scholarly journals Comparative Analysis of the Shear Bond Strength of Flowable Self-Adhering Resin-Composites Adhesive to Dentin with a Conventional Adhesive

Coatings ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 273
Author(s):  
Abdulmajeed Ali Asiri ◽  
Rawaiz Khan ◽  
Sultan Saeed Alzahrani ◽  
Sajjad Haider ◽  
Salah Ud-Din Khan ◽  
...  

This study aimed to measure and compare the shear bond strength (SBS) of a self-adhering flowable resin composite to dentin with a conventional flowable composite, and evaluate the various modes of failure. Thirty human premolar teeth (n = 30) were randomly allocated to two groups (Group I: Vertise™ Flow; Group II: Filtek Ultimate + Single Bond Universal) of 15 specimens each, and SBS was measured for specimens from each group by applying a shear load using a universal testing machine (UTM). Modes of failure were observed with an optical microscope. An independent-samples T-test was performed to test Levene’s assumption of homogeneity of variance across both groups, with the critical value set at 0.05. The results revealed, that the self-adhering flowable composite (Group I: Vertise™ Flow) resulted in a lower shear bond strength compared with the conventional adhesive system composite (Group II: Filtek Ultimate + Single Bond Universal). Moreover, group I predominantly exhibited non-cohesive failure, which reflects poor bonding to dentin. On the other hand, Group II showed mixed failure for most of the samples, which demonstrated strong adhesive bonding. Therefore, it could be concluded that the self-adhering flowable resin composite (Group I) results in lower SBS to dentin compared with a conventional adhesive system.

Author(s):  
Asiri AA ◽  
◽  
Khan R ◽  
Alzahrani SS ◽  
Haider S ◽  
...  

This study aimed to measure and compare the Shear Bond Strength (SBS) of a self-adhering flowable resin composite to dentin with a conventional flowable composite, and evaluate the various modes of failure. Thirty (n=30) human premolar teeth were randomly allocated to two groups (Group I: Vertise Flow; Group II: Filtek Ultimate) of 15 specimens each, and SBS was measured for specimens from each group by applying shear load using a Universal Testing Machine (UTM). Modes of failure were observed with an optical microscope. An independent samples T test was performed to test the Levene’s assumption of homogeneity of variance across both groups, with the critical value set at 0.05. The results revealed, that the self-adhering flowable composite (Group I: VertiseTM Flow) resulted in lower shear bond strength as compared with the conventional flowable resin composite (Group II: Filtek Ultimate). Moreover, group I predominantly exhibited non-cohesive failure which reflects a poor bonding to dentin. On the other hand, Group II showed mixed failure for most of the samples, which demonstrate strong adhesive bonding. Therefore, it could be concluded that the self-adhering flowable resin composite (Group I) results in lower SBS to dentin as compare with conventional flowable composite.


2021 ◽  
Vol 23 (4) ◽  
pp. 277-281
Author(s):  
Rodrigo Galo ◽  
Isabela Maluta ◽  
Marta Maria Martins Giamatei Contente ◽  
Carolina Paes Torres ◽  
Maria Cristina Borsatto

AbstractIn the routine clinical situation, the contamination by blood and/or saliva in restorative procedures can be happen in non-cooperation of the patient in dental office. The aim of the study was to assess in vitro shear bond strength of a resin sealant associated with two types of adhesives contaminated with saliva and blood. Healthy human molars were used and the specimens and the crowns were sectioned in the bucco-lingual direction, thus obtaining two segments of similar proportions (mesial and distal), totaling 60 surfaces, and the surfaces were randomly divided into 4 groups (n = 15). Group I (control) received no type of contamination and the sealant was applied. In group II, the surfaces were contaminated with 10 μl of saliva/blood and the sealant was applied. In group III, the surfaces were contaminated with 10 μl of saliva/blood and the Single Bond total-etch adhesive system was applied followed by application of sealant. In group IV, the surfaces were contaminated with 10 μl of saliva/blood and the Prime & Bond NT total-etch adhesive system was applied followed by the application of sealant. Samples were tested in the universal testing machine and the analysis of shear bond strength was performed. A difference between Group I (12.61MPa) and the other groups was found; Group II (2. 28MPa) was different than Groups III (7.07MPa) and IV (7.79MPa), but Groups III and IV were similar. The application of an adhesive system when there is contamination with saliva/blood is required prior to application of pit and fissure sealants. Keywords: Pit and Fissure Sealants. Biological Contamination. Shear Strength. ResumoNa situação clínica de rotina, a contaminação por sangue e/ou saliva em procedimentos restauradores pode ocorrer em pacientes que não colaboram no consultório odontológico. O objetivo do estudo foi avaliar a resistência ao cisalhamento in vitro de um selante de resina associado a dois tipos de adesivos contaminados com saliva e sangue. Foram utilizados molares humanos saudáveis e os espécimes e as coroas foram seccionados na direção bucal-lingual, obtendo assim dois segmentos de proporções semelhantes (mesial e distal), totalizando 60 superfícies, e as superfícies foram divididas aleatoriamente em 4 grupos (n = 15). O Grupo I (controle) não recebeu nenhum tipo de contaminação e o selante foi aplicado. No grupo II, as superfícies foram contaminadas com 10 μl de saliva / sangue e o selante foi aplicado. No grupo III, as superfícies foram contaminadas com 10 μl de saliva / sangue e o sistema adesivo Single-Bond foi aplicado seguindo a aplicação de selante. No grupo IV, as superfícies foram contaminadas com 10 μl de saliva / sangue e o sistema adesivo de ataque total Prime & Bond NT foi aplicado seguido da aplicação de vedante. As amostras foram testadas na máquina de ensaio universal e a análise da resistência à ligação ao cisalhamento foi realizada. Uma diferença entre o Grupo I (12,61MPa) e os outros grupos foi encontrada; O Grupo II (2,28 MPa) foi diferente dos Grupos III (7,07MPa) e IV (7,79 MPa), mas os Grupos III e IV foram semelhantes. A aplicação de um sistema adesivo quando existe contaminação com saliva / sangue é necessária antes da aplicação de selantes de fissura e fissura.. Palavras-chave: Selantes de Fossas e Fissuras. Contaminação Biológica. Resistência ao Cisalhamento.


2014 ◽  
Vol 08 (02) ◽  
pp. 184-190 ◽  
Author(s):  
Dina Wafik Elkassas ◽  
Elham Mostafa Fawzi ◽  
Ahmed El Zohairy

ABSTRACT Objectives: This study was carried out to examine the effect of application of four different disinfecting agents on the micro-shear bond strength (μ-SBS) of an etch-and-rinse and self-etch adhesive systems. Materials and Methods: One hundred flat dentin surfaces of human molars were produced by wet grinding the buccal surfaces. Specimens were randomly assigned to five groups according to the disinfectant used: Group I: Control (no disinfectant); Group II: 5.25% sodium hypochlorite based; Group III: 2% chlorhexidine based (Consepsis), Group IV: 0.1% benzalkoniumchloride based (Tubulicid red) and Group V: 3% doxycycline based (Biopure, MTAD). Specimens were bonded using either Adper Single Bond 2 or Clearfil S3 Bond, which were employed according to the manufacturer's instructions. Resin composite microcylinders were bonded using Tygon® tubes for μ-SBS testing. The modes of failure were noted after visual examination using a binocular stereomicroscope at ×25 magnification. Failures were classified as adhesive, or mixed. μ-SBS results were analyzed using two-way ANOVA followed by Tukey's post-hoc test. Results: Dentin disinfectants tested significantly negated the bonding of Adper Single bond 2 and the groups were ranked; Group I > Group V = Group IV > Group II = Group III, meanwhile they enhanced significantly the μ-SBS values upon using Clearfil S3 Bond and were ranked; Group II > Group III = Group IV = Group V > Group I. Most failures were adhesive with the Adper single bond adhesive system. Mixed modes of failure were evident with Clearfil S3 bond. Conclusions: The disinfectants tested should not be used with Adper Single Bond 2 when applied before the etching step, However they could be used safely prior to bonding with Clearfil S3 Bond.


2012 ◽  
Vol 17 (4) ◽  
pp. 1-7 ◽  
Author(s):  
Roberto Hideo Shimizu ◽  
Karlos Giovani Grando ◽  
Isabela Almeida Shimizu ◽  
Augusto Ricardo Andriguetto ◽  
Ana Cláudia Moreira Melo ◽  
...  

OBJECTIVE: This in vitro study was designed to evaluate the shear bond strength (SBS) of orthodontic metal brackets bonded by direct and indirect techniques. METHODS: Thirty healthy human maxillary premolar teeth were used. The teeth were divided into three groups of 10 teeth each: Group I - indirect bonding with SondhiTM Rapid-Set system (3M/Unitek), Group II - indirect bonding with TransbondTM XT adhesive system (3M/Unitek) and Group III - direct bonding with TransbondTM XT adhesive system (3M/Unitek). After bonding and obtaining the specimens for the study, the specimens were subjected to SBS testing in a universal testing machine (Emic, model DL-500). The Kolmogorov-Smirnov test was applied to ascertain that the data had a normal distribution and the Bartlett test to check whether there was homogeneity of variance. One-factor analysis of variance was performed and, subsequently, Tukey's test for paired means. A 5% significance level was adopted. RESULTS: The results of Group I were 67.6 (N) and 5.9 (MPa); Group II, 68.9 (N) and 6.1 (MPa) and Group III (control), 92.5 (N) and 8.1 (MPa). CONCLUSION: It can therefore be concluded that the means for Group III were significantly higher compared with Groups I and II in both Newton (N) and Megapascal (MPa) values. The means attained by the indirect bonding technique used in Groups I and II, however, exhibited no statistically significant differences.


2019 ◽  
Vol 7 (13) ◽  
pp. 2162-2166 ◽  
Author(s):  
Rasha M. Abdelraouf ◽  
Manar Mohammed ◽  
Fatma Abdelgawad

AIM: This study aimed to assess the shear bond strength of a self-adhering flowable resin composite versus a total-etch one to different surfaces of permanent-molars. MATERIAL AND METHODS: Thirty-six sound human permanent molars were used. The teeth were embedded in acrylic blocks, such that their buccal surfaces were shown. The teeth were divided into three groups: Group I: Uncut-Enamel, Group II: Cut-enamel-surfaces with minimal-grinding and Group III: dentin-surfaces. Half of the teeth in each group were used for bonding to a self-adhering flowable resin-composite (Dyad-flow, Kerr, USA). While the other half of each group was bonded to a total-etch flowable resin-composite (Filtek™Z350-XT,3M-ESPE, USA) which necessitate etching and bonding. Teflon-mold was used for constructing resin composite cylinders (3 × 3 mm) over the buccal surfaces. The Dyad-flow was applied in the central hole of the mould placed upon tooth-surface, and then light-cured for 20 seconds. The Filtek-Z350-XT was applied similarly after etching and bonding steps. The teeth were stored in 37°C distilled water for 24 hours. The strength was measured using a universal testing machine and statistically analysed. Modes of failure were studied using digital-microscope. RESULTS: Mean values of shear bond strength for the Dyad and Filtek-Z350-XT in the uncut-enamel were 3.5 and 24.6MPa respectively, while that for cut-enamel were 4.5 and 12.7MPa respectively (Both highly statistically significant P ≤ 0.01) and in dentin were 4.3 and 6.7MPa respectively (Statistically significant P ≤ 0.05). The failure mode for Dyad was mainly adhesive (un-cut or cut-enamel 83.3% adhesive and 16.7% mixed, while in dentin 100% adhesive). While the modes of failure for Filtek-Z350-XT in enamel, either cut or un-cut, were 50% cohesive and 50% mixed, whereas in dentin 100% adhesive. CONCLUSION: Bonding of self-etch ″Dyad-flow″ flowable resin-composite was lower than the total-etch one in enamel and dentin. Thus further material improvement may be required.


2014 ◽  
Vol 13 (1) ◽  
pp. 7
Author(s):  
Dewi Puspitasari ◽  
Andi Soufyan ◽  
Ellyza Herda

Composite resin is a widely used aesthetic restoration. The restoration can fail due to secondary caries. Chlorhexidinegluconate 2% is used as a cavity disinfectant to eliminate microorganisms on the prepared cavity and to prevent thesecondary caries. The purpose of this study was to analyze the effect of chlorhexidine gluconate 2% to the bondstrength of composite resin with self etch system adhesive on dentine. Sixteen specimens of buccal dentine of premolarscrown are divided into 2 different groups. Group I: Clearfil SE Bond self-etch primer was applied for 20 seconds,Clearfil SE Bond bonding was applied for 5 seconds and polymerized for 10 seconds. Composite resin was constructedincrementally and polymerized for 20 seconds. Group II: prior to self etch primer application as in group I,chlorhexidine gluconate 2% was applied for 15 seconds. Shear bond strength was tested using Testing machine andanalyzed with unpaired T test. The highest shear bond strength was obtained by applying chlorhexidine gluconate 2%.The study concludes that chlorhexidine gluconate 2% application to dentine did not affect significantly to the bondstrength composite resin using self etch adhesive systems.


2013 ◽  
Vol 1 (4) ◽  
pp. 335
Author(s):  
Lorena Dos Santos Silva ◽  
Kátia Rodrigues Reis ◽  
Glaucia Maria Bovi Ambrosano ◽  
Fabíola Mendonça da Silva Chuí ◽  
Neylla Teixeira Sena ◽  
...  

The aim of this study was to evaluate the influence of three adhesive systems on resinous bonding of carbon fiber posts on roots of endodontically treated bovine incisors. Thirty bovine lower incisors with similar dimensions were selected for this study. The roots were endodontically treated and subsequently prepared for post cementation. The posts were treated with adhesive systems Scotchbond MultiPurpose Plus – 3M chemical cure (Group I), light cure (Group II) and dual cure (Group III). Carbon fiber posts were adjusted to 8mm and cemented in the canal with resinous dual cement RelyX ARC – 3M. Those were taken to Universal Essay Machine for the push-out shear bond strength test. Analysis of the results were made with 2-Way ANOVA and post-hoc with Tukey’s test (p<0.05). The groups were statistically different. The chemical cure adhesive system (Group I) showed highest values of resistance to push-out, both at all thirds as well as in total average (24.77 MPa), followed by light cure adhesive (Group II, 22.26 MPa), and dual cure (Group III, 18.38 MPa). Scothbond Multi-Purpose Plus – 3M adhesive system presented highest shear bond strength on resinous cementation of carbon posts to root dentin, and therefore is the first choice among the materials presented in this study.


2015 ◽  
Vol 5 (3) ◽  
pp. 153-157
Author(s):  
Manoj Hans ◽  
Abhinav Sharma ◽  
Shashit Shetty

ABSTRACT Background The purpose of this study was to evaluate the shear bond strength (SBS) of two different adhesives to normal and deproteinized dentin at an interval of 24 hours and 6 months. Materials and Methods Sixty human molars were sectioned and embedded in acrylic resin. Enamel was worn out and dentin was exposed over which acid etching was performed and the specimens were divided into 12 groups (n = 10) depending on the adhesive system used, the dentin treatment performed and the length of evaluation. A resin composite was inserted over the prepared area followed by assessment for shear bond strength evaluation. Results The application of Sodium hypochlorite (NaOCl) significantly increased the SBS values of prime and bond NT but for adper single bond it was decreased. The means values of SBS standard deviation (SD) in MPa for adhesive systems with 5% NaOCI for 60 seconds, 120 seconds and without NaOCl treatment were: prime and bond NT = 12.48 (1.25), 13.01 (1.00) and 17.74 (4.26) and for adper single bond = 10.92 (1.65), 10.96 (2.45) and 7.57 (1.45). Shear bond strength after storage time of 6 months was decreased significantly. Conclusion According to the statistical analysis, the results only partly supported the hypotheses and greatly depend on the composition of adhesive system. How to cite this article Sharma A, Shetty S, Hans M. Shear Bond Strength Evaluation of Two Adhesive Systems Applied to Etched and Deproteinized Dentin: A Longitudinal Study. J Contemp Dent 2015;5(3):153-157.


2012 ◽  
Vol 3 (2) ◽  
pp. 176-179
Author(s):  
Daphne Câmara Barcellos ◽  
Cesar Rogério Pucci ◽  
Maria Filomena Rocha Lima Huhtala ◽  
Eduardo Bresciani ◽  
Daniel Gomes Duarte ◽  
...  

ABSTRACT Purpose The objective of this study was to evaluate the influence of the Grander technology on the shear bond strength of total-etch adhesive system Single Bond 2 to dentin. Materials and methods Forty bovine incisors were used. They were sectioned and the buccal surfaces worn down with abrasive paper. Acid etching was performed, and the specimens were divided into two groups (n = 20): Group G1—Single Bond 2 adhesive system (3M ESPE) under normal conditions; group G2—Single Bond 2 adhesive system modified by physical contact for 48 hours with the flexible unit Grander system. The resin composite was inserted with the aid of a metallic matrix over the prepared area. After the mechanical shear test, data were submitted to the statistical t-test (5%). The t-test showed that the results for G1 and G2 were similar (p > 0.05). The mean values (± SD) were: G1—6.66 (± 2.40); G2—5.26 (± 2.15). Conclusion Grander technology did not influence the initial shear bond strength of the Single Bond 2 adhesive system to dentin. How to cite this article Duarte DG, de Paiva Gonçalves SE, Barcellos DC, Huhtala MFRL, Bresciani E, Pucci CR. Evaluation of Shear Bond Strength of a Grander-Modified Adhesive System to Bovine Dentin. World J Dent 2012;3(2):176-179.


2021 ◽  
Vol 24 (2) ◽  
Author(s):  
Fateme Vasei ◽  
Farahnaz Sharafeddin

Objective: To assess the shear bond strength (SBS) of resin composite to deep dentin, using 1 and 2.5% chitosan pretreatment as well as different adhesive systems. Material and Methods: 80 human maxillary molars were randomly divided to eight groups according to the type of adhesive system and dentin pretreatment (n = 10): I) two-step self-etch system (Clearfil SE bond); II) two-step etch-andrinse system (Adper single bond 2); III) 2.5% chitosan + Clearfil SE bond; IV) 2.5% chitosan +etch + Adper single bond 2; V) etch + 2.5% chitosan + Adper single bond 2; VI) 1% chitosan + Clearfil SE bond; VII) 1% chitosan + etch + Adper single bond 2; VIII) etch + 1% chitosan + Adper single bond 2 (chitosan solution (w/v): 2.5 g and 1 g of chitosan (Sigma Aldrich, USA) was dissolved in 100 ml of 1% acetic acid). Plastic molds were positioned on dentin and filled with composite (Z350, 3M ESPE, USA). SBS (MPa) was tested using a universal testing machine. ANOVA tests, Tukey’s test, and independent t test were used to analyze data (p < 0.05). Results: The highest SBS value among self-etch groups was observed with 1% chitosan (p = 0.001). In the etch-and-rinse group, the SBS of 1% chitosan was significantly lower than the other groups. Chitosan treatment following acid etching led to higher SBS in comparison to when chitosan was applied before etching, with the significant difference in 1% concentration (p = 0.030). A predominance of mix fractures was observed in dentin. Conclusion: Improved dentin bond strength can be achieved through immediate dentin pretreatment with 1% chitosan in self-etch adhesive systems. Chitosan Pretreatment may not be advantageous for etch-and-rinse adhesive systems. Keywords Adhesive system; Chitosan; Deep dentin; Shear strength.