contrast ratio
Recently Published Documents


TOTAL DOCUMENTS

728
(FIVE YEARS 226)

H-INDEX

34
(FIVE YEARS 8)

2022 ◽  
Vol 14 (2) ◽  
pp. 403
Author(s):  
Chongdi Duan ◽  
Yu Li ◽  
Weiwei Wang ◽  
Jianguo Li

With the rapid development of cooperative detection technology, target fusion detection with regard of LEO satellites can be realized by means of their diverse observation configurations. However, the existing constant false alarm ratio (CFAR) detection research rarely involves the space-based target fusion detection theory. In this paper, a novel multi-source fusion detection method based on LEO satellites is presented. Firstly, the pre-compensation function is constructed by employing the range and Doppler history of the cell where the antenna beam center is pointed. As a result, not only is the Doppler band broadening problem caused by the high-speed movement of the satellite platform, but the Doppler frequency rate (DFR) offset issue resulted from different observation configurations are alleviated synchronously. Then, the theoretical upper and lower limits of DFR are designed to achieve the effective clutter suppression and the accurate target echo fusion. Finally, the CFAR detection threshold based on the exponential weighted likelihood ratio is derived, which effectively increases the contrast ratio between the target cell and other background cells, and thus to provide an effective multi-source fusion detection method for LEO-based satellite constellation. Simulation results verify the effectiveness of the proposed algorithm.


2022 ◽  
Author(s):  
Osman Cifci ◽  
Mikayla Yoder ◽  
Lu Xu ◽  
Hao Chen ◽  
Christopher Beck ◽  
...  

Abstract A key display characteristic is its efficiency (emitted light power divided by input power). While display efficiencies are being improved through emissive (e.g., quantum dot and organic light emitting display (OLED) designs1,2, which remove the highly inefficient color filters found in traditional liquid crystal displays (LCDs)3,4, polarization filters, which block about 50% of the light, remain required to inhibit ambient light reflection. We introduce a luminescent cavity design to replace both the color and polarization filters. Narrow-band, large Stokes shift, CdSe/CdS quantum dot emitters are embedded in a reflective cavity pixel element with a small top aperture. The remainder of the top surface is coated black reducing ambient light reflection. A single pixel demonstrates an extraction efficiency of 40.9% from a cavity with an 11% aperture opening. A simple proof-of-concept multi-pixel array is demonstrated.


2022 ◽  
Vol 54 (2) ◽  
Author(s):  
R. Arunkumar ◽  
V. Kavitha ◽  
K. Rama Prabha ◽  
K. Latha ◽  
S. Robinson

Author(s):  
Gregor F. H. Indorf ◽  
Graeme G Scott ◽  
Malte A. Ennen ◽  
Pierre Forestier-Colleoni ◽  
David Haddock ◽  
...  

Abstract The interaction of very intense and ultrashort laser pulses with solid targets is a topic that has attracted a large amount of interest in science and applications. This interest is boosted by the large progress made in the development of high repetition rate, high-power laser systems. With the significant increase in average power, there is concern about how to deal with ablated debris that may lead to contamination and damage during interaction experiments with solid targets. This issue is also highly relevant in experiments that include plasma mirrors. These are often employed to increase the contrast ratio of the intense laser pulse to unwanted laser pre-pulses from the amplifier chain and/or the background of amplified spontaneous emission. For this reason, the present work investigates the mass ejected from the target into vacuum for different conditions, particularly those present when plasma mirrors are introduced. The total amount of ablated mass can be reduced by making use of a temporally controlled plasma expansion that enhances the plasma mirror reflectivity. In this way, high intensity laser interaction experiments can be carried out with efficient and clean plasma mirrors significantly reducing the degradation of the laser optics and plasma diagnostics placed near the interaction.


2022 ◽  
Vol 12 (2) ◽  
pp. 560
Author(s):  
Chang-Lin Hu ◽  
Chien-Ju Li ◽  
I-Cheng Cheng ◽  
Peng-Zhi Sun ◽  
Brian Hsu ◽  
...  

Handheld ultrasound devices have been widely used for diagnostic applications. The use of the acoustic-field beamforming (AFB) method has been proposed for handheld ultrasound to reduce electricity consumption and avoid battery and unwanted heat issues. However, the image quality, such as the contrast ratio and contrast-to-noise-ratio, are poorer with this technique than with the conventional delay-and-sum method. To address the problems associated with the worse image quality in AFB imaging, in this paper we propose the use of an AFB-based generalized coherence factor (GCF) technique, in which the GCF weighting developed for adaptive beamforming is extended to AFB. Simulation data, experimental results, and in vivo testing verified the efficacy of our proposed AFB-based GCF technique.


Author(s):  
Riku Suzuki ◽  
Ryo Shintate ◽  
Takuro Ishii ◽  
Yoshifumi Saijo

Abstract To achieve fine visualization of the peripheral microvascular networks, we have developed a photoacoustic (PA) microscope equipped with a four-channel annular array transducer. The quality of PA images processed with Delay-and-Sum (DAS) method is degraded by off-axis signals. Thus, to achieve higher image quality for the PA microscope, this study evaluated the efficacy of the five coherence factor weighting methods: coherence factor, sign coherence factor, phase coherence factor, circular coherence factor, and vector coherence factor. Using PA signals acquired from a 100 µm microtube and the skin microvessels, we generated PA images with DAS and one of the weighting methods, and quantitatively evaluated the image quality by calculating the sharpness, contrast ratio, and contrast-to-noise ratio. The results showed the phase coherence factor and the vector coherence factor methods were more effective to clearly visualize the microvascular structure, in terms of vessel sharpening and noise suppression performances, than the other methods.


Nano Research ◽  
2021 ◽  
Author(s):  
Jianxia Jiang ◽  
Leiqiang Qin ◽  
Joseph Halim ◽  
Per O. Å. Persson ◽  
Lintao Hou ◽  
...  

AbstractElectrochromic (EC) materials that change color with voltage have been widely studied for use in dynamic windows. However, colorless-to-colorful switching with high contrast ratio is generically unattainable, especially for colorless-to-black electrochromic materials with an ultrahigh contrast ratio over the entire visible region. In this work, we developed Nb1.33C MXene-based dynamic windows with colorless-to-black switching of up to 75% reversible change in transmittance from 300 to 1,500 nm. By exploring the electrochromic effects of different electrolytes through in situ optical changes and electrochemical quartz crystal microbalance (EQCM), it is found that electrochromic behavior is greatly influenced by the extent of reversible Li+ insertion/deinsertion between the two-dimensional Nb1.33C MXene nanosheets. In addition, a colorless-to-black EC device based on Nb1.33C with an overall integrated contrast ratio over 80% was successfully constructed by a solution-processable spin coating method. This work enables a simple route to fabricate MXene-based high-performance electrochromic smart windows, which is important for further expanding the application of MXenes to optoelectronic and photonic applications.


Author(s):  
Chaimongkon Peampring ◽  
Santiphab Kengtanyakich

Abstract Objective This study investigated the effect of hydrothermal aging on surface roughness and translucency of various translucent zirconia materials. Materials and Methods Four types of zirconia were tested. Group 1 was translucent zirconia with no cubic structure. Group 2, 3, and 4 included cubic-containing zirconia with different amounts of cubic structures (less than 30%, 30–50%, and more than 50%, respectively). Each group contained 15 disk-shape specimens with dimensions of 15 mm in diameter and 1 mm in thickness. As-sintered surface roughness, translucency parameter, and contrast ratio were evaluated in the two different sessions, before and after aging. Statistical Analysis Two-way repeated measures ANOVA with Bonferroni test was used to analyze statistically significant difference in those tested parameters. Phase structure before and after aging was analyzed by X-ray diffraction analysis (XRD). Results Groups 1 and 2 showed significant increased surface roughness after aging while groups 3 and 4 showed no alteration of surface. There was no effect of aging on translucency in all groups. After aging, group 1 and 2 presented monoclinic structure (16.63 and 5.01%, respectively). Conclusion Hydrothermal aging caused phase transformation and increasing surface roughness in group 1 and 2 but did not affect translucency in all groups.


Sign in / Sign up

Export Citation Format

Share Document