnetic field in three directions. The modules are located at the pelvis, thighs, and shanks. The garment enables continuous measurement in the field at high sample rates (250 Hz) and the sensors have a large measurement range (32 g, 4,000°/s). They are read out by a central processing unit through an SPI bus, and connected to a centralized battery in the waistband. A fully functioning prototype was built to perform validation studies in a lab setting and in a field setting. In the lab validation study, the IMU data (converted to limb orientation data) were compared with the kinematic data of an optoelectronic measurement system and good validity (CMCs >0.8) was shown. In the field tests, participants experienced the tights as comfortable to wear and they did not feel restricted in their movements. These results show the potential of using the smart sensor tights on a regular base to derive lower limb kinematics in the field.


2021 ◽  
Vol 2 ◽  
Author(s):  
Jo Ghillebert ◽  
Joost Geeroms ◽  
Louis Flynn ◽  
Sander De Bock ◽  
Renée Govaerts ◽  
...  

Abstract Background The CYBERLEGs-gamma (CLs-ɣ) prosthesis has been developed to investigate the possibilities of powerful active prosthetics in restoring human gait capabilities after lower limb amputation. Objective The objective of this study was to determine the performance of the CLs-ɣ prosthesis during simulated daily activities. Methods Eight participants with a transfemoral amputation (age: 55 ± 15 years, K-level 3, registered under: NCT03376919) performed a familiarization session, an experimental session with their current prosthesis, three training sessions with the CLs-ɣ prosthesis and another experimental session with the CLs-ɣ prosthesis. Participants completed a stair-climbing-test, a timed-up-and-go-test, a sit-to stand-test, a 2-min dual-task and a 6-min treadmill walk test. Results Comparisons between the two experimental sessions showed that stride length significantly increased during walking with the CLs-ɣ prosthesis (p = .012) due to a greater step length of the amputated leg (p = .035). Although a training period with the prototype was included, preferred walking speed was significantly slower (p = .018), the metabolic cost of transport was significantly higher (p = .028) and reaction times significantly worsened (p = .012) when walking with the CLs-ɣ compared to the current prosthesis. Conclusions It can be stated that a higher physical and cognitive effort were required when wearing the CLs-ɣ prosthesis. Positive outcomes were observed regarding stride length and stair ambulation. Future prosthetics development should minimize the weight of the device and integrate customized control systems. A recommendation for future research is to include several shorter training periods or a prolonged adaptation period.


Sign in / Sign up

Export Citation Format

Share Document