diffusion absorption
Recently Published Documents


TOTAL DOCUMENTS

141
(FIVE YEARS 39)

H-INDEX

20
(FIVE YEARS 3)

2021 ◽  
Vol 412 ◽  
pp. 27-36
Author(s):  
Bella Gurevich ◽  
Amir Zohar

In conventional vapor compression and absorption refrigeration systems, a compressor or a mechanical pump, respectively circulates the refrigerant. Mechanical input, which is required by the compressor or the pump operation, contributes significantly to the noise level and lessens its reliability and portability. In contrast, diffusion absorption refrigeration (DAR) systems are heat-driven and contain no moving parts. Solar-driven diffusion absorption cooling system uses a low-grade heat to produce a cooling effect, and it's specially tuned for remote locations with high levels of solar radiation. This article studies the performance of a DAR system in Ashdod, Israel. Based on existing models in the literature and on experimental measurement of quantities such as the solar irradiance and the air temperature, the cooling capacity and the COP were simulated. Cooling capacity of the DAR system varies between 100 and 140 W, and COP between 0.09 and 0.17.


2021 ◽  
Vol 9 ◽  
Author(s):  
Shuai Du

Ammonia water absorption refrigeration systems are effective in utilizing fishing-boat exhaust waste heat for cryopreservation. However, the liquid level control and the use of a solution pump characterized by small flowrate and high-pressure head result in poor reliability in the traditional system. Besides, the system must necessarily be designed anti-swaying and anti-corrosion. This paper proposes a forced flow diffusion absorption refrigeration system, in which an inherently leak-free canned motor pump and an ejector are employed to provide the driving forces of the gas and liquid loops. The approximate single pressure operation allows for a simple passive liquid sealing control without throttling valves. The system adopts an integrated cooling strategy which allows the system to operate under swaying conditions, and the external seawater cooled heat exchanger avoids internal corrosion and leakage. The thermal analysis shows the system is valid to be operated under wide operating conditions, and the coupled gas and solution circulation ratios determined the performance of the novel system. There is an optimal ammonia mass fraction difference in the gas loop to obtain the optimal COP. The COP reaches 0.4 when the temperatures at the outlets of the generator, evaporator, absorber, and condenser are 160, −15, 35, and 35°C, respectively. The novel system provides a reliable absorption refrigeration system design for fishing-boat applications.


Author(s):  
Noman Yousuf ◽  
Timothy Anderson ◽  
Roy Nates

Abstract Despite being identified nearly a century ago, the diffusion absorption refrigeration (DAR) cycle has received relatively little attention. One of the strongest attractions of the DAR cycle lies in the fact that it is thermally driven and does not require high value work. This makes it a prime candidate for harnessing low grade heat from solar collectors, or the waste heat from stationary generators, to produce cooling. However, to realize the benefits of the DAR cycle, there is a need to develop an improved understanding of how design parameters influence its performance. In this vein, this work developed a new parametric model that can be used to examine the performance of the DAR cycle for a range of operating conditions. The results showed that the cycle's performance was particularly sensitive to several factors: the rate of heat added and the temperature of the generator, the effectiveness of the gas and solution heat exchangers, the mass flowrate of the refrigerant and the type of the working fluid. It was shown that can deliver good performance at low generator temperatures if the refrigerant mass fraction in the strong solution is made as high as possible. Moreover, it was shown that a H2O-LiBr working pair could be useful for achieving cooling at low generator temperatures.


2021 ◽  
Vol 380 ◽  
pp. 113807
Author(s):  
Albert Puigferrat ◽  
Miguel Masó ◽  
Ignasi de-Pouplana ◽  
Guillermo Casas ◽  
Eugenio Oñate

2021 ◽  
Vol 8 (2) ◽  
pp. 253-258
Author(s):  
Djallel Zebbar ◽  
Souhila Zebbar ◽  
Sahraoui Kherris ◽  
Kouider Mostefa

This paper is consecrated to the thermodynamic study and analysis of diffusion-absorption-refrigeration (DAR) plants. The mass and energy balances analysis at the evaporator has allowed to highlight a new and original parameter, which can be used to analyze DAR system performances. It is the ratio of inert gas to refrigerant vapor mass flow rates at the evaporator inlets. This coefficient, which expression has been for the first time deduced mathematically, informs about the quality of the cycle and its performance, which are deeply affected by the growth of the inert gas flow energy expended to drive the refrigerant through the evaporator. The study shows that the coefficient of performance is decreasing with the increase of the mass flow rates ratio. The latter can be also used to find the optimal operating mode for the DAR machine with a specified working fluid.