pressure drops
Recently Published Documents


TOTAL DOCUMENTS

1231
(FIVE YEARS 279)

H-INDEX

46
(FIVE YEARS 5)

Energies ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 400
Author(s):  
Miftah Altwieb ◽  
Rakesh Mishra ◽  
Aliyu M. Aliyu ◽  
Krzysztof J. Kubiak

Multi-tube multi-fin heat exchangers are extensively used in various industries. In the current work, detailed experimental investigations were carried out to establish the flow/heat transfer characteristics in three distinct heat exchanger geometries. A novel perforated plain fin design was developed, and its performance was evaluated against standard plain and louvred fins designs. Experimental setups were designed, and the tests were carefully carried out which enabled quantification of the heat transfer and pressure drop characteristics. In the experiments the average velocity of air was varied in the range of 0.7 m/s to 4 m/s corresponding to Reynolds numbers of 600 to 2650. The water side flow rates in the tubes were kept at 0.12, 0.18, 0.24, 0.3, and 0.36 m3/h corresponding to Reynolds numbers between 6000 and 30,000. It was found that the louvred fins produced the highest heat transfer rate due to the availability of higher surface area, but it also produced the highest pressure drops. Conversely, while the new perforated design produced a slightly higher pressure drop than the plain fin design, it gave a higher value of heat transfer rate than the plain fin especially at the lower liquid flow rates. Specifically, the louvred fin gave consistently high pressure drops, up to 3 to 4 times more than the plain and perforated models at 4 m/s air flow, however, the heat transfer enhancement was only about 11% and 13% over the perforated and plain fin models, respectively. The mean heat transfer rate and pressure drops were used to calculate the Colburn and Fanning friction factors. Two novel semiempirical relationships were derived for the heat exchanger’s Fanning and Colburn factors as functions of the non-dimensional fin surface area and the Reynolds number. It was demonstrated that the Colburn and Fanning factors were predicted by the new correlations to within ±15% of the experiments.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8396
Author(s):  
Tadeusz Dziubak

In this paper, the uneven air stream distribution problem of individual cyclones is studied in the multi-cyclones of intake air filters in special vehicles’ engines. This problem increases in multi-cyclones, in which several dozen cyclones have a common dust trap from which the collected dust is continuously removed by ejection suction. The aim of this study is the recognition of the theoretical and experimental possibility of reducing the streams’ unevenness, which should result in an efficiency increase in multi-cyclone separation. The methods that led to obtaining a relative stream uniformity from the suction of individual cyclones was analyzed. The method for creating equal pressure drops between the suction streams in the channels was used to achieve this goal. For this purpose, the internal structure of the multi-cyclone settler was changed. The multi-cyclone settling tank space was divided by vertical partitions into independent segments. The settling tank segment was then divided with horizontal shelves into suction channels of different heights, which were assigned a specific number of individual cyclones. The suction channels’ height was theoretically selected in terms of the equal resistance to air stream flow through the channels. For this purpose, the multi-cyclone dust settler segment model was developed. The theoretically determined suction channel’s height was verified by performing experimental flow tests in four (A, B, C, D) dust settler variants. Suction streams of satisfactory uniformity from the cyclones of the variant D settling tank were obtained at a level of 5%. In the next stage, experimental tests of the segment cyclones were carried out with dust before and after the division into suction channels of variant D for the settling tank. A significant increase was achieved from 93.73% to 96.08% in the cyclones’ separation efficiency, which were located as far away from the suction stub as possible and led to a reduction in the non-uniformity of cyclone efficiency in the segment. It follows that the multi-cyclone dust settling segment’s internal structure change gave the expected results.


JTAM ROTARY ◽  
2021 ◽  
Vol 3 (2) ◽  
Author(s):  
Ilham Arif Firmansyah ◽  
Aqli Mursadin

Supply of compressed air has an important role in continuity of operation power plant, failures that occur in operation of engine in this unit can affect all plant operations that can result in decreased production levels. To determine the magnitude of loss of pressure or energy loss lost in pressurized air piping system at plant located in PT. Indocement Tunggal Prakarsa, Tbk. Tarjun Plant-12. Evaluation of pressure reduction losses in the air system is focused on losses caused by system leakage and pressure drops in the distribution lines caused by several factors including friction in straight pipes, bends, fittings, reducers and existing components, and knowing the loss of costs due to compressor pressure drop. The pressure drop in the pipe is very dependent on pipe diameter, besides distance and supporting components on piping system also affect the pressure drop. Based on calculation, there was a decrease in pressure of 1603660,895 Pa, from pressure drop caused by friction of straight pipe and connection and actual condition of pipe surface which was likely to have been corroded, making surface rough. system decline that occurred in the compressor resulted in a loss of operational costs of 5,760,451 rupiah / week.


2021 ◽  
Vol 13 (24) ◽  
pp. 13643
Author(s):  
Seung-Hoon Park ◽  
Jae-Hun Jo ◽  
Eui-Jong Kim

With increasing global concerns regarding indoor air quality (IAQ) and air pollution, concerns about regularly replacing ventilation devices, particularly high-efficiency particulate air (HEPA) filters, have increased. However, users cannot easily determine when to replace filters. This paper proposes models to estimate the dust loading levels of HEPA filters for an energy-recovery ventilation system that performs air purification. The models utilize filter pressure drops, the revolutions per minute (RPM) of supply fans, and rated airflow modes as variables for regression equations. The obtained results demonstrated that the filter dust loading level could be estimated once the filter pressure drops and RPM, and voltage for the rated airflow were input in the models, with a root mean square error of 5.1–12.9%. Despite current methods using fewer experimental datasets than the proposed models, our findings indicate that these models could be efficiently used in the development of filter replacement alarms to help users decide when to replace their filters.


2021 ◽  
Author(s):  
Alfredo Freites ◽  
Victor Segura ◽  
Muhammad Muneeb

Abstract Maximum Reservoir Contact wells (MRCs) are a potential alternative to reduce the number of wells required to develop hydrocarbon reservoirs, improve sweeping efficiency and delay gas and water breakthrough. The well completions design is critical for the success of MRCs. In this study we present a case study of a MRC well completion design using Limited Entry Liners (LEL) in a mature carbonate reservoir under water and miscible gas injection. We developed an integrated workflow that considered a high-resolution numerical simulation model calibrated to static and dynamic data and wellbore-reservoir models coupling, for capturing the details of the flow interaction between both systems. Flow restrictions in the form of additional pressure drops to the flow from the reservoir into the wellbore were used to simulate the effect of small open flow areas, i.e.shot densities, in the LELs. Our work allowed identifying the most likely entry points of gas and water and design the well to minimize their impact on oil production. We observe that longer lengths open to flow outweighs the detrimental effect of producing from intervals closer to the water saturated zones. We also observed that balancing the inflow profile along the wellbore did not report beneficial results to oil production as it stimulates production from the reservoir zone from which the gas breakthrough is expected (middle of the producing section); this result is particularly relevant as it shows that designing the well completions with base only on static data could lead to poor production performance. The suggested completion for the MRC well encompasses four segments; a segment covering almost 50 % of the well length and located at the middle of the producing section with a blind liner (close to flow for gas control) and the remaining three with slotted liners with enough open area as to avoid causing significant pressure drops.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8249
Author(s):  
Xuchen Fan ◽  
Xiaofeng Lu ◽  
Jiping Wang ◽  
Zilong Li ◽  
Quanhai Wang ◽  
...  

The use of the Maisotsenko cycle (M-Cycle) in traditional wet cooling towers (TWCTs) has the potential to reduce the costs of electricity generation by cooling water below the inlet air’s wet-bulb temperature. TWCTs cannot provide sufficient cooling capacity for the increasing demand for cooling energy in the power and industrial sectors—especially in hot and wet climates. Due to this fact, an experimental system of an M-Cycle cooling tower (MCT) with parallel counter-flow arrangement fills was constructed in order to provide perspective on the optimal length of dry channels (ldry), thermal performance under different conditions, and pressure drops of the MCT. Results showed that the optimal value of ldry was 2.4 m, and the maximum wet-bulb effectiveness was up to 180%. In addition, the impact of air velocity in wet channels on the pressure drops of the novel fills was also summarized. This study confirms the great potential of using the M-Cycle in TWCTs, and provides a guideline for the industrial application and performance improvement of MCTs.


2021 ◽  
Vol 11 (23) ◽  
pp. 11361
Author(s):  
Abdulgaphur Athani ◽  
Nik Nazri Nik Ghazali ◽  
Irfan Anjum Badruddin ◽  
Abdullah Y. Usmani ◽  
Sarfaraz Kamangar ◽  
...  

Coronary artery disease (CAD) is stated as one of the most common causes of death all over the world. This article explores the influence of multi stenosis in a flexible and rigid left coronary artery (LCA) model using a multiphase blood flow system which has not yet been studied. Two-way fluid–solid interaction (FSI) is employed to achieve flow within the flexible artery model. A realistic three-dimensional model of multi-stenosed LCA was reconstructed based on computerized tomography (CT) images. The fluid domain was solved using a finite volume-based commercial software (FLUENT 2020). The fluid (blood) and solid (wall) domains were fully coupled by using the ANSYS Fluid-Structure Interaction solver. The maximum pressure drops, and wall shear stress was determined across the sever stenosis (90% AS). The higher region of displacement occurs at the pre-stenosis area compared to the other area of the left coronary artery model. An increase in blood flow velocity across the restricted regions (stenosis) in the LCA was observed, whereas the recirculation zone at the post-stenosis and bifurcation regions was noted. An overestimation of hemodynamic descriptors for the rigid models was found as compared to the FSI models.


2021 ◽  
Vol 947 (1) ◽  
pp. 012008
Author(s):  
Trung Kim Nguyen ◽  
Tuan Nguyen Ba ◽  
Pha Bui Ngoc ◽  
Abdul Mutalib Embong ◽  
Ngoc Nguyen Thi Nhu ◽  
...  

Abstract The aim of this paper is to propose a model to simulate the behaviour of water flows in shell and tube heat exchanger. Particularly, the continuity equation, the general heat transfer equations and the energy equation in COMSOL Multiphysics software were implemented in the numerical modelling. Besides, the experiment was also conducted to validate the proposed COMSOL model. The water temperature at locations close to the inlet and outlet of the shell side was respectively predicted at 31.5°C and 34.6°C in the simulation, and it was respectively measured at 31.5°C and 35°C in the experiment. These findings showed that the simulation results had a good agreement with the experiment. Next, this model was extended to simulate the overall heat coefficient and the pressure drops of the water flows in such heat exchanger. The overall heat coefficient was at 736.62 W/m2K. The pressure drops at the inlet/outlet areas of the shell and tubes were at 849.93 Pa and 6255.50 Pa, respectively. Conclusive evidence showed that the proposed model is a reliable method for studying the heat transfer behaviour of the shell and heat exchanger.


2021 ◽  
Vol 24 (1) ◽  
pp. 25-32
Author(s):  
Mykola Karpenko ◽  
Olegas Prentkovskis ◽  
Šarūnas Šukevičius

Reliability and maintenance analysis of transport machines hydraulic drives, basically focused to power units: pumps, cylinders etc., without taking in to account junction elements. Therefore, this paper proposes a research analysis on high-pressure hoses and junctions during technical maintenance. Comparative analysis of fluid behavior and energy efficiency inside non-repaired and repaired high-pressure hoses is presented in this research. Theoretical and experimental research results for hydraulic processes inside high-pressure hose is based on the numerical simulations using Navier–Stokes equations and experimental measurement of fluid flow pressure inside high-pressure hoses. Research of fluid flow dynamics in the hydraulic system was made with main assumptions: system flow rate in the range from 5 to 100 l/min, diameter of the hoses and repairing fitting are 3/8". The pressure drops, power losses, flow coefficients at non-repaired and after maintenance hose was obtained as a result. Simulation results were verified by running physical experiments to measure the pressure losses.


2021 ◽  
Vol 2 (2) ◽  
pp. 87
Author(s):  
Muhammad Zakiy Yusrizal ◽  
Anas Puji Santoso

The ability of the reservoir to deliver a certain quantity of gas depends both on the inflow performance relationship and the flowing bottom hole pressure. In order to determine the deliverability of the total well system, it is necessary to calculate all the parameters and pressure drops, one of which in the tubing. Calculation of pressure loss in the tubing is a very important parameter in the stability of fluid flow from the reservoir to the surface. The calculation of pressure loss in the tubing which is most widely used in the field is the Cullender and Smith Method. The purpose of this study is to validate why the Cullender and Smith method is most widely used in the field to determine the pressure loss in the tubing compared to other pressure loss in tubing methods. The methodology used in this study is calculating the pressure loss in the tubing with the Average Temperature and Deviation Factor Method, the Sukkar and Cornel Method, and the Cullender and Smith Method. After calculating the pressure loss in the tubing using each of these methods, then comparing the percent error of the calculation method with the results in the well. The data used in the calculation is the data from the MZ Field from 7 wells in the East Kalimantan area. The results of the average error percentage obtained from this study are the Average and Deviation Factor Method is 5.38%, the Sukkar and Cornell Method is 5.65%, and the Cullender and Smith Method is 3.83%. From this study, it can be said that the Cullender and Smith Method to be valid or the most accurate method for used in the field compared to other methods due to resulting the smallest percent error from the calculation.


Sign in / Sign up

Export Citation Format

Share Document