scholarly journals THE IRON CONTENT OF THE WHOLE BLOOD OF NORMAL INDIVIDUALS

1934 ◽  
Vol 104 (1) ◽  
pp. 157-161
Author(s):  
O.M. Helmer ◽  
Charles P. Emerson
1927 ◽  
Vol 46 (1) ◽  
pp. 43-51
Author(s):  
Blake C. Wilbur ◽  
Geneva A. Daland ◽  
John Cohen

A description is given of a closed space respiration apparatus which can be used to determine the amount of gas used or liberated by living blood or tissue cells, or chemical substances. Continuous observations can be made and repeated measurements recorded without interrupting the vital processes or destroying the cells. Studies of the oxygen consumption by whole blood in normal individuals and in patients with leucocytosis and myelogenous leucemia, as well as by white cells suspended in plasma, will be reported in subsequent papers.


Blood ◽  
1985 ◽  
Vol 65 (2) ◽  
pp. 433-440
Author(s):  
RL Roberts ◽  
JI Gallin

Previous studies on human eosinophils often have used cells from patients with hypereosinophilia syndrome or parasitosis owing to the difficulty in isolating pure populations of eosinophils from normal individuals. In the present study, human eosinophils were isolated with a purity of 97%, with 70% recovery from normal individuals with blood eosinophil counts of less than 3%. Human eosinophils are denser than neutrophils, but the range of densities of the two cell types overlap, making purification of eosinophils by density-gradient centrifugation difficult. However, if neutrophils were exposed to the chemotactic peptide (f-Met-Leu-Phe), which did not stimulate eosinophils, the neutrophils' density decreased, shifting them away from the density of eosinophils. Whole normal blood anticoagulated with EDTA was incubated at 37 degrees C for 15 minutes with 10(-6) mol/L f-Met-Leu-Phe and then layered over a discontinuous Percoll gradient (65% and 75% in diluted phosphate-buffered saline) and centrifuged at 400 g for 25 minutes at 22 degrees C. The cell layer between the 65% and 75% Percoll was collected and washed, and hypotonic lysis was used to remove erythrocytes. This cell layer contained 97.3 +/- 0.7% eosinophils (N = 8) with a yield of 4.9 X 10(4) eosinophils per milliliter of whole blood, or 70% of the total eosinophil count. The isolated eosinophils were in a quiescent state but responded to Escherichia coli endotoxin- activated serum with shape change and chemotaxis, membrane depolarization, and reduced nitroblue tetrazolium (96.0 +/- 1.0%), when stimulated with phorbol myristate acetate. In phagocytic assays, 89.3 +/- 1.3% of the eosinophils ingested Candida albicans v 96.0% +/- 1.0% of neutrophils. In contrast, the eosinophils did not respond chemotactically, alter membrane potential, or reduce nitroblue tetrazolium when treated with f-Met-Leu-Phe, and studies with f-Met-Leu- [3H]Phe showed that normal eosinophils lacked expression of receptors for f-Met-Leu-Phe. In control studies, normal eosinophils that were not exposed to f-Met-Leu-Phe during purification also failed to respond to f-Met-Leu-Phe, indicating intrinsic differences between normal eosinophils and neutrophils. Thus, exposure of whole blood to f-Met-Leu- Phe, followed by separation on Percoll is a simple method for rapid isolation of normal human eosinophils.


Blood ◽  
1985 ◽  
Vol 65 (2) ◽  
pp. 433-440 ◽  
Author(s):  
RL Roberts ◽  
JI Gallin

Abstract Previous studies on human eosinophils often have used cells from patients with hypereosinophilia syndrome or parasitosis owing to the difficulty in isolating pure populations of eosinophils from normal individuals. In the present study, human eosinophils were isolated with a purity of 97%, with 70% recovery from normal individuals with blood eosinophil counts of less than 3%. Human eosinophils are denser than neutrophils, but the range of densities of the two cell types overlap, making purification of eosinophils by density-gradient centrifugation difficult. However, if neutrophils were exposed to the chemotactic peptide (f-Met-Leu-Phe), which did not stimulate eosinophils, the neutrophils' density decreased, shifting them away from the density of eosinophils. Whole normal blood anticoagulated with EDTA was incubated at 37 degrees C for 15 minutes with 10(-6) mol/L f-Met-Leu-Phe and then layered over a discontinuous Percoll gradient (65% and 75% in diluted phosphate-buffered saline) and centrifuged at 400 g for 25 minutes at 22 degrees C. The cell layer between the 65% and 75% Percoll was collected and washed, and hypotonic lysis was used to remove erythrocytes. This cell layer contained 97.3 +/- 0.7% eosinophils (N = 8) with a yield of 4.9 X 10(4) eosinophils per milliliter of whole blood, or 70% of the total eosinophil count. The isolated eosinophils were in a quiescent state but responded to Escherichia coli endotoxin- activated serum with shape change and chemotaxis, membrane depolarization, and reduced nitroblue tetrazolium (96.0 +/- 1.0%), when stimulated with phorbol myristate acetate. In phagocytic assays, 89.3 +/- 1.3% of the eosinophils ingested Candida albicans v 96.0% +/- 1.0% of neutrophils. In contrast, the eosinophils did not respond chemotactically, alter membrane potential, or reduce nitroblue tetrazolium when treated with f-Met-Leu-Phe, and studies with f-Met-Leu- [3H]Phe showed that normal eosinophils lacked expression of receptors for f-Met-Leu-Phe. In control studies, normal eosinophils that were not exposed to f-Met-Leu-Phe during purification also failed to respond to f-Met-Leu-Phe, indicating intrinsic differences between normal eosinophils and neutrophils. Thus, exposure of whole blood to f-Met-Leu- Phe, followed by separation on Percoll is a simple method for rapid isolation of normal human eosinophils.


Blood ◽  
1983 ◽  
Vol 61 (3) ◽  
pp. 449-455 ◽  
Author(s):  
SJ Knox ◽  
BR Greenberg ◽  
RW Anderson ◽  
LS Rosenblatt

Abstract Tritiated thymidine incorporation in a whole blood lymphocyte stimulation test (LST) and lymphocyte colony formation (CFU-L) from whole blood were measured following in vitro x-irradiation. Lymphocytes from patients with myelodysplastic disorders, acute nonlymphocytic leukemia, and patients at increased risk for leukemia because of their primary disease and/or cytotoxic therapy were found to be significantly more sensitive to in vitro x-irradiation than lymphocytes from clinically normal individuals. Cloning efficiencies and mitogenic responsiveness of patient lymphocytes were significantly depressed as compared to normal values. Using monoclonal antibodies to specific surface markers, quantitative abnormalities in lymphocytic subpopulations from myelodysplastic patients also were observed. These findings are suggestive of a defect at the T-cell level that may directly or indirectly affect hematopoiesis.


1977 ◽  
Author(s):  
J.A. Caprini ◽  
L. Zuckerman ◽  
E. Cohen ◽  
J.P. Vagher ◽  
V. Lipp

This report describes a new method for comparing overall clotting characteristics between normal individuals and those with proven malignancy using thrombelastographic (TEG) comparison of native and celite-activated specimens. Native whole blood TEG, celite-activated TEG, and standard coagulation tests were performed on the same blood collection in 90 normals and 90 patients with new malignancies and the results were used to derive a discriminate equation This equation classified correctly all 90 normals and 88 out of 90 cancer patients. The formulation was verified with an additional 82 patients with only one incorrect classification in the 31 cancer subjects. The standard coagulation tests did not discriminate without significant overlap between cancer patients and normals. The high degree of discrimination obtained with our TEG analysis provides a new tool to compare individual clotting differences that may have important clinical applications. However, the results cannot be extrapolated to selectively identify those with malignancy among the general population since many other stimuli may produce accelerated coagulability. This analysis does provide identification of accelerated coagulability in association with new malignancies.


Blood ◽  
2004 ◽  
Vol 104 (11) ◽  
pp. 3901-3901
Author(s):  
Rachelle Blain ◽  
Peggy Nakagawa ◽  
Thomas Kunicki ◽  
Melissa Belvedere ◽  
Diane Nugent

Abstract In large studies of patients with cardiac disease, it was observed that up to 9% are ASA resistant (ASAR) and 23% are ASA semi responders using the platelet function analyzer (PFA-100), which measures whole blood platelet adhesion and aggregation under high shear. The prevalence of ASAR is of great clinical importance. With an estimated 20 million patients in the USA taking ASA for prevention of atherosclerotic events, even a 10% incidence equates to more than two million patients receiving inadequate anti-platelet therapy. Given the widespread use of ASA, more reliable and rapid methods to measure aspirin sensitivity are needed. Importantly, future large scale studies to determine the effect of monitoring ASA sensitivity to optimize therapy are compromised due to current lack of uniformity in assessing ASAR from center to center. The classical method of platelet aggregometry is labor-intensive and not readily adaptable to the clinical setting. Moreover, platelet aggregometry measures platelet responses under low shear, which does not simulate the high shear conditions expected to be involved in arterial thrombosis. In contrast, the PFA-100 does measure thrombus formation under high shear. The new TEG platelet coagulation assay uses whole blood, includes high shear, and is a point of care method. We compared these three techniques to assess aspirin effects on platelet function and clot formation: PFA-100 with collagen-epinephrine cartridges, TEG platelet coagulation assay, and standard optical aggregation in platelet rich plasma using arachidonic acid (AA) and adenosine diphosphate (ADP) as agonists. RESULTS: We found significant differences between the PFA-100, TEG platelet function, and standard optical aggregation. Twelve normal individuals previously defined as ASA sensitive or ASAR, using the PFA-100, were studied at baseline and following three days of oral aspirin at 81mg/day. We found that all four patients determined to be ASAR by PFA-100 were found to be sensitive in TEG and aggregometer assays when using AA as the agonist. Furthermore, some participants showed a gain of platelet function following ASA when studied on the TEG and aggregometer using ADP as the agonist. Currently, it is unclear which response to ASA treatment is most important to predict cardiovascular complications in normal individuals or patients placed on aspirin. Gum et al, showed that increased urinary secrection of thromboxane metabolites, suggesting ASA insensitivity, is associated with a higher incidence of cardiovascular events. Unfortunately, this test may simply indicate poor patient compliance rather than true ASAR, so a clear demonstration of platelet sensitivity will also be necessary. Our data confirms the need for a collaborative trial comparing different platelet assays to assess true ASA sensitivity together with concurrent measurements of urinary thromboxane metabolite levels. Knowing which assay best links aspirin sensitivity to disease outcome will allow physicians to better manage normal individuals and patients at risk for significant cardiovascular disease.


2016 ◽  
Vol 43 (1) ◽  
pp. 32-38 ◽  
Author(s):  
Tatsuo Tsukamoto ◽  
Takayuki Matsubara ◽  
Yuka Akashi ◽  
Morihiro Kondo ◽  
Motoko Yanagita

Background: In order to keep up the optimal iron status in chronic hemodialysis patients, it is important to know how much iron is lost due to hemodialysis. Residual blood associated with the hemodialysis procedure together with blood sampling inevitably causes the loss of iron in chronic hemodialysis patients. Recent advances in hemodialysis techniques might have reduced this complication. In this cross-sectional study, we directly measured total iron loss by hemodialysis. Methods: Two hundred thirty-nine patients who received chronic hemodialysis at Otowa Memorial Hospital were enrolled; 65.7% of patients were men, and mean age was 67 ± 6.4 years (mean ± SD) and 43.2% were diabetic. Residual blood in blood tubing set and dialyzer after rinse back with saline was collected and homogenized. The iron content including free, protein-bound and heme iron was measured using an atomic absorption spectrometry. Results: The mean iron content in residual blood was 1,247.3 ± 796.2 µg (mean ± SD) and the median was 1,002 µg (95% CI 377.6-3,461.6 µg), indicating 160.8 mg (95% CI 58.9-540.0 mg) iron loss annually when hemodialysis was performed 156 times a year. Fifty milliliter whole blood for monthly blood test and another 2 ml of whole blood lost by paracentesis at every dialysis session contains 228.6 and 118.9 mg iron at 11 g/dl hemoglobin, respectively. Therefore, an annual total iron loss due to hemodialysis comes to 508.3 mg (95% CI 406.4-887.5 mg). Conclusions: Five hundred milligram of annual iron supplementation might be sufficient to maintain iron status in hemodialysis patients, which is less than the dose recommended as 1,000-2,000 mg a year. Further study will be required to verify this iron supplementation dosage with recent hemodialysis procedure.


Cytokine ◽  
2003 ◽  
Vol 24 (6) ◽  
pp. 286-292 ◽  
Author(s):  
Pavlos Myrianthefs ◽  
Stylianos Karatzas ◽  
Kyriaki Venetsanou ◽  
Elisabeth Grouzi ◽  
Penelope Evagelopoulou ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document