Effect of Glove Liners on Sweat Rate, Comfort, and Psychomotor Task Performance

1988 ◽  
Vol 58 (3) ◽  
pp. 166-173 ◽  
Author(s):  
Donna H. Branson ◽  
Lynda Abusamra ◽  
Carolyn Hoener ◽  
Sandra Rice

Military subjects participated in a study to evaluate four glove liners worn beneath chemical protective gloves, with regard to sweating of the hands, manual dexterity performance, and perceived comfort in a moderate thermal environment. Although there was a trend for subjects wearing the standard Army liner to experience the lowest sweat rate, the liner effect was not significant due to individual variation. No liner differences were found for manual dexterity performance, hand skin temperature, perceived temperature, and thermal comfort. Differences by liner were found for tactile descriptors used to assess liner comfort. Skin temperature, perceived temperature, and perceived thermal discomfort increased over the duration of the two-hour test, regardless of the liner worn.

2019 ◽  
Vol 9 (5) ◽  
pp. 899 ◽  
Author(s):  
Jongseong Gwak ◽  
Motoki Shino ◽  
Kazutaka Ueda ◽  
Minoru Kamata

Thermal factors not only affect the thermal comfort sensation of occupants, but also affect their arousal level, productivity, and health. Therefore, it is necessary to control thermal factors appropriately. In this study, we aim to design a thermal environment that improves both the arousal level and thermal comfort of the occupants. To this end, we investigated the relationships between the physiological indices, subjective evaluation values, and task performance under several conditions of changes in the indoor ambient temperature. In particular, we asked subjects to perform a mathematical task and subjective evaluation related to their thermal comfort sensation and drowsiness levels. Simultaneously, we measured their physiological parameters, such as skin temperature, respiration rate, electroencephalography, and electrocardiography, continuously. We investigated the relationship between the comfort sensation and drowsiness level of occupants, and the physiological indices. From the results, it was confirmed that changes in the indoor ambient temperature can improve both the thermal comfort and the arousal levels of occupants. Moreover, we proposed the evaluation indices of the thermal comfort and the drowsiness level of occupants using physiological indices.


Atmosphere ◽  
2020 ◽  
Vol 11 (10) ◽  
pp. 1101
Author(s):  
Si-Yu Yu ◽  
Andreas Matzarakis ◽  
Tzu-Ping Lin

It is quite difficult to investigate thermal comfort in hot–humid regions, and there have not been many real case studies or research related to this issue. In this article, four running events held in nearby popular travel spots in Kaohsiung, the largest city in southern Taiwan, were selected to analyze the influence of thermal environment and air quality on thermal comfort. Mostly real time environmental monitoring data were applied for estimating thermal indicators, along with Sky View Factor (SVF) data taken at the sites of the running scheduled routes, to analyze the thermal performance of participants at running events. Compared with runners, walkers (local residents, fans, and staff of the events) would be exposed to a greater risk of thermal discomfort with increasing time spent on the routes. With the integrated analysis, mPET (modified physiologically equivalent temperature) can be viewed as a relatively comprehensive indicator in considering both environmental thermal conditions and the biometrical differences of activities and clothing types. From the results, a good correlation between mPET and solar radiation/SVF was obtained, which indicated that mPET could be sufficiently sensible in revealing the thermal condition variation from one site to another during the route with time. Based on the discomfort risk assessment, for runners, the event held in autumn with lower SVF at the route sites would be less risky of thermal discomfort, while the event held in spring with lower solar radiation would be more comfortable for walkers. As for air quality condition, the inappropriateness of holding winter outdoor activities in Kaohsiung was obviously shown in both real time monitoring data and long term analysis.


Author(s):  
Nicole T. Vargas ◽  
Christopher L. Chapman ◽  
Blair D. Johnson ◽  
Rob Gathercole ◽  
Matthew N. Cramer ◽  
...  

We tested the hypothesis that thermal behavior alleviates thermal discomfort and accelerates core temperature recovery following low intensity exercise. Methods: In a 27 ± 0 °C, 48 ± 6% relative humidity environment, 12 healthy subjects (six females) completed 60 min of exercise followed by 90 min of seated recovery on two occasions. Subjects wore a suit top perfusing 34 ± 0 °C water during exercise. In the control trial, this water continually perfused throughout recovery. In the behavior trial, the upper body was maintained thermally comfortable by pressing a button to receive cool water (3 ± 2 °C) perfusing through the top for 2 min per button press. Results: Physiological variables (core temperature, p ≥ 0.18; mean skin temperature, p = 0.99; skin wettedness, p ≥ 0.09; forearm skin blood flow, p = 0.29 and local axilla sweat rate, p = 0.99) did not differ between trials during exercise. Following exercise, mean skin temperature decreased in the behavior trial in the first 10 min (by −0.5 ± 0.7 °C, p < 0.01) and upper body skin temperature was reduced until 70 min into recovery (by 1.8 ± 1.4 °C, p < 0.05). Core temperature recovered to pre-exercise levels 17 ± 31 min faster (p = 0.02) in the behavior trial. There were no differences in skin blood flow or local sweat rate between conditions during recovery (p ≥ 0.05). Whole-body thermal discomfort was reduced (by −0.4 ± 0.5 a.u.) in the behavior trial compared to the control trial within the first 20 min of recovery (p ≤ 0.02). Thermal behavior via upper body cooling resulted in augmented cumulative heat loss within the first 30 min of recovery (Behavior: 288 ± 92 kJ; Control: 160 ± 44 kJ, p = 0.02). Conclusions: Engaging in thermal behavior that results in large reductions in mean skin temperature following exercise accelerates the recovery of core temperature and alleviates thermal discomfort by promoting heat loss.


2021 ◽  
pp. 004051752110265
Author(s):  
Miao Tian ◽  
Xianghui Zhang ◽  
Xumei Tang

Maintaining foot comfort is important as it influences the overall comfort of the human body. Shoe microclimate and foot skin temperature have been suggested to contribute to the thermal sensation of the foot. Considering the thermal environment and personal protective equipment (PPE) used for structural and proximity firefighting, climatic chamber tests with 13 male participants were conducted during standing and walking. Four test conditions – unloaded with training shoes, loaded with training shoes, unloaded with firefighting boots, and loaded with firefighting boots – were designed to investigate the effects of firefighting boots and PPE load on the thermal comfort of the human foot. Physiological variables of in-shoe and foot skin temperature at the whole and local regions of the foot were measured and subjective responses were gathered using psychological scales. The results showed that wearing firefighting boots may elevate the thermal sensation of wearers. The PPE load increased the in-shoe and foot skin temperature as well as subjective ratings. Subjective sensations of the foot were strongly correlated with in-shoe and skin temperature in the plantar regions. Correlation analysis of thermal sensation at the whole and local foot regions indicated that the sensation at the forefoot was closest to the whole foot, followed by the midfoot and heel. The findings address the relationship of physiological and subjective variables as well as the thermal sensation of whole and local foot regions, which can be considered for footwear design and thermal comfort prediction of the foot and whole body.


Author(s):  
Laura J. Elstub ◽  
Shimra J. Fine ◽  
Karl E. Zelik

Exoskeletons and exosuits (exos) are wearable devices that physically assist movement. User comfort is critically important for societal adoption of exos. Thermal comfort (a person’s satisfaction with their thermal environment) represents a key design challenge. Exos must physically attach/interface to the body to apply forces, and these interfaces inevitably trap some heat. It is envisioned that thermal comfort could be improved by designing mode-switching exo interfaces that temporarily loosen around a body segment when assistive forces are not being applied. To inform exo design, a case series study (N = 4) based on single-subject design principles was performed. Our objective was to assess individual responses to skin temperature and thermal comfort during physical activity with a Loose leg-sleeve interface compared with a Form-Fitting one, and immediately after a Form-Fitting sleeve switched to Loose. Skin under the Loose sleeve was 2–3 °C (4–6 °F) cooler after 25 min of physical activity, and two of four participants reported the Loose sleeve improved their thermal comfort. After completion of the physical activity, the Form-Fitting sleeve was loosened, causing a 2–4 °C (3–8 °F) drop in skin temperature underneath for all participants, and two participants to report slightly improved thermal comfort. These findings confirmed that an exo that can quickly loosen its interface when assistance is not required—and re-tighten when it is— has the potential to enhance thermal comfort for some individuals and environments. More broadly, this study demonstrates that mode-switching mechanisms in exos can do more than adjust physical assistance: they can also exploit thermodynamics and facilitate thermoregulation in a way that enhances comfort for exo users.


Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 244
Author(s):  
Ana Maria Bueno ◽  
Antonio Augusto de Paula Xavier ◽  
Evandro Eduardo Broday

The thermal environment is one of the main factors that influence thermal comfort and, consequently, the productivity of occupants inside buildings. Throughout the years, research has described the connection between thermal comfort and productivity. Mathematical models have been established in the attempt to predict changes in productivity according to thermal variations in the environment. Some of these models have failed for a number of reasons, including the understanding of the effect that several environment variables have had on performance. From this context, a systematic literature review was carried out with the aim of verifying the connection between thermal comfort and productivity and the combinations of different thermal and personal factors that can have an effect on productivity. A hundred and twenty-eight articles were found which show a connection between productivity and some thermal comfort variables. By means of specific inclusion and exclusion criteria, 60 articles were selected for a final analysis. The main conclusions found in this study were: (i) the vast majority of research uses subjective measures and/or a combination of methods to evaluate productivity; (ii) performance/productivity can be attained within an ampler temperature range; (iii) few studies present ways of calculating productivity.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 696
Author(s):  
Eun Ji Choi ◽  
Jin Woo Moon ◽  
Ji-hoon Han ◽  
Yongseok Yoo

The type of occupant activities is a significantly important factor to determine indoor thermal comfort; thus, an accurate method to estimate occupant activity needs to be developed. The purpose of this study was to develop a deep neural network (DNN) model for estimating the joint location of diverse human activities, which will be used to provide a comfortable thermal environment. The DNN model was trained with images to estimate 14 joints of a person performing 10 common indoor activities. The DNN contained numerous shortcut connections for efficient training and had two stages of sequential and parallel layers for accurate joint localization. Estimation accuracy was quantified using the mean squared error (MSE) for the estimated joints and the percentage of correct parts (PCP) for the body parts. The results show that the joint MSEs for the head and neck were lowest, and the PCP was highest for the torso. The PCP for individual activities ranged from 0.71 to 0.92, while typing and standing in a relaxed manner were the activities with the highest PCP. Estimation accuracy was higher for relatively still activities and lower for activities involving wide-ranging arm or leg motion. This study thus highlights the potential for the accurate estimation of occupant indoor activities by proposing a novel DNN model. This approach holds significant promise for finding the actual type of occupant activities and for use in target indoor applications related to thermal comfort in buildings.


Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4530
Author(s):  
Youcef Bouzidi ◽  
Zoubayre El Akili ◽  
Antoine Gademer ◽  
Nacef Tazi ◽  
Adil Chahboun

This paper investigates adaptive thermal comfort during summer in medical residences that are located in the French city of Troyes and managed by the Association of Parents of Disabled Children (APEI). Thermal comfort in these buildings is evaluated using subjective measurements and objective physical parameters. The thermal sensations of respondents were determined by questionnaires, while thermal comfort was estimated using the predicted mean vote (PMV) model. Indoor environmental parameters (relative humidity, mean radiant temperature, air temperature, and air velocity) were measured using a thermal environment sensor during the summer period in July and August 2018. A good correlation was found between operative temperature, mean radiant temperature, and PMV. The neutral temperature was determined by linear regression analysis of the operative temperature and Fanger’s PMV model. The obtained neutral temperature is 23.7 °C. Based on the datasets and questionnaires, the adaptive coefficient α representing patients’ capacity to adapt to heat was found to be 1.261. A strong correlation was also observed between the sequential thermal index n(t) and the adaptive temperature. Finally, a new empirical model of adaptive temperature was developed using the data collected from a longitudinal survey in four residential buildings of APEI in summer, and the obtained adaptive temperature is 25.0 °C with upper and lower limits of 24.7 °C and 25.4 °C.


Sign in / Sign up

Export Citation Format

Share Document